A flexible hot-film sensor array for wall shear stress, flow separation, and transition measurement has been fabricated and implemented in experiments. Parylene C waterproof layer is vapor phase deposited to encapsulate the sensor. Experimental studies of shear stress and flow transition on a flat plate have been undertaken in a water tunnel with the sensor array. Compared with the shear stress derived from velocity profile and empirical formulas, the measuring errors of the hot-film sensors are less than 5%. In addition, boundary layer transition of the flat plate has also been detected successfully. Ensemble-averaged mean, normalized root mean square, and power spectra of the sensor output voltage indicate that the Reynolds number when transition begins at where the sensor array located is 1.82 × 105, 50% intermittency transition is 2.52 × 105, and transition finishes is 3.96 × 105. These results have a good agreement with the transition Reynolds numbers, as measured by the Laser Doppler Velocimetry (LDV) system.
Indium tin oxide (ITO) thin-film thermocouples monitor the temperature of hot section components in gas turbines. As an in situ measuring technology, the main challenge of a thin-film thermocouple is its installation on complex geometric surfaces. In this study, an ITO thin-film thermocouple probe based on a sapphire microrod was used to access narrow areas. The performance of the probe, i.e., the thermoelectricity and stability, was analyzed. This novel sensor resolves the installation difficulties of thin-film devices.
A micro-floating element wall shear stress sensor with backside connections has been developed for accurate measurements of wall shear stress under the turbulent boundary layer. The micro-sensor was designed and fabricated on a 10.16 cm SOI (Silicon on Insulator) wafer by MEMS (Micro-Electro-Mechanical System) processing technology. Then, it was calibrated by a wind tunnel setup over a range of 0 Pa to 65 Pa. The measurements of wall shear stress on a smooth plate were carried out in a 0.6 m × 0.6 m transonic wind tunnel. Flow speed ranges from 0.4 Ma to 0.8 Ma, with a corresponding Reynold number of 1.05 × 106~1.55 × 106 at the micro-sensor location. Wall shear stress measured by the micro-sensor has a range of about 34 Pa to 93 Pa, which is consistent with theoretical values. For comparisons, a Preston tube was also used to measure wall shear stress at the same time. The results show that wall shear stress obtained by three methods (the micro-sensor, a Preston tube, and theoretical results) are well agreed with each other.
High-precision piezoresistive pressure sensors play a significant role in aerospace, automotive, and other fields. Nonlinear error is the key factor that restricts the improvement of the sensor precision. A mathematical model for evaluating the sensor’s nonlinear error is established, based on which a piezoresistor sensitivity matching method is proposed to suppress the nonlinear error. By adjusting the piezoresistors' structure and position on the sensing membrane, four piezoresistors with equal sensitivity are obtained, and theoretical quasi-zero nonlinear error is achieved. To verify the design, sensor prototypes are fabricated utilizing the MEMS technology. After sensor packaging, a cylindrical absolute pressure sensor featuring a 4 mm diameter with a range from 0 to 100 kPa is acquired. The experimental results demonstrate the excellent performance of the proposed sensor, which indicates a nonlinear error as low as ±0.004%FS. Besides, the proposed sensor has a sensitivity of 1.6810 mV/kPa, a hysteresis of 0.025%, a repeatability of 0.015%, a zero drift of 0.03%FS, and a 3 dB frequency from 0 to 121.82 kHz. Moreover, the prototype is tested in the Mach 4 wind tunnel, and the measurement error between the proposed sensor and the true pressure is ±0.98%. This paper provides key sensing technology for high-precision surface pressure analysis of aircraft.
12 November 2014 in Journal of Biomedical Materials Research Part B: Applied Biomaterials