Wioleta Białobrzeska

Dr. Wioleta Białobrzeska

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
WBWioleta Białobrzeska
Wioleta Białobrzeska
DFDaniel Firganek
Daniel Firganek
MCMaciej Czerkies
Maciej Czerkies
TLTomasz Lipniacki
Tomasz Lipniacki
MSMarta Skwarecka
Marta Skwarecka
DNDawid Nidzworski
Dawid Nidzworski
This paper presents the development and comparison of label-free electrochemical immunosensors based on screen-printed gold and glassy carbon (GC) disc electrodes for efficient and rapid detection of respiratory syncytial virus (RSV). Briefly, the antibody specific to the F protein of RSV was successfully immobilized on modified electrodes. Antibody coupling on the Au surface was conducted via 4-aminothiophenol (4-ATP) and glutaraldehyde (GA). The GC surface was modified with poly-L-lysine (PLL) for direct anti-RSV conjugation after EDC/NHS (1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide/N-Hydroxysuccinimide) activation. Electrochemical characterizations of the immunosensors were carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). GC-based immunosensors show a dynamic range of antigen detection from 1.0 × 105 PFU/mL to 1.5×107 PFU/mL, more than 1.0 × 105 PFU/mL to 1.0 × 107 PFU/mL for the Au-based sensor. However, the GC platform is less sensitive and shows a higher detection limit (LOD) for RSV. The limit of detection of the Au immunosensor is 1.1 × 103 PFU/mL, three orders of magnitude lower than 2.85 × 106 PFU/mL for GC. Thus, the Au-based immunosensor has better analytical performance for virus detection than a carbon-based platform due to high sensitivity and very low RSV detection, obtained with good reproducibility.

17 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Natalia MalinowskaNatalia Malinowska
Natalia Malinowska
WBWioleta Białobrzeska
Wioleta Białobrzeska
TŁTomasz Łęga
Tomasz Łęga
KPKatarzyna Pałka
Katarzyna Pałka
KDKarolina Dziąbowska
Karolina Dziąbowska
DNDawid Nidzworski
Dawid Nidzworski
Streptococcus pyogenes is a known cause of a wide spectrum of diseases, from mild and acute to severe invasive infections. This paper concerns the development of a novel impedimetric biosensor for the detection of the mentioned human pathogen. The proposed biosensor is a gold disk electrode modified with commercially available antibodies attached to the surface of the electrode by carbodiimide chemistry. The conducted tests confirmed the specificity of the antibodies used, which was also demonstrated by the results obtained during the detection of S. pyogenes using electrochemical impedance spectroscopy. The developed sensor successfully detected the presence of S. pyogenes in the sample and the detection limit was calculated as 9.3 cfu/mL. The results obtained show a wide linear range for verified concentrations of this pathogen in a sample from 4.2 × 102 to 4.2 × 106 cfu/mL. Furthermore, the optimal experimentally determined time required to perform pathogen detection in the sample was estimated as 3 min, and the test did not lead to the degradation of the sample.

7 June 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
WBWioleta Białobrzeska
Wioleta Białobrzeska
KDKarolina Dziąbowska
Karolina Dziąbowska
MLMałgorzata Lisowska
Małgorzata Lisowska
M. Aiman MohtarM. Aiman Mohtar
M. Aiman Mohtar
PMPetr Muller
Petr Muller
DNDawid Nidzworski
Dawid Nidzworski
The detection of cancer antigens is a major aim of cancer research in order to develop better patient management through early disease detection. Many cancers including prostate, lung, and ovarian secrete a protein disulfide isomerase protein named AGR2 that has been previously detected in urine and plasma using mass spectrometry. Here we determine whether a previously developed monoclonal antibody targeting AGR2 can be adapted from an indirect two-site ELISA format into a direct detector using solid-phase printed gold electrodes. The screen-printed gold electrode was surface functionalized with the anti-AGR2 specific monoclonal antibody. The interaction of the recombinant AGR2 protein and the anti-AGR2 monoclonal antibody functionalized electrode changed its electrochemical impedance spectra. Nyquist diagrams were obtained after incubation in an increasing concentration of purified AGR2 protein with a range of concentrations from 0.01 fg/mL to 10 fg/mL. In addition, detection of the AGR2 antigen can be achieved from cell lysates in medium or artificial buffer. These data highlight the utility of an AGR2-specific monoclonal antibody that can be functionalized onto a gold printed electrode for a one-step capture and quantitation of the target antigen. These platforms have the potential for supporting methodologies using more complex bodily fluids including plasma and urine for improved cancer diagnostics.

