Giuseppe Pizzi

Dr. Giuseppe Pizzi


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SUSara Ungania
Sara Ungania
MDMarco D’Arienzo
Marco D’Arienzo
EMEmilio Mezzenga
Emilio Mezzenga
GPGiuseppe Pizzi
Giuseppe Pizzi
GVGiulio Eugenio Vallati
Giulio Eugenio Vallati
LSLidia Strigari
Lidia Strigari
At a time of increasing evidence for dose-effect relationships in radioembolization (RE) with 90Y-microspheres, the general consensus is that there is an urgent need for accurate treatment planning and dose assessment in patients undergoing RE treatment. This work aimed at assessing the usefulness of 99mTc macroaggregated albumin (MAA) SPECT/CT imaging for personalized provisional RE dosimetry considering a 3D-printed patientlike phantom (AdboMan phantom). A homemade tool was developed in MATLAB for image analysis and absorbed dose calculation. Two dose calculaton methods were implemented and used to calculate dose volume histograms: (I) dose kernel method and (II) local energy deposition method. The accuracy of the two different dosimetric methods was evaluated by means of 3D γ-index (1%–1 mm and 2%–2 mm) implemented in the tool. Differences between the two dose calculation methods using the 3D γ-index are within 1%–1 mm and 2%–2 mm for all AbdoMan inserts, with a passing rate of 99.9% and 100%, respectively, proving a good agreement between the two calculation methods. The present study supports the use of 99mTc-MAA SPECT acquisition for provisional dosimetry along with the local energy deposition method to convert reconstructed SPECT data into absorbed dose maps. As long as 99mTc-MAA SPECT acquisitions are performed on liver lesions larger than 40 mm, the absorbed dose computed by means of the local energy deposition method can lead to results in line with those obtained by Monte Carlo calculations.

6 March 2026 in Current Oncology
Verified
Journal Article
Open access
PDF file
RCRoberto Castellana
Roberto Castellana
SMSimona Marzi
Simona Marzi
ARAndrea Russo
Andrea Russo
MFMaria Consiglia Ferriero
Maria Consiglia Ferriero
Irene TerrenatoIrene Terrenato
Irene Terrenato
LBLuca Bertini
Luca Bertini
Background: Multiparametric MRI is central to detecting clinically significant prostate cancer (csPCa), but diagnostic accuracy depends on reader experience. Artificial intelligence (AI) tools may support prostate MRI interpretation and reduce inter-reader variability. This study compared the detection rate of a trial, non-commercial version an AI-based software (PAROS) with that of an experienced radiologist. Methods: This retrospective single-center study included 150 patients who underwent prostate MRI followed by combined systematic and MRI-targeted transperineal biopsy. MRI examinations were interpreted by an experienced radiologist according to PI-RADS v2.1 and independently analyzed using a precommercial trial version of PAROS operating on biparametric MRI. Histopathology served as the reference standard. Detection rate was evaluated using sensitivity, specificity, and positive and negative likelihood ratios (PLR and NLR) at PI-RADS thresholds ≥3 and ≥4. Results: CsPCa was present in 63.3% of patients. At both PI-RADS thresholds, PAROS and the radiologist showed comparable sensitivity and specificity, wuth extremely low NLRs, indicating excellent rule-out capability. PLRs were modest and similar at PI-RADS ≥ 3 (1.26 vs. 1.42) and 1.88 for both at PI-RADS ≥ 4. PAROS detected more lesions, particularly in the transition zone. Conclusions: PAROS achieved csPCa detection comparable to an experienced radiologist, supporting its role as a decision-support tool in prostate MRI interpretation.