Background/Objectives: Controlled tightening force of implant prosthetic screws is achieved using dental torque wrenches. Beam-type wrenches are prone to a parallax error, where different viewing angles can unintentionally alter the applied force, potentially leading to screw loosening and fracture. The objective of this study was to determine the effect of different viewing angles of the operator relative to the wrench’s reading scale and the actual force applied on the prosthetic screw. Methods: Two types of beam torque wrenches (Institut Straumann AG, Switzerland; MIS Implant Technologies, Israel) were used. Five wrenches for each group were connected to a torque meter mounted on a custom 3D printed apparatus, allowing torque read at different viewing angles. Each wrench was tightened according to manufacturer recommendations at angles ranging between ±60 degrees from center position. A camera mounted on a tripod provided magnification and consistency in recordings. For each measurement, a comparison was made between intended tightening force and actual force exerted on the torque meter. Data were analyzed to determine the effect on clinical settings. Results: Both wrenches exhibited a parallax effect with its resulting impact on force delivery by the wrench. When the operator was positioned at a negative angle relative to the wrench, while applying tightening force, the actual force delivered by the wrench was amplified. The greater the angle, the greater the force amplification was. The opposite effect took place when the wrench was viewed from a positive angle relative to the operator. Force alteration reached up to 8.72 Ncm, which can account for as much as 25% from intended force. This effect was notable and statistically significant for both types of wrenches. Conclusions: The tested beam-type torque wrenches present an inherent potential deficiency in which oblique viewing angles lead to either amplification or attenuation of the actual force that is applied. This phenomenon might be associated with a variety of prosthetic failures. Operators are recommended to adopt a viewing strategy that minimizes undesired outcomes.
Background: The aim of this study was to examine publication bias associated with a failure to report research results of studies that were initially posted on the ClinicalTrials.gov registry and to examine factors associated with this phenomenon. Methods: A search was conducted in the ClinicalTrials.gov registry using six dental-related topics. Corresponding publications for trials completed between 2016 and 2019 were then searched using PUBMED, EMBASE and Google Scholar. For studies lacking matching publications, we emailed the primary investigator and received some additional data. For included studies, we recorded additional variables: industry funding, site setting (academic, private research facilities or private practice), design (single or multi-center), geographical location and commencement date vis a vis registration and publication dates. Results: A total of 744 entries were found, of which 7 duplicates were removed; an additional 67 entries just recently completed were removed. An additional 7 studies were in different fields and thus removed. Thus, 663 trials were included; of these, only 337 studies (50.8%) were published. The mean registration to publication interval was 29.01 ± 25.7 months, ranging from +142 to −34 months (post factum registration). Less than 1/3 of the studies were posted prior to commencement, of which much smaller proportions were published (37.3%). Studies that were posted after commencement (n = 462) had a much higher publication rate (56.7%), p < 0.001. Multi-center studies and those conducted in commercial facilities had much higher, though non-significant, publication rates (56.5% and 58.3%, respectively). Conclusions: With only half of the studies registered being published, a major source for publication bias is imminent.