With the increasing consumption of electric energy, how to improve the capacity of transmission lines within safe margins is an urgent problem to be solved. This paper presents a transient thermal rating method under real-time meteorological conditions. The result of thermal ratings under different conditions shows that this rating approach can significantly increase the capacity of the line. As some of the most critical variables are remaining time and initial temperature, their influence upon the rating is studied. The method of statistical analysis is used to determine the ampacity at different risk levels. The result indicates that with smaller remaining time, the ampacities are larger, and with larger ampacities, the risk of thermal overload is greater. The choice of risk level would heavily affect the values of ampacity.
It is difficult to consider factors such as wind speed, water flow velocity, and solar radiation when using the IEC 60287 standard to calculate the current-carrying capacity of shore power cables in port microgrids. Therefore, based on the equivalent thermal circuit model and heat balance equation, this research takes solar radiation as the heat source of the cable used in port microgrids and proposes a mathematical calculation method for the current-carrying capacity of shore power cables based on the Newton–Raphson method. The influence of wind and water speed, environmental temperature, and solar radiation on current-carrying capacity is compared and analyzed using this mathematical calculation method and simulation calculation method. Shore power cables exhibit higher ampacity in water than air due to water’s superior thermal conductivity. Maximum ampacity difference occurs at 0.17 m/s flow (26.8 A analytically) and 0.066 m/s flow (64.4 A simulation). Air-laid cables show amplified ambient temperature effects from solar radiation, while water-laid cables demonstrate near-linear ampacity variations (Δ40 °C: 0–40 °C temperature range). This research can provide a reference for the revision of the standard for calculating the current-carrying capacity of shore power cables and optimizing renewable-energy-integrated port power systems.
To save land resources, the construction of the high-voltage direct current (HVDC) and high-voltage alternating current (HVAC) hybrid transmission lines in the same corridor is inevitable. To provide suggestions for the construction of the AC/DC parallel lines, the hybrid ionized field of AC/DC transmission lines was calculated by the meshless local Petorv–Galerkin (MLPG) method for the first time. In this method, the radius of local sub-domain is adjusted to the nodes close to the global boundary, but not exactly on the boundary. It can avoid the boundary integral, as well as having simplified calculation. The method was validated by comparing with measured results and calculation results. The MLPG method is beneficial to obtaining high-precision results by constructing the more complex shape function. Finally, a field distribution of the parallel line of about ±800 kV DC/500 kV AC was calculated. Moreover, the influence of different parallel spacing and AC voltage level on the hybrid ionized field was analyzed, which provides theoretical basis for real parallel lines design.
In the context of new-type power system construction, digital twin has become the core technology for power transformers, supporting their full-life cycle intelligent operation and maintenance. The real-time, high-precision calculation of the internal temperature field serves as the core supporting element for realizing the real-time mapping between the physical transformer entity and its virtual twin. Aiming at the inherent defects of traditional temperature rise calculation methods, such as insufficient accuracy and an excessively long computation time, this paper proposes a simplified calculation model for the transformer temperature field. In this model, the transformer oil tank is simplified into a two-dimensional axisymmetric thermal–fluid coupled field model solved by the finite volume method (FVM). The Proper Orthogonal Decomposition (POD) technique is adopted to perform order reduction on the matrices involved in the governing equations, so as to reduce the computational degrees of freedom. Meanwhile, the radiator is equivalent to a one-dimensional thermal circuit model, and the field–circuit coupled solution is achieved through bidirectional data mapping. Temperature field calculation is carried out for a 220 kV oil-immersed transformer based on the proposed model. The results show that the average relative error between the calculated results and the experimental data is around 0.86%, while the computation time is merely 0.04% of that of the traditional three-dimensional full-scale model. Furthermore, taking the real-time overload capacity evaluation of the transformer as a case, it is verified that the proposed model can successfully support the requirements of practical engineering applications.
To address the inverse identification of contact-related thermal faults in gas-insulated switchgear (GIS), this study proposes a method for contact resistance inversion and internal temperature field reconstruction. The proposed method enables the estimation of faulty internal contact resistance using external enclosure temperature data, while simultaneously reconstructing the internal temperature field. First, a forward numerical model of GIS is established, and a POD-Kriging surrogate model is developed to achieve second-level rapid prediction of the forward problem. Based on this surrogate model, the thermal fault inversion problem is formulated as an optimization problem of fault parameters and solved using the Grey Wolf Optimizer. GIS temperature-rise experiments are performed to validate the numerical model, and a real GIS contact fault case is further analyzed. The results indicate that the proposed method yields an average inversion error of 9.5% for degraded contact resistance, with the maximum error at internal temperature monitoring points remaining below 8%. The total inversion time is approximately 30 s. These findings demonstrate that the proposed method is capable of effective online inversion and diagnosis of contact-related thermal faults in GIS equipment.