Wojciech Koltunowicz

Dr. Wojciech Koltunowicz

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2023 in e+i Elektrotechnik und Informationstechnik
Verified
Journal Article
Closed access
PDF file
WKWojciech Koltunowicz
Wojciech Koltunowicz
GBGlenn Behrmann
Glenn Behrmann
MBMatthias Boltze
Matthias Boltze
ACAndrea Caprara
Andrea Caprara
GCGraeme Coapes
Graeme Coapes
TYTakanori Yasouka
Takanori Yasouka

22 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
PKPaweł Kluge
Paweł Kluge
JSJacek Starzyński
Jacek Starzyński
WKWojciech Koltunowicz
Wojciech Koltunowicz
Tomasz BednarczykTomasz Bednarczyk
Tomasz Bednarczyk
Łukasz KolimasŁukasz Kolimas
Łukasz Kolimas
Partial discharge (PD) measurements are crucial for evaluating the condition of the insulation systems of medium-voltage (MV) cables and their accessories. However, identifying PD defect types from phase-resolved partial discharge (PRPD) patterns still largely relies on expert knowledge. In this paper, the authors critically evaluate lightweight deep neural network architectures for automated classification of insulation defects from PRPD patterns: YOLOv8n, the MobileNetV2–YOLO hybrid network, and a compact SqueezeNet-based model. PD measurements were performed in a controlled environment in a factory laboratory for MV power cables in order to better evaluate the capability of the investigated models. The results demonstrate that lightweight deep neural architectures can effectively classify PRPD patterns and be deployed in a real measurement environment. The proposed approach has been integrated with the OMICRON MPD Suite measurement system, enabling automated defect recognition and visualisation during routine testing of MV cable.

3 October 2022 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
TBTomasz Bednarczyk
Tomasz Bednarczyk
WKWojciech Koltunowicz
Wojciech Koltunowicz
MKMichael Krueger
Michael Krueger
URUdo Ranninger
Udo Ranninger
W artykule przedstawiono zastosowanie trzech metod pomiaru wyładowań niezupełnych do oceny stanu izolacji transformatora energetycznego o mocy 300 MVA i napięciu 210/110/21 kV. Omówiono metodę lokalizacji miejsca uszkodzeń oraz sposób oceny rezultatów badań na podstawie wyników z pomiarów off-line jak również z monitorowania ciągłego wyładowań niezupełnych.