Zvi משה Gutmacher

Dr. Zvi משה Gutmacher

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

20 February 2014 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
ZGZvi משה Gutmacher
Zvi משה Gutmacher
GLGuy Levi
Guy Levi
IBIsrael Blumenfeld
Israel Blumenfeld
EMEli E. Machtei
Eli E. Machtei

23 April 2026 in International Dental Journal
Verified
Journal Article
Open access
Yaniv MayerYaniv Mayer
Yaniv Mayer
RCRambam health care campus
Rambam health care campus
SJSamah Jazmawi
Samah Jazmawi
YSYaniv Skvirsky
Yaniv Skvirsky
TMTarek health care Mtanis
Tarek health care Mtanis
ZGZvi משה Gutmacher
Zvi משה Gutmacher
Artificial intelligence (AI) is increasingly used for dental radiographic interpretation, yet the effect of image resolution on diagnostic accuracy compared with human evaluators remains unclear. This study evaluated how medium- versus high-resolution full-mouth radiographs influence diagnostic performance of an AI system and experienced clinicians. In this retrospective comparative study, 200 full-mouth series radiographs were divided equally into medium-resolution (96-300 dpi) and high-resolution (≥720 dpi) groups. Three independent human examiners and an AI system (Diagnocat, San Francisco, CA, USA) assessed six pathological conditions. The reference standard was defined as agreement between at least two human examiners. Diagnostic metrics (sensitivity, specificity, predictive values, accuracy, F1-score) were calculated with 95% confidence intervals. Inter- and intra-examiner reliability and AI-human agreement were assessed using Cohen's kappa. Differences in diagnostic accuracy between resolutions were tested using chi-square tests for independent proportions (or Fisher's exact test where appropriate), with Bonferroni correction for multiple comparisons. Human inter-examiner agreement ranged from moderate to substantial across pathologies (κ = 0.27-0.87), with the highest agreement for missing teeth and the lowest for root resorption. AI-gold standard agreement varied from essentially none to substantial (κ = 0.00-0.90) and increased with higher resolution for most conditions. AI accuracy ranged from 75.3% to 99.1%, with consistently high specificity (73.5%-99.8%) and variable sensitivity (0.0%-93.6%). High-resolution imaging significantly improved AI diagnostic accuracy for caries (+4.3%), furcation involvement (+1.4%), dental calculus (+9.8%), and missing teeth (+3.9%) (all P < .001, after Bonferroni correction), while changes for periapical lesions and root resorption were not significant. High-resolution radiographs enhance diagnostic accuracy for AI and human evaluators. AI achieved clinically acceptable performance, though sensitivity differed across pathologies. High resolution full mouth radiographs improve diagnostic accuracy for both artificial intelligence and human evaluators. This finding underscores the importance of optimal image quality in clinical practice to enhance diagnostic confidence and support AI assisted decision making in dentistry.

17 April 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Tahel AlonTahel Alon
Tahel Alon
LBLeon Bilder
Leon Bilder
HZHadar Zigdon-Giladi
Hadar Zigdon-Giladi
ZGZvi משה Gutmacher
Zvi משה Gutmacher
Yaniv MayerYaniv Mayer
Yaniv Mayer
This study highlights the oral health condition of female sex workers (SWs), who face increased risks associated with habits such as excessive alcohol and tobacco use. These behaviors heighten the likelihood of issues like oral cancer and dental diseases, underscoring the need for targeted health interventions. The study examines the oral health disparities between SWs and the general population (GP). A retrospective study analyzed the health records of 40 SWs and 40 controls matched by age and gender who were examined between 1 January 2020 and 30 May 2023. Intra-oral and panoramic radiographs, alongside clinical examination, were used to evaluate missing teeth, periodontal bone support, and caries. T-tests and chi-square tests were used to compare dental health indicators. A comparative analysis of these 80 patients revealed significant disparities: SWs had a higher incidence of missing teeth (5.8 ± 7.3 vs. 0.7 ± 1.4, p < 0.01) and caries (6.1 ± 6.2 vs. 0.8 ± 1.2, p < 0.05) compared to the GP. The DMFT (Decayed, Missing, and Filled Teeth) index was notably higher in SWs (16.1 ± 8.09) than in the GP (7.95 ± 5.48, p < 0.001). Additionally, 12% of SWs used removable dentures, unlike the GP. This study underscores significant oral health challenges in SWs, emphasizing the need for targeted healthcare strategies to improve their health conditions.

