Chen Guan

Dr. Chen Guan

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
HYHuaxing Yu
Huaxing Yu
ZJZhongqing Jia
Zhongqing Jia
CGChen Guan
Chen Guan
ZYZhaohui Yu
Zhaohui Yu
XMXiaolong Ma
Xiaolong Ma
XWXiaofei Wang
Xiaofei Wang
With increasing quality demands in pharmaceutical and cosmetic packaging, this work presents a unified inspection platform for transparent ampoules that synergistically integrates stress measurement, dimensional measurement, and surface defect detection. Key innovations include an integrated system architecture, a shared-resource task scheduling mechanism, and an optimized deployment strategy tailored for production-like conditions. Non-contact residual stress measurement is achieved using the photoelastic method, while telecentric imaging combined with subpixel contour extraction enables accurate dimensional assessment. A YOLOv8-based deep learning model efficiently identifies multiple surface defect types, enhancing detection performance without increasing hardware complexity. Experimental validation under laboratory conditions simulating production lines demonstrates a stress measurement error of ±3 nm, dimensional accuracy of ±0.2 mm, and defect detection mAP@0.5 of 90.3%. The platform meets industrial inspection requirements and shows strong scalability and engineering potential. Future work will focus on real-time operation and exploring stress–defect coupling for intelligent quality prediction.

5 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ZJZhongqing Jia
Zhongqing Jia
ZYZhaohui Yu
Zhaohui Yu
CGChen Guan
Chen Guan
BZBing Zhao
Bing Zhao
XWXiaofei Wang
Xiaofei Wang
Automated visual inspection of safety-critical metal assemblies such as automotive door lock strikes remains challenging due to their complex three-dimensional geometry, highly reflective surfaces, and scarcity of defect samples. While 3D sensing technologies are often constrained by cost and speed, traditional 2D optical methods struggle with severe imaging artifacts and poor generalization under few-shot conditions. This work constructs a complete system integrating defect imaging, generation, and detection. It proposes an integrated framework through the co-design of an image acquisition system and deep generative models to holistically enhance defect perception capability. First, we develop an imaging system using dome illumination and a small-aperture lens to acquire high-quality images of non-planar metal surfaces. Subsequently, we introduce a dual-stage generation strategy: stage one employs an improved FastGAN with Dynamic Multi-Granularity Fusion Skip-Layer Excitation (DMGF-SLE) and perceptual loss to efficiently generate high-quality local defect patches; stage two utilizes Poisson image editing and an optimized loss function to seamlessly fuse defect patches into specified locations of normal images. This strategy avoids modeling the complete complex background, concentrating computational resources on creating realistic defects. Experiments on a dedicated dataset demonstrate that our method can efficiently generate realistic defect samples under few-shot conditions, achieving 11–24% improvement in Fréchet Inception Distance (FID) scores over baseline models. The generated synthetic data significantly enhances downstream detection performance, increasing YOLOv8’s mAP@50:95 from 50.4% to 60.5%. Beyond proposing individual technical improvements, this research provides a complete, synergistic, and deployable system solution—from physical imaging to algorithmic generation—delivering a computationally efficient and practically viable technical pathway for defect detection in highly reflective, non-planar metal components.

25 November 2025 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
QZQihao Zhang
Qihao Zhang
SQShuai Qu
Shuai Qu
XGXibao Gao
Xibao Gao
SBShuo Bai
Shuo Bai
CGChen Guan
Chen Guan
JNJiasheng Ni
Jiasheng Ni
In this study, we present and experimentally verify a method based on the adaptive matrix block weighting (AMBW) algorithm to achieve large-strain measurement in long-distance, high-spatial-resolution optical frequency domain reflectometry (OFDR) systems. The system generates two-dimensional (2D) cross-correlation images representing strain information by calculating cross-correlations between the reference signals (RS) and measurement signals (MS) for each segment of the sensing fiber, thereby determining the strain distribution along the fiber. In practical applications, however, strain-induced stretching causes spatial misalignment between the measurement and reference signals. Consequently, the cross-correlation images become contaminated with bad points and outliers, leading to a significant reduction in measurement accuracy. To mitigate the above effects and enhance measurement accuracy, we employ the AMBW method to process the 2D cross-correlation images. Unlike conventional image denoising techniques such as Wiener filtering (WF), Gaussian filtering (GF), and median filtering (MF), the AMBW algorithm leverages both the redundancy and inherent correlation within the 2D cross-correlation data by adaptively adjusting the size of the matrix blocks used in similarity weighting based on the spatial distribution of local outliers. This adaptive capability allows it to effectively eliminate bad points and outlier. Experimental results show that the proposed method accurately measures strain gradients from 500 μϵ to 5500 μϵ with a spatial resolution of 2 mm, operating at a wavelength scanning rate of 10 nm/s over a 56 m sensing fiber. The proposed approach offers an effective solution for long-distance, high-spatial-resolution, large-strain measurement in OFDR systems, underscoring its strong potential and practical value.

21 November 2025 in Infrared Physics & Technology
Verified
Journal Article
Closed access
SBShuo Bai
Shuo Bai
CGChen Guan
Chen Guan
QZQihao Zhang
Qihao Zhang
XGXibao Gao
Xibao Gao
SQShuai Qu
Shuai Qu

25 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
XMXiaolong Ma
Xiaolong Ma
XWXiaofei Wang
Xiaofei Wang
RZRuizhan Zhai
Ruizhan Zhai
ZJZhongqing Jia
Zhongqing Jia
WZWei Zhang
Wei Zhang
CGChen Guan
Chen Guan
Phase-shifting fringe projection (PSFP) is widely used in industrial inspection and three-dimensional measurement, where γ nonlinearity of the projector–camera system is traditionally treated as a phase-error source to be calibrated or compensated. In this work, γ nonlinearity is reinterpreted from an imaging perspective and shown to act as a statistical distortion mechanism that reshapes modulation stability, overexposure behavior, and defect saliency in fringe-based imaging. Building on the intrinsic DC–AC decomposition of phase-shifting demodulation, we analyze how γ nonlinearity interacts with fringe modulation and frequency-selective transfer. An analytical model reveals that γ nonlinearity simultaneously suppresses the fringe fundamental and introduces harmonic leakage, leading to systematic compression of mean modulation contrast in high-brightness regions. As a result, γ correction does not necessarily enhance mean-based defect contrast and may even reduce it, contrary to common intuition. We further demonstrate that the primary benefit of γ correction lies in statistical stabilization rather than contrast amplification. By introducing modulation-domain saliency formulations and a frequency-domain harmonic energy ratio, a physical link is established between γ nonlinearity, overexposure, and defect separability. Controlled experiments on highly reflective sheet-metal specimens confirm that while mean-contrast- and SNR-based saliency metrics often decrease after γ correction, separability-based metrics consistently improve due to reduced nonlinear- and saturation-induced variance. Cross-channel and cross-condition analyses further show that modulation and reflectance images respond differently to γ correction, yet metric-level separability exhibits consistent improvement across channels. These results clarify the true role of γ correction in fringe-based inspection and provide theoretical insight and practical guidance for robust defect imaging under nonlinear and near-overexposure conditions.