Over the last few decades, the need to reduce and optimize patient medical radiation exposure has prompted the introduction of novel reconstruction algorithms in computed tomography (CT). Against this backdrop, the present study aimed to assess whether reduced radiation dose CT images reconstructed with the new-generation adaptive statistical iterative reconstruction (ASiR-V) maintain the same image quality as that of routine image reconstruction. In addition, the optimization of image quality parameters for the ASiR-V algorithm (e.g., an optimal combination of blending percentage and noise index (NI)) was investigated. An abdominal reference phantom was imaged using the routine clinical protocol (fixed noise index of 18 and 40% ASiR reconstruction). Reduced radiation dose CT scans were performed with varying NI (22, 24, and 30) and using the ASiR-V reconstruction algorithm. Quantitative and qualitative analyses of image noise, contrast, and resolution were performed against NI and reconstruction blending percentages. Our results confirm the ability of the ASiR-V algorithm to provide images of high diagnostic quality while reducing the patient dose. All the parameters were improved in ASiR-V images as compared to ASiR. Both quantitative and qualitative analyses showed that the best agreement was obtained for the images reconstructed using ASiR-V with NI24 and a high percentage of blending (70–100%). This preliminary study results show that ASiR-V allows for a significant reduction in patient dose (about 40%) while maintaining a good overall image quality when appropriate NI (i.e., 24) is used.
The Sorgentina-RF project will use fusion neutrons to produce 99Mo, a precursor of 99mTc, by irradiating natural molybdenum. 99Mo is produced by means of the inelastic reaction 100Mo(n, 2n)99Mo on 100Mo, which is an isotope of natural Mo. From a functional point of view, the project consists of two parts: an irradiation neutron source at 14 MeV and a radiochemistry facility dedicated to the extraction of 99Mo from the solid sample irradiated by the neutron source. Given the degree of complexity of such a facility, the risk management strategy is based on an integrated approach that combines the engineering method of safety with that of radiation protection. Therefore, design issues were studied and systems were planned according to both radiation protection and safety criteria already in the preliminary phase, allowing a general strengthening of the safety of the plant. This work discusses the preventive analysis and the related activities to identify the ways in which potential exposures to radiation may occur. In particular, the preliminary safety analysis is presented for the innovative rotating target, developed for the project, and, accordingly, some specific technical solutions are given to refine the initial design of the facility.
At a time of increasing evidence for dose-effect relationships in radioembolization (RE) with 90Y-microspheres, the general consensus is that there is an urgent need for accurate treatment planning and dose assessment in patients undergoing RE treatment. This work aimed at assessing the usefulness of 99mTc macroaggregated albumin (MAA) SPECT/CT imaging for personalized provisional RE dosimetry considering a 3D-printed patientlike phantom (AdboMan phantom). A homemade tool was developed in MATLAB for image analysis and absorbed dose calculation. Two dose calculaton methods were implemented and used to calculate dose volume histograms: (I) dose kernel method and (II) local energy deposition method. The accuracy of the two different dosimetric methods was evaluated by means of 3D -index (1%–1 mm and 2%–2 mm) implemented in the tool. Differences between the two dose calculation methods using the 3D -index are within 1%–1 mm and 2%–2 mm for all AbdoMan inserts, with a passing rate of 99.9% and 100%, respectively, proving a good agreement between the two calculation methods. The present study supports the use of 99mTc-MAA SPECT acquisition for provisional dosimetry along with the local energy deposition method to convert reconstructed SPECT data into absorbed dose maps. As long as 99mTc-MAA SPECT acquisitions are performed on liver lesions larger than 40 mm, the absorbed dose computed by means of the local energy deposition method can lead to results in line with those obtained by Monte Carlo calculations.
Molecular Radiation Therapy (MRT) is a valid therapeutic option for a wide range of malignancies, such as neuroendocrine tumors and liver cancers. In its practice, it is generally acknowledged that there is a need to evaluate the influence of different factors affecting the accuracy of dose estimates and to define the actions necessary to maintain treatment uncertainties at acceptable levels. The present study addresses the problem of uncertainty propagation in 90Y-PET quantification. We assessed the quantitative accuracy in reference conditions of three PET scanners (namely, Siemens Biograph mCT, Siemens Biograph mCT flow, and GE Discovery DST) available at three different Italian Nuclear Medicine centers. Specific aspects of uncertainty within the quantification chain have been addressed, including the uncertainty in the calibration procedure. A framework based on the Guide to the Expression of Uncertainty in Measurement (GUM) approach is proposed for modeling the uncertainty in the quantification processes, and ultimately, an estimation of the uncertainty achievable in clinical conditions is reported.
6 September 2024 in The European Physical Journal Plus
Radioembolization (RE) with 90Y-microspheres has gained widespread acceptance as a safe and effective technique for treating liver malignancies. Accurate quantification in RE is a key step in treatment planning optimization and is becoming a pressing issue in light of the Directive 2013/59/EURATOM. The aim of this study was to develop a SPECT/CT imaging protocol for quantitative imaging optimization in RE based on cutting edge imaging technology (Symbia IntevoTM system provided with the innovative xSPECT software) and a novel anthropomorphic 3D-printed phantom. In the present study, 99mTc-labeled macroaggregated albumin was used as a surrogate radiopharmaceutical for treatment planning. Gamma camera calibration factors and recovery coefficients were determined performing preliminary SPECT/CT acquisitions of a point source, a cylindrical homogeneous phantom and the NEMA/IEC phantom. Data reconstruction was performed using the built-in xSPECT package, using both the Ordered Subset Expectation–Maximization (OSEM) and the Ordered Subset Conjugated Gradient (OSCG) algorithm. Specific regions of interest (ROIs) were drawn on the MIM 6.1.7 system according to the physical volume. The quantification procedure was validated using the anthropomorphic phantom provided with a fillable liver section and spheres of different diameters (20 mm, 40 mm and a 40 mm spherical shell). The measured activity concentration in all geometries is consistent within 4%, demonstrating that the xSPECT software permit an absolute quantification in anthropomorphic geometry largely within the 10% recommended from the manufacturer. Caution is advised in the presence of spherical objects with a necrotic core, as underestimations in the order of 20% were obtained.