Background and Objectives: Dental models are essential for diagnosis and prosthetic treatment planning and have traditionally been fabricated from gypsum. With the growing adoption of digital workflows, 3D-printed dental models are increasingly used; however, concerns remain regarding their dimensional stability over time. This study evaluated the temporal dimensional changes of gypsum and 3D-printed dental models under different storage conditions and assessed the uniformity of these changes across the models. Methods: A fully dentate maxillary typodont was scanned to create a reference model. Sixteen gypsum casts (Type IV dental stone) and 48 3D-printed models from three materials were fabricated. Models were stored at either 4 °C or room temperature and rescanned at predefined intervals over 28 days. Dimensional accuracy was analyzed using 3D inspection software (Geomagic Control X 2022.1.0), with trueness measured by root mean square deviation and precision by standard deviation across the full arch and five predefined regions. Statistical analysis was performed using a Bayesian hierarchical linear model, with significance set at pd > 97.5%. Results: Printed models demonstrated significantly higher precision than gypsum models at baseline and day 28 under both storage conditions, with no significant differences among printed materials. In terms of trueness, selected printed groups showed lower deviations than gypsum at baseline, while one material exhibited the best performance at day 28. Gypsum models remained relatively stable over time, whereas printed models showed time-dependent, region-specific dimensional changes, primarily in posterior regions, with maximum deviations of up to 0.026 mm. Conclusions: 3D-printed dental models exhibit limited but nonuniform dimensional changes over time, while gypsum models remain comparatively stable. Localized distortions, particularly in posterior regions, should be considered when printed models are used for precise prosthetic applications.
Background/Objectives: Controlled tightening force of implant prosthetic screws is achieved using dental torque wrenches. Beam-type wrenches are prone to a parallax error, where different viewing angles can unintentionally alter the applied force, potentially leading to screw loosening and fracture. The objective of this study was to determine the effect of different viewing angles of the operator relative to the wrench’s reading scale and the actual force applied on the prosthetic screw. Methods: Two types of beam torque wrenches (Institut Straumann AG, Switzerland; MIS Implant Technologies, Israel) were used. Five wrenches for each group were connected to a torque meter mounted on a custom 3D printed apparatus, allowing torque read at different viewing angles. Each wrench was tightened according to manufacturer recommendations at angles ranging between ±60 degrees from center position. A camera mounted on a tripod provided magnification and consistency in recordings. For each measurement, a comparison was made between intended tightening force and actual force exerted on the torque meter. Data were analyzed to determine the effect on clinical settings. Results: Both wrenches exhibited a parallax effect with its resulting impact on force delivery by the wrench. When the operator was positioned at a negative angle relative to the wrench, while applying tightening force, the actual force delivered by the wrench was amplified. The greater the angle, the greater the force amplification was. The opposite effect took place when the wrench was viewed from a positive angle relative to the operator. Force alteration reached up to 8.72 Ncm, which can account for as much as 25% from intended force. This effect was notable and statistically significant for both types of wrenches. Conclusions: The tested beam-type torque wrenches present an inherent potential deficiency in which oblique viewing angles lead to either amplification or attenuation of the actual force that is applied. This phenomenon might be associated with a variety of prosthetic failures. Operators are recommended to adopt a viewing strategy that minimizes undesired outcomes.