19 March 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
WBWioleta Białobrzeska
Wioleta Białobrzeska
MSMarta Sosnowska
Marta Sosnowska
TŁTomasz Łęga
Tomasz Łęga
KSKasjan Szemiako
Kasjan Szemiako
SNSabina Nidzworska
Sabina Nidzworska
Beata GromadzkaBeata Gromadzka
Beata Gromadzka
The global market increasingly demands alternative rapid diagnostic tools, such as disposable biosensors, to meet the growing need for point-of-care clinical testing of infectious diseases. Bacterial vaginosis (BV), a common infection caused by Gardnerella vaginalis, requires efficient and accurate detection methods to improve patient outcomes and prevent complications. However, existing diagnostic approaches often lack sensitivity, specificity, or rapid response times, highlighting the need for innovative biosensing solutions. In response to this challenge, we developed a peptide-based electrochemical biosensor for the specific detection of Gardnerella vaginalis. The sensor was designed to achieve high sensitivity, selectivity, and stability, with detection performed through electrochemical techniques. Cyclic voltammetry (CV) was employed to monitor electron transfer kinetics at the electrode surface, while electrochemical impedance spectroscopy (EIS) provided insights into changes in resistance and capacitance during peptide binding. The sensor fabrication involved covalently bonding anti-Gardnerella vaginalis peptides to a gold nanoparticle (AuNP)-modified graphene electrode, significantly enhancing bioreceptor immobilization stability and increasing the surface area for target binding interactions. The incorporation of AuNPs improved signal amplification due to their high surface-to-volume ratio and excellent conductivity, leading to enhanced sensor performance. The biosensor demonstrated a low detection limit (LOD) of 0.02305 μg/mL, with a rapid response time of 5 min across various concentrations of the target Gardnerella vaginalis antigen. The results confirmed specific and selective binding to the pathogen marker, with minimal interference from non-target species, ensuring high accuracy. The combination of graphene, AuNPs, and peptide bioreceptors resulted in robust signal enhancement, making this biosensor a promising tool for fast and reliable point-of-care diagnostics in clinical settings.

16 September 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
MBMateusz Brodowski
Mateusz Brodowski
MKMarcin Kowalski
Marcin Kowalski
WBWioleta Białobrzeska
Wioleta Białobrzeska
KPKatarzyna Pałka
Katarzyna Pałka
RWRafał Walkusz
Rafał Walkusz
DNDawid Nidzworski
Dawid Nidzworski
The study reports a methodology of selecting the optimal receptor to create an electrochemical immunosensor for equine arteritis virus (EAV) protein detection. The detection was based on antigen recognition by antibodies immobilized on gold electrodes. Modification steps were controlled by electrochemical impedance spectroscopy and cyclic voltammetry measurements. In order to obtain the impedance immunosensor with the best parameters, seven different receptors complementary to equine arteritis virus protein were used. In order to make the selection, a rapid screening test was carried out to check the sensor’s response to blank, extremely low and high concentrations of target EAV protein, and negative sample: M protein from Streptococcus equi and glycoprotein G from Equid alphaherpesvirus 1. F6 10G receptor showed the best performance.

19 May 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
DBDaniel Bigus
Daniel Bigus
WBWioleta Białobrzeska
Wioleta Białobrzeska
EBEwelina Bięga
Ewelina Bięga
AGAnna Grela
Anna Grela
ASAleksandra Siedlar
Aleksandra Siedlar
DNDawid Nidzworski
Dawid Nidzworski
This publication presents the results of work on the development of a quick and cheap electrochemical immunosensor for the diagnosis of infections with the pathogen Streptococcus agalactiae. The research was carried out on the basis of the modification of the well-known glassy carbon (GC) electrodes. The surface of the GC (glassy carbon) electrode was covered with a film made of nanodiamonds, which increased the number of sites for the attachment of anti-Streptococcus agalactiae antibodies. The GC surface was activated with EDC/NHS (1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide/N-Hydroxysuccinimide). Determination of electrode characteristics after each modification step, performed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS).