Reed Wittman

Dr. Reed Wittman


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2020 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
RWReed Wittman
Reed Wittman
MPMike L. Perry
Mike L. Perry
TLTimothy Lambert
Timothy Lambert
BCBabu R. Chalamala
Babu R. Chalamala
YPYuliya Preger
Yuliya Preger
Li-ion batteries currently dominate electrochemical energy storage for grid-scale applications, but there are promising aqueous battery technologies on the path to commercial adoption. Though aqueous batteries are considered lower risk, they can still undergo problematic degradation processes. This perspective details the degradation that aqueous batteries can experience during normal and abusive operation, and how these processes can even lead to cascading failure. We outline methods for studying these phenomena at the material and single-cell level. Considering reliability and safety studies early in technology development will facilitate translation of emerging aqueous batteries from the lab to the field.

1 December 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
RWReed Wittman
Reed Wittman
MDMatthieu Dubarry
Matthieu Dubarry
SISergei Ivanov
Sergei Ivanov
BJBenjamin W. Juba
Benjamin W. Juba
Jessica KustasJessica Kustas
Jessica Kustas
YPYuliya Preger
Yuliya Preger
Lithium-ion batteries are widely used in applications from consumer electronic devices to stationary energy storage. Appropriate management of batteries is challenging due to limited data on their performance and materials degradation. Previous studies have focused on characterization of single cells under specific operating conditions. In the present work, commercial 18650 lithium-ion cells with LiNixMnyCo1-x-yO2 (NMC) and LiNixCoyAl1-x-yO2 (NCA) positive electrodes were characterized by a wide range of electrochemical and materials techniques after cycling at 15, 25, or 35 °C to ∼80% capacity. The NCA cells exhibit weak temperature dependence in their cycle aging and materials degradation. The NMC cells exhibited increased capacity fade and materials degradation as ambient temperature decreased. All cells exhibited loss of lithium inventory as their primary degradation mode. However, the NCA cells only showed evidence of solid electrolyte interphase (SEI) growth whereas the NMC cells showed signs of Li plating at 15 °C, transitioning to SEI growth at 35 °C. The NMC cells displayed signs of loss of active material at the positive electrode at lower temperatures, suggesting that Li plating is correlated to additional processes that increase the rate of degradation. These results highlight the importance of avoiding broad generalizations about Li-ion battery temperature dependence.

10 March 2023 in ACS Applied Energy Materials
Verified
Journal Article
Open access
RWReed Wittman
Reed Wittman
CPCassandria Poirier
Cassandria Poirier
HPHarry D. Pratt
Harry D. Pratt
TATravis M. Anderson
Travis M. Anderson
YPYuliya Preger
Yuliya Preger

11 July 2025 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
YPYuliya Preger
Yuliya Preger
MFMax Feinauer
Max Feinauer
LTLoraine Torres-Castro
Loraine Torres-Castro
CHChristin Hogrefe
Christin Hogrefe
LGLucas S Gray
Lucas S Gray
TWThomas Waldmann
Thomas Waldmann
Understanding the safety profile of aged Li-ion batteries is essential for developing effective battery management and hazard mitigation strategies. However, most safety assessments have focused on fresh batteries, with just a few calorimetry studies on aged batteries with metal oxide positive electrodes. This study provides a broad assessment of commercial 18650-type Li-ion batteries with NCA, NMC, and LFP positive electrodes, both uncycled and aged under conditions that promoted solid electrolyte interphase (SEI) growth as the dominant degradation mechanism. The cells underwent mechanical (nail penetration, crush), electrical (overcharge, overdischarge), and thermal (accelerating rate calorimetry) abuse tests. Safety was rated on general characteristics such as mass loss, maximum temperature, and EUCAR (European Council for Automotive R&D) hazard level, as well as characteristics specific to individual abuse tests. Generally, aged cells with SEI growth exhibited similar or improved safety compared to uncycled cells, contrasting with our previous findings on NCA cells with Li plating as the dominant aging mechanism (Part I of this series). Yet, some tests and characteristics indicated reduced aged cell safety, such as earlier triggering of mechanical failure. These results emphasize the need to examine aged battery safety across diverse empirical techniques, degradation modes, and chemistries.

2 December 2021 in IEEE Electrification Magazine
Verified
Journal Article
Closed access
BCBabu R. Chalamala
Babu R. Chalamala
DRDavid Rosewater
David Rosewater
YPYuliya Preger
Yuliya Preger
RWReed Wittman
Reed Wittman
JLJoshua Lamb
Joshua Lamb
AKAkira Kashiwakura
Akira Kashiwakura
Energy storage systems are becoming widely deployed throughout the electricity infrastructure. Large-scale integration of energy storage systems will become much more widespread as we begin to integrate larger amounts of renewables. Furthermore, electrification of the transportation sector will demand fast charging infrastructure and energy storage to handle new loads on distribution systems. However, energy storage systems, especially battery energy storage systems (BESSs), present a range of hazards that make engineering safety of large-scale systems a challenge. This article explores engineering safety of grid energy storage systems from the perspective of an asset owner and system operator. We review the hazards of common lithium-ion and aqueous battery system designs along with the state-of-the-art hazard mitigation methods. We also summarize the development of codes and standards to ensure safety and discuss best practices for emergency preparedness.

3 December 2024 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
RWReed Wittman
Reed Wittman
RSRobert L. Sacci
Robert L. Sacci
RURaymond R. Unocic
Raymond R. Unocic
TZThomas A. Zawodzinski
Thomas A. Zawodzinski
In situ electrochemical Scanning Transmission Electron Microscopy (ec-S/TEM) probes the dynamics of electrochemical processes in real time and at high spatial resolution. This method utilizes microfabricated electrochemical cells, with enclosed dimensions of 800 μm wide, 800 μm long, and 1–2 μm tall, with electron-transparent silicon nitride windows. Working, counter, and reference electrodes in the configuration studied are deposited Pt with a planar surface area of about 1 μm2 and a height of 50 nm. The cell confines the electrolyte within a 1 μm tall channel, and the microfabricated electrodes have a non-standard geometry, are coplanar, and are not front-facing. As such, standard assumptions of electrochemical experiments do not apply. COMSOL modeling was used to compare and contrast differences in electrochemical behavior between conventional experimental setups and the in situ ec-S/TEM cells. Cell height strongly affected voltammogram measurements: peak magnitudes and shifts correlate directly to cell height. Reactant concentration above the electrode quickly decreases during deposition, leading to a planar diffusion-dominated regime. The concentration gradient prioritizes particle growth along the thin edges of the electrode and not on the planar part of the electrode. Experiments done in the ec-S/TEM ex situ of a TEM verify the model’s accuracy.