Background/Objectives: The conventional practice in clinical settings involves using multi-use surgical instrumentation (SI). However, there is a growing trend towards transforming these multi-use SIs into disposable surgical instruments, driven by economic and environmental considerations without considering the biomechanical aspects. This study focuses on redesigning an SI kit for implanting cervical spinal facet cages. Understanding the boundary conditions (forces, torques, and bending moments) acting on the SI during surgery is crucial for optimizing its design and materials. Therefore, this study aims to develop a measurement system (MS) to record these loads during implantation and validate it through in vitro testing. Methods: A combined numerical–experimental approach was used to design and calibrate the MS. Finite element analysis (FE) was used to optimize the geometry of the sensitive element of the MS. This was followed by the manufacturing phase using 3D printing and then by calibration tests to determine the stiffness of the system. Finally, the MS was used to measure the boundary conditions applied during SI use during in vitro tests on a cervical Sawbone spine. Results: After designing the measurement system (MS) via finite element analysis, calibration tests determined stiffness values of KF = 1.2385 N/(µm/m) (axial compression), KT = −0.0015 Nm/(µm/m) (torque), and KB = 0.0242 Nm/(µm/m) (non-axial force). In vitro tests identified maximum loads of 40.84 N (compression) and 0.11 Nm (torque). Conclusions: This study developed a measurement system to assess surgical implant boundary conditions. The data will support finite element modeling, guiding the optimization of implant design and materials.
19 February 2025 in International Journal for Numerical Methods in Biomedical Engineering
The bi‐modular hip prosthesis is characterized by two tapered connections: a circular cross‐section at the head–neck interface and a rectangular cross‐section at the neck‐stem interface. Even if the latter guarantees customization, it concerns a high rate of early failure. The connection resistance is relatable to machining (tolerances cause angular mismatch), implantation (hammering force or manual), and usage (Body Mass Index [BMI]). Due to the lack of literature about the neck‐stem coupling, this work aims to investigate how the geometry of the rectangular taper connection and the external loads affect the fatigue strength of a bi‐modular hip prosthesis through a 3D Finite Element Model (FEM). Nine combinations of neck‐stem coupling are obtained considering the tolerances' limits on frontal and lateral angles as . The CoCr neck and the Ti6Al4V stem, studied in their halved, are constrained and loaded inspired by the standard ISO 7206: the stem is distally encastered simulating the embedding and tilted by 10° concerning the sagittal plane, while the force is applied vertically. First, the influence of the assembly is investigated using , , and ; then, a cyclical vertical force varying from to is imposed. Finally, one combination is analyzed in its integrity to evaluate the effect of the out‐of‐plane load. The study's findings concern: (i) a positive angular mismatch, which is responsible for proximal contacts, improves fatigue life, reducing Sines stress up to 33%; (ii) the higher the assembly force the higher the neck stability and the lower the extension of the overstressed lateral area; (iii) the implant fatigue resistance is directly proportional to the patient's BMI; and (iv) the out‐of‐plane external load causes a 40% increment in the fatigue failure risk.
Selecting an optimal bone graft for critical-sized defects in load-bearing regions such as the spine, long bones, and jawbone is essential to ensure structural integrity and promote bone regeneration. While fixation systems provide initial stability, the graft’s intrinsic mechanical properties determine its ability to withstand physiological loads. This study aims to experimentally characterize an innovative biomorphic bioceramic to calibrate a constitutive material model and evaluate its performance in in silico post-surgical scenarios. The ceramic scaffold underwent both static (axial and transverse compression and axial torsion) and fatigue (axial compression) mechanical testing to determine its key mechanical properties. These data were used to calibrate a material model, which was then implemented in finite element simulations of an interbody fusion procedure at the L4–L5 level to assess its mechanical performance under post-surgical loading conditions. The experimental tests highlighted an anisotropic material behavior, with the Young’s modulus in the direction of the main macroscopic porosity three-times higher the value measured in the transverse direction (4.65 vs. 1.60 GPa). The calibrated numerical model accurately reproduced the experimental results, showing negligible deviations (< 4%). Preliminary simulations indicated that the scaffold could adequately sustain post-fusion physiological loads, but further implant optimization is required to properly ensure mechanical stability. This study provided an in-depth mechanical characterization of a novel bioceramic, identifying its key mechanical properties. By integrating experimental and numerical approaches, the mechanical resistance of a bioceramic implant for lumbar interbody fusion was preliminarily assessed, paving the way for further developments in this field.