Phase compensated proportional resonant (PR) controllers with phase leading angles embedded into resonant controllers, are used to improve the system stability, when the grid-connected inverter is connected to a weak grid with large grid impedance. However, an inappropriate phase leading angle will cause obvious anti-peak in the magnitude response of phase compensated PR controller. Thus, the phase leading angle should be selected carefully. The conventional phase compensation (CPC) method for selecting the phase leading angle can maximize the system phase margin, but at the expense of large peaks in the magnitude response of sensitivity transfer function. Meanwhile, the bandwidths of resonant controllers will be reduced. In the paper, an improved phase compensation (IPC) method is proposed, which does not cause peaks in the magnitude response of sensitivity transfer function while providing sufficient phase margin. Experimental tests were carried out on a single phase grid-connected inverter. The effectiveness of the proposed method is proved in terms of the steady-state and transient performances, as well as the performance under the grid frequency deviation.
8 September 2023 in IEEE Transactions on Industry Applications
Most current proton exchange membrane fuel cell (PEMFC) fault diagnosis models are not updated after offline training is completed, so they cannot learn new data features. For this problem, a PEMFC fault diagnosis model based on an equivalent circuit and an online sequential extreme learning machine (OS-ELM) framework is proposed. Under different operating conditions, the range of equivalent circuit element values is different, which is conducive to fault diagnosis. Element values constitute a dataset, from which OS-ELM is used to learn data features, and PEMFC fault diagnosis and isolation can be accomplished. OS-ELM has online learning capability. During the operation of PEMFC, equivalent circuit fitting is performed on multiple sets of sample data obtained using electrical impedance spectroscopy (EIS). Optimized fuzzy C-means (FCM) is used to cluster and partition sample data for online updating of OS-ELM models. The experimental results show that the proposed PEMFC fault diagnosis model not only has the speed and accuracy of fault diagnosis but also has the ability to learn fault characteristics online.
The stability and control performances of grid‐connected inverters can be significantly influenced due to the uncertain grid impedance and large grid voltage background harmonics. The system stability and resonance of the grid‐connected inverter were investigated separately. Thus, their relationship needs to be identified further. In this study, the equivalent impedance model and the current control model of the grid‐connected inverter are established. Based on the three resonance cases: positive incomplete resonance, complete resonance, and negative incomplete resonance, the relationship between the system stability and resonance is identified. Moreover, the principle of harmonic amplification of the grid injected current is analysed thoroughly. It is revealed that the harmonic amplification is always accompanied by low stability of the system, and the centre frequency of harmonic distribution is where the system has the lowest stability. In order to alleviate the harmonics of the grid injected current, it is inevitable to ensure that the system maintains a sufficient phase margin to thwart the grid voltage background harmonics and the inverter output voltage harmonics. Finally, the simulation has been accomplished in MATLAB/SIMULINK software, and the hardware platforms are built with a single phase grid‐connected inverter in order to verify the proposed comprehensive analysis further.
It is a challenging task to design controller for the digitally controlled LCL‐filtered grid‐connected inverter to achieve high‐quality grid current, avoid undesired resonance, and offer robust performance against system parameters uncertainties. To address the problem, in this study, the linear quadratic regulator (LQR) for a digitally controlled grid‐connected inverter is proposed. Discrete‐time state‐space model of the inverter is established by discretising the system continuous state‐space equations and taking into account one sampling period delay. Then, a systematic design procedure for selecting the state weighting matrix Q is presented, so that the poles of the closed‐loop system are assigned and the desired performances can be achieved. Moreover, to further attenuate the grid voltage background harmonics, the selective harmonic controllers are designed based on the LQR. Compared with the conventional dual current loop control strategy, the proposed LQR controller can achieve low harmonic distortion, fast dynamic response, and good robustness against system parameters deviations. Finally, time‐domain simulations are carried out in MATLAB/SIMULINK software and experimental tests are performed on the experimental setup. The results have demonstrated the effectiveness of the proposed LQR method.