Radio-ligand therapy (RLT) with177Lu-PSMA-617 is a promising option for patients with metastatic castration-resistant prostate-cancer (mCRPC). A prospective phase-II study (EUDRACT/RSO,2016-002732-32) on mCRPC is ongoing at IRST (Meldola, Italy). A total of 9 patients (median age: 68 y, range: 53–85) were enrolled for dosimetry evaluation of parotid glands (PGs), kidneys, red marrow (RM) and whole body (WB). Folic polyglutamate tablets were orally administered as PGs protectors and 500 mL of a 10% mannitol solution was intravenously infused to reduce kidney uptake. The whole body planar image (WBI) and blood samples were acquired at different times post infusion (1 h, 16–24 h, 36–48 h and 120 h). Dose calculation was performed with MIRD formalism (OLINDA/EXM software). The median effective half-life was 33.0 h (range: 25.6–60.7) for PGs, 31.4 h (12.2–80.6) for kidneys, 8.2 h (2.5–14.7) for RM and 40.1 h (31.6–79.7) for WB. The median doses were 0.48 mGy/MBq (range: 0.33–2.63) for PGs, 0.70 mGy/MBq (0.26–1.07) for kidneys, 0.044 mGy/MBq (0.023–0.067) for RM and 0.04 mGy/MBq (0.02–0.11) for WB. A comparison with previously published dosimetric data was performed and a significant difference was found for PGs while no significant difference was observed for the kidneys. For PGs, the possibility of reducing uptake by administering glutamate tablets during RLT seems feasible while further research is warranted for a more focused evaluation of the reduction in kidney uptake.
The purpose of this study is to investigate the optimal reference geometry for gamma camera calibration. Yet another question of interest was to assess the influence of the number of 3D Ordered Subsets Expectation Maximization (3D-OSEM) updates on activity quantification for SPECT imaging with 177Lu. The accuracy of 177Lu activity quantification was assessed both in small and in large objects. Two different reference geometries, namely a cylindrical homogeneous phantom and a Jaszczak 16 ml sphere surrounded by cold water, were used to determine the gamma camera calibration factor of a commercial SPECT/CT system. Moreover, the noise level and the concentration recovery coefficient were evaluated as a function of the number of 3D-OSEM updates by using the SPECT/CT images of the reference geometry phantoms and those of a cold Jaszczak phantom with three hot spheres (16ml, 8ml and 4ml), respectively. The optimal choice of the number of 3D-OSEM updates was based on a compromise between the noise level achievable in the reconstructed SPECT images and the concentration recovery coefficients. The quantitative accuracy achievable was finally validated on a test phantom, where a spherical insert composed of two concentric spheres was used to simulate a lesion in a warm background. Our data confirm and extend previous observations. Using the calibration factor obtained with the cylindrical homogeneous phantom and the Jaszczak 16 ml sphere, the recovered activity in the test phantom was underestimated by -16.4% and -24.8%, respectively. Our work has led us to conclude that gamma camera calibration performed with large homogeneous phantom outperforms calibration executed with the Jaszczak 16ml sphere. Furthermore, the results obtained support the assumption that approximately 50 OSEM updates represent a good trade-off to reach convergence in small volumes, meanwhile minimizing the noise level.
The purpose of this study was to retrospectively evaluate the results from a Helical TomoTherapy Hi-Art treatment system relating to quality controls based on daily static and dynamic output checks using statistical process control methods. Individual value X-charts, exponentially weighted moving average charts, and process capability and acceptability indices were used to monitor the treatment system performance. Daily output values measured from January 2014 to January 2015 were considered. The results obtained showed that, although the process was in control, there was an out-of-control situation in the principal maintenance intervention for the treatment system. In particular, process capability indices showed a decreasing percentage of points in control which was, however, acceptable according to AAPM TG148 guidelines. Our findings underline the importance of restricting the acceptable range of daily output checks and suggest a future line of investigation for a detailed process control of daily output checks for the Helical TomoTherapy Hi-Art treatment system.
