Shiqi Guo

Dr. Shiqi Guo

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
BSBaoyun Sun
Baoyun Sun
PWPengbin Wang
Pengbin Wang
JLJian Luo
Jian Luo
JDJinjun Deng
Jinjun Deng
SGShiqi Guo
Shiqi Guo
BMBinghe Ma
Binghe Ma
A flexible hot-film sensor array for wall shear stress, flow separation, and transition measurement has been fabricated and implemented in experiments. Parylene C waterproof layer is vapor phase deposited to encapsulate the sensor. Experimental studies of shear stress and flow transition on a flat plate have been undertaken in a water tunnel with the sensor array. Compared with the shear stress derived from velocity profile and empirical formulas, the measuring errors of the hot-film sensors are less than 5%. In addition, boundary layer transition of the flat plate has also been detected successfully. Ensemble-averaged mean, normalized root mean square, and power spectra of the sensor output voltage indicate that the Reynolds number when transition begins at where the sensor array located is 1.82 × 105, 50% intermittency transition is 2.52 × 105, and transition finishes is 3.96 × 105. These results have a good agreement with the transition Reynolds numbers, as measured by the Laser Doppler Velocimetry (LDV) system.