Karolina Dziąbowska

Ms. Karolina Dziąbowska

SensDx S.A.
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
KDKarolina Dziąbowska
Karolina Dziąbowska
ECElżbieta Czaczyk
Elżbieta Czaczyk
DNDawid Nidzworski
Dawid Nidzworski
The basic affairs connected to the influenza virus were reviewed in the article, highlighting the newest trends in its diagnostic methods. Awareness of the threat of influenza arises from its ability to spread and cause a pandemic. The undiagnosed and untreated viral infection can have a fatal effect on humans. Thus, the early detection seems pivotal for an accurate treatment, when vaccines and other contemporary prevention methods are not faultless. Public health is being attacked with influenza containing new genes from a genetic assortment between animals and humankind. Unfortunately, the population does not have immunity for mutant genes and is attacked in every viral outbreak season. For these reasons, fast and accurate devices are in high demand. As currently used methods like Rapid Influenza Diagnostic Tests lack specificity, time and cost-savings, new methods are being developed. In the article, various novel detection methods, such as electrical and optical were compared. Different viral elements used as detection targets and analysis parameters, such as sensitivity and specificity, were presented and discussed.

1 February 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
KSK. Siuzdak
K. Siuzdak
PNPawel Niedzialkowski
Pawel Niedzialkowski
MSMichał Sobaszek
Michał Sobaszek
TŁT. Łęga
T. Łęga
MSMiroslaw Sawczak
Miroslaw Sawczak
RBRobert Bogdanowicz
Robert Bogdanowicz

9 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZCZofia Cebula
Zofia Cebula
SNSabina Nidzworska
Sabina Nidzworska
KDKarolina Dziąbowska
Karolina Dziąbowska
MSMarta Skwarecka
Marta Skwarecka
Natalia MalinowskaNatalia Malinowska
Natalia Malinowska
DNDawid Nidzworski
Dawid Nidzworski
The present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA). Sensor development was characterized by cyclic voltammetry (CV) and antigen detection by electrochemical impedance spectroscopy (EIS) measurements. Seven analyzed strains of Psl were verified as positive by the reference method (PCR) and this immunoassay, proving sensor specificity. Label-free electrochemical detection was in the linear range 1 × 103–1.2 × 105 CFU/mL (colony-forming unit) with an R2 coefficient of 0.992 and a detection limit (LOD) of 337 CFU/mL. The sensor did not interfere with negative probes like buffers and other bacteria. The assay was proven to be fast (10 min detection) and easy in preparation. The advantage was the simplicity and availability of the verified analyte (whole bacteria) as the method does not require sample pretreatment (e.g., DNA isolation). EIS biosensing technique was chosen as one of the simplest and most sensitive with the least destructive influence on the probes compared to other electrochemical methods.

13 November 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
WBWioleta Białobrzeska
Wioleta Białobrzeska
DFDaniel Firganek
Daniel Firganek
MCMaciej Czerkies
Maciej Czerkies
TLTomasz Lipniacki
Tomasz Lipniacki
MSMarta Skwarecka
Marta Skwarecka
DNDawid Nidzworski
Dawid Nidzworski
This paper presents the development and comparison of label-free electrochemical immunosensors based on screen-printed gold and glassy carbon (GC) disc electrodes for efficient and rapid detection of respiratory syncytial virus (RSV). Briefly, the antibody specific to the F protein of RSV was successfully immobilized on modified electrodes. Antibody coupling on the Au surface was conducted via 4-aminothiophenol (4-ATP) and glutaraldehyde (GA). The GC surface was modified with poly-L-lysine (PLL) for direct anti-RSV conjugation after EDC/NHS (1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide/N-Hydroxysuccinimide) activation. Electrochemical characterizations of the immunosensors were carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). GC-based immunosensors show a dynamic range of antigen detection from 1.0 × 105 PFU/mL to 1.5×107 PFU/mL, more than 1.0 × 105 PFU/mL to 1.0 × 107 PFU/mL for the Au-based sensor. However, the GC platform is less sensitive and shows a higher detection limit (LOD) for RSV. The limit of detection of the Au immunosensor is 1.1 × 103 PFU/mL, three orders of magnitude lower than 2.85 × 106 PFU/mL for GC. Thus, the Au-based immunosensor has better analytical performance for virus detection than a carbon-based platform due to high sensitivity and very low RSV detection, obtained with good reproducibility.

17 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Natalia MalinowskaNatalia Malinowska
Natalia Malinowska
WBWioleta Białobrzeska
Wioleta Białobrzeska
TŁTomasz Łęga
Tomasz Łęga
KPKatarzyna Pałka
Katarzyna Pałka
KDKarolina Dziąbowska
Karolina Dziąbowska
DNDawid Nidzworski
Dawid Nidzworski
Streptococcus pyogenes is a known cause of a wide spectrum of diseases, from mild and acute to severe invasive infections. This paper concerns the development of a novel impedimetric biosensor for the detection of the mentioned human pathogen. The proposed biosensor is a gold disk electrode modified with commercially available antibodies attached to the surface of the electrode by carbodiimide chemistry. The conducted tests confirmed the specificity of the antibodies used, which was also demonstrated by the results obtained during the detection of S. pyogenes using electrochemical impedance spectroscopy. The developed sensor successfully detected the presence of S. pyogenes in the sample and the detection limit was calculated as 9.3 cfu/mL. The results obtained show a wide linear range for verified concentrations of this pathogen in a sample from 4.2 × 102 to 4.2 × 106 cfu/mL. Furthermore, the optimal experimentally determined time required to perform pathogen detection in the sample was estimated as 3 min, and the test did not lead to the degradation of the sample.

21 March 2018
Verified
Book Chapter
Open access
PDF file
KDKarolina Dziąbowska
Karolina Dziąbowska
ECElżbieta Czaczyk
Elżbieta Czaczyk
DNDawid Nidzworski
Dawid Nidzworski
Introducing biochemical factor to electronic devices have created a new branch of science. Recent development in biosensing technology enabled progress in pathogens detection. Currently, wide range of biomarkers (enzymes, peptides, DNA, microorganisms, etc. )recognize various target analytes, starting from basic metabolism changes to serious infections caused by pathogens. Improved sensitivity, selectivity and response time of sensors have instantly replaced traditional techniques. Easy handling, low production costs and miniaturization have met therapeutics need. Biosensing technologies are very strong point in telemedicine in public healthcare. This chapter will focus on electrochemical techniques for pathogens detection and show trending applications in biosensing technologies.