7 December 2021 in Biomedical Optics Express
We present deep convolutional neural network (DCNN)-based estimators of the tissue scatterer density (SD), lateral and axial resolutions, signal-to-noise ratio (SNR), and effective number of scatterers (ENS, the number of scatterers within a resolution volume). The estimators analyze the speckle pattern of an optical coherence tomography (OCT) image in estimating these parameters. The DCNN is trained by a large number (1,280,000) of image patches that are fully numerically generated in OCT imaging simulation. Numerical and experimental validations were performed. The numerical validation shows good estimation accuracy as the root mean square errors were 0.23%, 3.65%, 3.58%, 3.79%, and 6.15% for SD, lateral and axial resolutions, SNR, and ENS, respectively. The experimental validation using scattering phantoms (Intralipid emulsion) shows reasonable estimations. Namely, the estimated SDs were proportional to the Intralipid concentrations, and the average estimation errors of lateral and axial resolutions were 1.36% and 0.68%, respectively. The scatterer density estimator was also applied to an in vitro tumor cell spheroid, and a reduction in the scatterer density during cell necrosis was found.
1 January 2014 in Journal of Nanophotonics
Enhanced third-harmonic generation in a one-dimensional photonic crystal doped with third-order nonlinear medium was numerically investigated using the multiple-scale method and the split-step Fourier transform. The optimal fundamental frequency for third-harmonic wave generation was determined from the transmission spectrum. The third-harmonic pulse intensities grow, depending on the structure thickness and the fundamental-frequency detuning parameter, which determines the band-edge phase matching condition. Furthermore, the total energy output of third-harmonic pulses, depending on the fundamental-frequency pulse width, may be more than 1000 times the energy produced by a phase-matched bulk medium. A narrow pulse with bandwidth less than the band-edge transmission peak enables high conversion efficiency. The maximum conversion efficiency of the forward component may be 12 to 13 orders of magnitude greater than that of the backward component.
18 March 2024 in Applied Optics
We review Fourier-domain methods for demosaicking Bayer-filter color cameras and monochrome polarization cameras, and then generalize the approach for the quad-Bayer-filter mosaic and for color-polarization cameras. For each of these four mosaic filter types, we provide theoretical expressions for the sampling functions, the Fourier-domain channels, and the linear combination of reconstructed channels (the demosaicking algorithm) needed to estimate the input (presampled) image. A useful advantage of the Fourier-domain approach is that it provides a direct means of visualizing and quantifying when aliasing is likely or unlikely to be present. For the Bayer and quad-Bayer-filter types, we provide simulated images, while for the polarization camera types we provide experimental images and videos to illustrate the algorithm and analyze crosstalk error.
25 June 2014 in Optical Engineering
Total internal reflection (TIR) is normally important in an optical fingerprint scanner. The moisture effect in a fingerprint scanner based on TIR has been explored by using digital in-line holography (DIH). First, the reflection and the transmission technique set up for DIH have been explored by using a positive resolution test target with a line width of 200 μm. From experimental results, the reconstructed image of the reflected DIH is perfect as the image of the transmitted DIH. Due to the advantage for opaque object imaging of the reflected DIH, reflected DIH based on TIR has been selected to investigate the moisture effect of the fingerprint. Fingerprints with moistures of 39%, 54%, 69%, and a soaked finger have been observed. A laser diode of 635 nm and a complementary metal oxide semiconductor camera were used in all of the experimental setups in this research. The reconstructed image of the fingerprint gives a sharper image than the directed recorded image. The fingerprint with higher moisture provided a darker fingerprint image, while the optimum amount of moisture that gives the most complete finger pattern is 54%.
1 December 2021 in Radiation Physics and Chemistry
29 January 2024 in Applied Optics
This work has implemented a diverse modification of the Sagnac interferometer to accommodate various measurement requirements, including phase shifting, pattern recognition, and a morphological analysis. These modifications were introduced to validate the adaptability and versatility of the system. To enable phase shifting using the multiple light reflection technique, a half-wave plate (HWP) was utilized with rotations at 0, π/8, π/4, and 3π/8 radians, generating four interference patterns. It is possible to observe a distinct circular fringe width as the polarized light experiences diffraction at the interferometer’s output as it travels through a circular aperture with various diameters ranging from 0.4 to 1 mm. Further modifications were made to the setup by inserting a pure glass and a fluoride-doped tin oxide (FTO) transparent substrate into the common path. This modification aimed to detect and analyze a horizontal fringe pattern. Subsequently, the FTO substrate was replaced with a bee leg to facilitate morphology recognition. A deep learning-based image processing technique was employed to analyze the bee leg morphology. The experimental results showed that the proposed scheme succeeded in achieving the phase shift, measuring hole diameters with errors smaller than 1.6%, separating distinct transparent crystals, and acquiring the morphological view of a bee’s leg. The method also has successfully achieved an accurate surface area and background segmentation with an accuracy over 87%. Overall, the outcomes demonstrated the potential of proposed interferometers for various applications, and the advantages of the optical sensors were highlighted, particularly in microscopic applications.