Fernando De Souza Campos

Fernando De Souza Campos

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2016 in Sensors
Verified
Journal Article
Open access
PDF file
BCBruno Albuquerque de Castro
Bruno Albuquerque de Castro
GCGuilherme Clerice
Guilherme Clerice
CRCaio Ramos
Caio Ramos
AAAndre Luiz Andreoli
Andre Luiz Andreoli
Fabricio BaptistaFabricio Baptista
Fabricio Baptista
JUJosé Alfredo Covolan Ulson
José Alfredo Covolan Ulson
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Although commercial acoustic emission sensors have been used to monitor partial discharges in power transformers, they still represent a significant cost. In order to overcome this drawback, this paper presents a study of the feasibility of low-cost piezoelectric sensors to identify partial discharges in mineral insulating oil of power transformers. The analysis of the feasibility of the proposed low-cost sensor is performed by its comparison with a commercial acoustic emission sensor commonly used to detect partial discharges. The comparison between the responses in the time and frequency domain of both sensors was carried out and the experimental results indicate that the proposed piezoelectric sensors have great potential in the detection of acoustic waves generated by partial discharges in insulation oil, contributing for the popularization of this noninvasive technique.

9 May 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PSPavlos Silvestros
Pavlos Silvestros
EPEzio Preatoni
Ezio Preatoni
HGHarinderjit S. Gill
Harinderjit S. Gill
SGSabina Gheduzzi
Sabina Gheduzzi
Bruno Agostinho HernandezBruno Agostinho Hernandez
Bruno Agostinho Hernandez
Dario CazzolaDario Cazzola
Dario Cazzola
Head collisions in sport can result in catastrophic injuries to the cervical spine. Musculoskeletal modelling can help analyse the relationship between motion, external forces and internal loads that lead to injury. However, impact specific musculoskeletal models are lacking as current viscoelastic values used to describe cervical spine joint dynamics have been obtained from unrepresentative quasi-static or static experiments. The aim of this study was to develop and validate a cervical spine musculoskeletal model for use in axial impacts. Cervical spine specimens (C2-C6) were tested under measured sub-catastrophic loads and the resulting 3D motion of the vertebrae was measured. Specimen specific musculoskeletal models were then created and used to estimate the axial and shear viscoelastic (stiffness and damping) properties of the joints through an optimisation algorithm that minimised tracking errors between measured and simulated kinematics. A five-fold cross validation and a Monte Carlo sensitivity analysis were conducted to assess the performance of the newly estimated parameters. The impact-specific parameters were integrated in a population specific musculoskeletal model and used to assess cervical spine loads measured from Rugby union impacts compared to available models. Results of the optimisation showed a larger increase of axial joint stiffness compared to axial damping and shear viscoelastic parameters for all models. The sensitivity analysis revealed that lower values of axial stiffness and shear damping reduced the models performance considerably compared to other degrees of freedom. The impact-specific parameters integrated in the population specific model estimated more appropriate joint displacements for axial head impacts compared to available models and are therefore more suited for injury mechanism analysis.

27 November 2007 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
NFNaser Faramarzpour
Naser Faramarzpour
Jamal DeenJamal Deen
Jamal Deen
SSShahram Shirani
Shahram Shirani
Qiyin FangQiyin Fang
Qiyin Fang
LLLouis W. C. Liu
Louis W. C. Liu
JSJacobus W. Swart
Jacobus W. Swart
An analysis of the active pixel sensor (APS), considering the doping profiles of the photodiode in an APS fabricated in a 0.18 mum standard CMOS technology, is presented. A simple and accurate model for the junction capacitance of the photodiode is proposed. An analytic expression for the output voltage of the APS obtained with this capacitance model is in good agreement with measurements and is more accurate than the models used previously. A different mode of operation for the APS based on the dc level of the output is suggested. This new mode has better low-light-level sensitivity than the conventional APS operating mode, and it has a slower temporal response to the change of the incident light power. At 1 muW/cm2 and lower levels of light, the measured signal-to-noise ratio (SNR) of this new mode is more than 10 dB higher than the SNR of previously reported APS circuits. Also, with an output SNR of about 10 dB, the proposed dc level is capable of detecting light powers as low as 20 nW/cm2, which is about 30 times lower than the light power detected in recent reports by other groups.