30 July 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MBMatan Barkan
Matan Barkan
YSYaniv Skvirsky
Yaniv Skvirsky
IGIlan Gilboa
Ilan Gilboa
DADror Aizenbud
Dror Aizenbud
EMEli Eliahu Machtei
Eli Eliahu Machtei
ZGZvi משה Gutmacher
Zvi משה Gutmacher
Background/Objectives: Controlled tightening force of implant prosthetic screws is achieved using dental torque wrenches. Beam-type wrenches are prone to a parallax error, where different viewing angles can unintentionally alter the applied force, potentially leading to screw loosening and fracture. The objective of this study was to determine the effect of different viewing angles of the operator relative to the wrench’s reading scale and the actual force applied on the prosthetic screw. Methods: Two types of beam torque wrenches (Institut Straumann AG, Switzerland; MIS Implant Technologies, Israel) were used. Five wrenches for each group were connected to a torque meter mounted on a custom 3D printed apparatus, allowing torque read at different viewing angles. Each wrench was tightened according to manufacturer recommendations at angles ranging between ±60 degrees from center position. A camera mounted on a tripod provided magnification and consistency in recordings. For each measurement, a comparison was made between intended tightening force and actual force exerted on the torque meter. Data were analyzed to determine the effect on clinical settings. Results: Both wrenches exhibited a parallax effect with its resulting impact on force delivery by the wrench. When the operator was positioned at a negative angle relative to the wrench, while applying tightening force, the actual force delivered by the wrench was amplified. The greater the angle, the greater the force amplification was. The opposite effect took place when the wrench was viewed from a positive angle relative to the operator. Force alteration reached up to 8.72 Ncm, which can account for as much as 25% from intended force. This effect was notable and statistically significant for both types of wrenches. Conclusions: The tested beam-type torque wrenches present an inherent potential deficiency in which oblique viewing angles lead to either amplification or attenuation of the actual force that is applied. This phenomenon might be associated with a variety of prosthetic failures. Operators are recommended to adopt a viewing strategy that minimizes undesired outcomes.

5 June 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Ofir GinesinOfir Ginesin
Ofir Ginesin
SBShiran Barsheshet-Karif
Shiran Barsheshet-Karif
Yaniv MayerYaniv Mayer
Yaniv Mayer
RCRambam health care campus
Rambam health care campus
YBYotam Bar-On
Yotam Bar-On
ZGZvi משה Gutmacher
Zvi משה Gutmacher
Background: Peri-implantitis is a prevalent inflammatory condition leading to progressive bone loss around dental implants. In vivo studies widely use murine peri-implantitis models. Micro-computed tomography (micro-CT) is the gold standard method used to assess peri-implant bone changes in those models. However, no standardized protocol exists for image analysis, limiting comparability across studies. Objective: This study aimed to evaluate the effect of different micro-CT analysis parameters on bone measurements in a ligature-induced peri-implantitis mouse model. Methods: Seventeen C57BL/6J mice were divided into peri-implantitis (n = 8) and healthy (n = 9) groups. Following extraction and implant placement in the maxillary first molar region, peri-implantitis was induced via silk ligature placement. Micro-CT scans were analyzed by varying the volume of interest (VOI) size (2-thread vs. 5-thread spans), threshold values for bone and implant visualization, and measurement dimensionality (2D linear vs. 3D volumetric). Statistical significance (p < 0.05) was determined using unpaired t-tests or Mann–Whitney U tests, following Shapiro–Wilk normality assessment. Results: The 2-thread VOI yielded a highly significant difference in bone volume fraction (BV/TV) between groups (68.86 ± 4.97% vs. 50 ± 4.32%, p < 0.0001, Cohen’s d = 4.05), while the 5-thread VOI showed no significant difference. Thresholds of 60 and 200 were utilized for bone and implant segmentation, respectively, selected based on high inter-examiner reliability (Cohen’s kappa = 0.844 and 0.825, respectively). Two-dimensional analysis confirmed greater mesio-distal loss in the peri-implantitis group. Conclusions: A 2-thread coronal VOI combined with optimized thresholds provides a promising analytical approach for evaluating localized peri-implant bone changes in this exploratory model. While this approach demonstrated pronounced responsiveness within our dataset, further external validation across different imaging systems and operators is required to establish its role as a universal standard.