Baoyun Sun

Mr. Baoyun Sun


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
BSBaoyun Sun
Baoyun Sun
BMBinghe Ma
Binghe Ma
JLJian Luo
Jian Luo
BLBoyuan Li
Boyuan Li
CJChengyu Jiang
Chengyu Jiang
JDJinjun Deng
Jinjun Deng

1 February 2019 in Vacuum
Verified
Journal Article
Closed access
BSBaoyun Sun
Baoyun Sun
PWPengbin Wang
Pengbin Wang
BMBinghe Ma
Binghe Ma
JDJinjun Deng
Jinjun Deng
JLJian Luo
Jian Luo

15 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
BSBaoyun Sun
Baoyun Sun
PWPengbin Wang
Pengbin Wang
JLJian Luo
Jian Luo
JDJinjun Deng
Jinjun Deng
SGShiqi Guo
Shiqi Guo
BMBinghe Ma
Binghe Ma
A flexible hot-film sensor array for wall shear stress, flow separation, and transition measurement has been fabricated and implemented in experiments. Parylene C waterproof layer is vapor phase deposited to encapsulate the sensor. Experimental studies of shear stress and flow transition on a flat plate have been undertaken in a water tunnel with the sensor array. Compared with the shear stress derived from velocity profile and empirical formulas, the measuring errors of the hot-film sensors are less than 5%. In addition, boundary layer transition of the flat plate has also been detected successfully. Ensemble-averaged mean, normalized root mean square, and power spectra of the sensor output voltage indicate that the Reynolds number when transition begins at where the sensor array located is 1.82 × 105, 50% intermittency transition is 2.52 × 105, and transition finishes is 3.96 × 105. These results have a good agreement with the transition Reynolds numbers, as measured by the Laser Doppler Velocimetry (LDV) system.

4 February 2020 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
BSBaoyun Sun
Baoyun Sun
BMBing He Ma
Bing He Ma
PWPengbin Wang
Pengbin Wang
JLJian Luo
Jian Luo
JDJinjun Deng
Jinjun Deng
CGChao Gao
Chao Gao
The detailed flow characteristics in the boundary layer are critical for physical understanding of complex flow and aerodynamic performance optimization of aircraft. In this study, high sensitive micro-electro-mechanical system flexible hot-film sensor was developed for measurement of unsteady boundary layer flow. The effects of annealing temperature and time on the temperature coefficient of resistance (TCR) were studied, the highest TCR value of 5100 ppm °C −1 was obtained after 6 h of vacuum thermal annealing treatment at 400 °C. The flow transition and separation characteristics developed on two-dimensional NACA 0012 airfoil at various Reynolds numbers and angles of attack were investigated by using flexible hot-film sensors with validation by surface pressure distribution and aerodynamic force coefficient. The accurate locations of onset, 50% intermittent and end of transition were detected successfully. The behavior of spatial progression to the leading edge of transition point was found as the Reynolds number and angle of attack increases. The hot-film sensor measurements also demonstrated the static stall of the airfoil was caused by the leading edge separation bubble.

1 July 2019 in Progress in Organic Coatings
Verified
Journal Article
Closed access
XXXiaohan Xue
Xiaohan Xue
BSBaoyun Sun
Baoyun Sun
BWBo Wang
Bo Wang
BMBinghe Ma
Binghe Ma
CJChengyu Jiang
Chengyu Jiang

1 October 2017
Verified
Conference Paper
Closed access
BSBaoyun Sun
Baoyun Sun
BMBinghe Ma
Binghe Ma
YYYuchao Yan
Yuchao Yan
CJChengyu Jiang
Chengyu Jiang
WYWeizheng Yuan
Weizheng Yuan
YFYang Fang
Yang Fang
A MEMS flexible hot-film sensor array was developed for boundary layer shear stress distribution measurement and investigating flow separation and transition. An application of this sensor array to airfoil separation detection was demonstrated under static and dynamic conditions from 10° to 20° angle of attack (AOA) in wind tunnel with flow velocities 50m/s (Re≈1.33×10 6 ). Experimental data indicates that the flow separation and reattachment happened near 13.5° AOA under static condition. The separation occurred at approximately 15° AOA, and reattachment occurred at 12.5° AOA under dynamic condition, they both have a lag compare with the static result. These results have a good agreement with other previous researches.