1 April 2020 in Orthopaedic Journal of Sports Medicine
Verified
Journal Article
Open access
PDF file
JRJames R. Robinson
James R. Robinson
Bruno Agostinho HernandezBruno Agostinho Hernandez
Bruno Agostinho Hernandez
CTClare Taylor
Clare Taylor
Richie Harinderjit Singh GillRichie Harinderjit Singh Gill
Richie Harinderjit Singh Gill
Background: A 2 mm–wide ultrahigh-molecular-weight polyethylene (UHMWPE) tape improves the contact pressure at root repair sites compared with high-strength suture and provides a stronger repair construct. UHMWPE tape is commonly used in rotator cuff repair, and fixation is often achieved with knotless suture anchors. The optimal method for tape fixation for meniscal root repair has not been established. Hypothesis: The use of suture anchors for the tibial fixation of 2-mm UHMWPE tape transosseous root repairs will lead to better biomechanical performance compared with other fixation methods. Methods: The medial meniscal posterior root attachment in 25 porcine knees was divided, and a standardized transtibial root repair was performed using 2-mm UHMWPE tape. The testing was performed by cyclic loading followed by load to failure. Tibial fixation was randomized to 5 tibial fixation types: (1) cortical fixation button, (2) pound-in suture anchor with screw-down interference suture locking, (3) tap-in suture anchor with inner locking plug, (4) postscrew, and (5) postscrew and washer. Results: There was no difference in displacement during cyclic loading between tibial fixation groups except for a highly significant difference in the maximum load at failure. Repairs in both suture anchor fixation groups all failed by tape slippage at relatively low loads (median, 145 and 116 N, respectively). Repairs tied over a cortical button, postscrew, or screw and washer failed by tape breakage at loads of 431, 405, and 528 N. Conclusion: For meniscal root repairs with 2-mm UHMWPE tape, use of suture anchors offers weaker fixation compared with tying over a button or postscrew/washer. While suture anchor fixation may be adequate for nonweightbearing postoperative protocols, it may not allow for more accelerated weightbearing.

1 June 2019 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
FCFernando De Souza Campos
Fernando De Souza Campos
BCBruno Albuquerque de Castro
Bruno Albuquerque de Castro
DBDanilo Ecidir Budoya
Danilo Ecidir Budoya
Fabricio BaptistaFabricio Baptista
Fabricio Baptista
JUJosé Alfredo Covolan Ulson
José Alfredo Covolan Ulson
AAAndre Luiz Andreoli
Andre Luiz Andreoli
Structural health monitoring (SHM) based on the electromechanical impedance (EMI) has been pointed out as a promising method for detecting structural damage. However, practical problems such as the effects of temperature variation on the electrical impedance signatures of piezoelectric transducers have made it difficult to effectively apply this method of detecting damage in real structures. Therefore, in order to contribute to the effective application of the EMI method in real structures, this study presents a new feature extraction approach insensitive to temperature variations. The proposed method is based on the Akaike statistical criterion algorithm, which extracts the number of significant resonance peaks from the electrical impedance signatures. Tests were performed on an aluminium bar with different damage sizes and under different temperatures. The experimental results indicate that the proposed method is capable of detecting and quantifying structural damage in environments under temperature variation.

20 December 2012 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FCFernando De Souza Campos
Fernando De Souza Campos
NFNaser Faramarzpour
Naser Faramarzpour
OMOgnian Marinov
Ognian Marinov
Jamal DeenJamal Deen
Jamal Deen
JSJacobus Willibordus Swart
Jacobus Willibordus Swart
The silicon-based gate-controlled lateral bipolar junction transistor (BJT) is a controllable four-terminal photodetector with very high responsivity at low-light intensities. It is a hybrid device composed of a MOSFET, a lateral BJT, and a vertical BJT. Using sufficient gate bias to operate the MOS transistor in inversion mode, the photodetector allows for increasing the photocurrent gain by 106 at low light intensities when the base-emitter voltage is smaller than 0.4 V, and BJT is off. Two operation modes, with constant voltage bias between gate and emitter/source terminals and between gate and base/body terminals, allow for tuning the photoresponse from sublinear to slightly above linear, satisfying the application requirements for wide dynamic range, high-contrast, or linear imaging. MOSFETs from a standard 0.18-μm triple-well complementary-metal oxide semiconductor technology with a width to length ratio of 8 μm /2 μm and a total area of ~ 500 μm2 are used. When using this area, the responsivities are 16-20 kA/W.