Objectives: To determine interobserver variability in axillary nodal contouring in breast cancer (BC) radiotherapy (RT) by comparing the clinical target volume of participating single centres (SC-CTV) with a gold-standard CTV (GS-CTV). Methods: The GS-CTV of three patients (P1, P2, P3) with increasing complexity was created in DICOM format from the median contour of axillary CTVs drawn by BC experts, validated using the simultaneous truth and performance-level estimation and peer-reviewed. GS-CTVs were compared with the correspondent SC-CTVs drawn by radiation oncologists, using validated metrics and a total score (TS) integrating all of them. Results: Eighteen RT centres participated in the study. Comparative analyses revealed that, on average, the SC-CTVs were smaller than GS-CTV for P1 and P2 (by −29.25% and −27.83%, respectively) and larger for P3 (by +12.53%). The mean Jaccard index was greater for P1 and P2 compared to P3, but the overlap extent value was around 0.50 or less. Regarding nodal levels, L4 showed the highest concordance with the GS. In the intra-patient comparison, L2 and L3 achieved lower TS than L4. Nodal levels showed discrepancy with GS, which was not statistically significant for P1, and negligible for P2, while P3 had the worst agreement. DICE similarity coefficient did not exceed the minimum threshold for agreement of 0.70 in all the measurements. Conclusions: Substantial differences were observed between SC- and GS-CTV, especially for P3 with altered arm setup. L2 and L3 were the most critical levels. The study highlighted these key points to address. Advances in knowledge: The present study compares, by means of validated geometric indexes, manual segmentations of axillary lymph nodes in breast cancer from different observers and different institutions made on radiotherapy planning CT images. Assessing such variability is of paramount importance, as geometric uncertainties might lead to incorrect dosimetry and compromise oncological outcome.
The DirectDensity® CT reconstruction algorithm provides a reconstruction approach independent of the tube voltage, directly reconstructing the CT projection data into CT numbers related to the electron densities of the materials. This work examines the efficacy of DirectDensity® in the treatment planning process with both tissues and metallic materials. CT scans of a Cheese phantom were acquired at 80, 100, 120 and 140 kVp and reconstructed with different algorithms. Calibration curves were built for each kVp and reconstruction technique. To evaluate the flexibility of the DirectDensity® in dose calculations, a prostate cancer treatment plan was simulated on phantom images with and without metal inserts. Moreover, the robustness of the algorithm was tested by simulating a possible error in the selection of the calibration curve. As expected, the calibration curves related to DirectDensity® showed a tube voltage dependence only for densities above 1.82 g/cm3. The maximum percentage differences in dose distributions comparations never exceeded the 3% of tolerance and the 3D gamma analysis always returned indices greater than 90%. The results suggest that the DD reconstruction algorithm can be employed in most clinical cases and allows for a personalized radiotherapy cancer treatment workflow, maintaining its robustness and simplicity.
At a time of increasing evidence for dose-effect relationships in radioembolization (RE) with 90Y-microspheres, the general consensus is that there is an urgent need for accurate treatment planning and dose assessment in patients undergoing RE treatment. This work aimed at assessing the usefulness of 99mTc macroaggregated albumin (MAA) SPECT/CT imaging for personalized provisional RE dosimetry considering a 3D-printed patientlike phantom (AdboMan phantom). A homemade tool was developed in MATLAB for image analysis and absorbed dose calculation. Two dose calculaton methods were implemented and used to calculate dose volume histograms: (I) dose kernel method and (II) local energy deposition method. The accuracy of the two different dosimetric methods was evaluated by means of 3D -index (1%–1 mm and 2%–2 mm) implemented in the tool. Differences between the two dose calculation methods using the 3D -index are within 1%–1 mm and 2%–2 mm for all AbdoMan inserts, with a passing rate of 99.9% and 100%, respectively, proving a good agreement between the two calculation methods. The present study supports the use of 99mTc-MAA SPECT acquisition for provisional dosimetry along with the local energy deposition method to convert reconstructed SPECT data into absorbed dose maps. As long as 99mTc-MAA SPECT acquisitions are performed on liver lesions larger than 40 mm, the absorbed dose computed by means of the local energy deposition method can lead to results in line with those obtained by Monte Carlo calculations.