SELIN OZTEBER

Ms. SELIN OZTEBER


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2026 in Materials
Verified
Journal Article
Open access
PDF file
AMAli Mardani
Ali Mardani
MHMohammad Hematibahar
Mohammad Hematibahar
SOSELIN OZTEBER
SELIN OZTEBER
QQQais Abdulrahman Ali Qais
Qais Abdulrahman Ali Qais
IKIvan Khalil
Ivan Khalil
AEAhmed Elsheikh
Ahmed Elsheikh
The structural use of three-dimensional concrete printing remains limited by the directional weakness introduced during extrusion and layer-by-layer deposition. Although 3DPC offers major advantages in formwork elimination, architectural freedom, and automated construction, its printed architecture produces interfaces, pore networks, and reinforcement discontinuities that do not exist in the same form in conventionally cast concrete. This review examines the anisotropic behavior of 3DPC by linking its architectural arrangement, physical interlayer mechanisms, and chemical durability-related processes. The analysis shows that anisotropy develops from the combined effects of filament orientation, interlayer bonding quality, pore morphology, cold-joint formation, mechanical interlocking, hydration continuity, and reinforcement limitations. Weak interlayer regions act not only as preferred paths for crack initiation and propagation under tensile, flexural, shear, and compressive loading, but also as transport channels that accelerate water absorption, chloride ingress, carbonation, sulfate attack, and freeze–thaw deterioration. The review further highlights that fiber, textile, FRP, and discrete reinforcement strategies can reduce some consequences of anisotropy, but their effectiveness depends on whether they bridge the weaker interlayer regions rather than merely reinforcing the filament direction. SEM-based observations confirm that microstructural discontinuities, fiber-matrix debonding, irregular hydration products, and connected pores provide the material-level basis for the directional response of printed concrete. Overall, anisotropy should be treated as a design-critical feature of 3DPC rather than as a secondary defect. Reliable structural application requires coordinated control of mixture rheology, deposition parameters, interlayer timing, curing, toolpath design, and reinforcement layout.

29 April 2026 in Buildings
Verified
Journal Article
Open access
PDF file
Murteda ÜNVERDİMurteda ÜNVERDİ
Murteda ÜNVERDİ
SOSELIN OZTEBER
SELIN OZTEBER
AMAli Mardani
Ali Mardani
KKKemal Karakuzu
Kemal Karakuzu
SBSultan Husein Bayqra
Sultan Husein Bayqra
Developing sustainable and fire-resistant infrastructure is a critical technological, economic, and environmental challenge for modern construction stakeholders. Traditional cementitious composites experience severe microstructural degradation under extreme temperatures and their high carbon footprint exacerbates global environmental concerns. While the individual high-temperature behaviors of supplementary cementitious materials and fibers have been widely studied, the long-term synergistic mechanisms of high-volume fly ash combined with steel fibers under extreme thermal shock remain critically underinvestigated. To address this urgent need and bridge this scientific gap, hybrid mortars incorporating high-volume fly ash (FA) and steel fibers (SF) were tested under prolonged curing (150 days) and extreme heat (up to 600 °C). In terms of engineering and construction effects, the optimal CFA50-F hybrid composite delivered the highest residual compressive and flexural capacities (retaining nearly 60% of its late-age compressive strength at 32.00 MPa), preserved acoustic continuity (restricting UPV loss to 41.4%), and severely restricted high-temperature capillary permeability (limiting the water absorption increase to 49.7%) compared to traditional plain matrices. Scientifically, this superior resistance is governed by a two-step protective mechanism. High-volume FA chemically stabilizes the matrix by consuming vulnerable portlandite and preventing the formation of expansive calcium oxide. Simultaneously, ultra-fine FA particles physically densify the interfacial transition zones, securely anchoring the steel fibers and preventing premature high-temperature pull-out, while enabling the fibers to bridge thermally induced macro-cracks successfully. Environmentally and economically, an annualized service-life Life Cycle Assessment (LCA) revealed that substituting 50% of the cement with FA completely subsidizes the production-stage carbon penalty of the metallic reinforcement. By extending the operational lifespan to 40 years, the CFA50-F composite achieves a net 27% reduction in annualized global warming potential, providing a highly sustainable and cost-effective material solution.

25 July 2026 in Buildings
Verified
Journal Article
Open access
PDF file
VGVeysel Gider
Veysel Gider
SESerdar Ekinci
Serdar Ekinci
Davut IzciDavut Izci
Davut Izci
BGBurcu Bektaş Güneş
Burcu Bektaş Güneş
CBCafer Budak
Cafer Budak
AMAli Mardani
Ali Mardani
Reliable assessment of polycarboxylate ether (PCE)–binder combinations requires predictive models whose interpolation performance is distinguished from their performance when an entire formulation is absent from training. This study examined 616 cement–fly ash pastes prepared using twenty-two in-house PCE formulations, four fly ash replacement levels (0, 15, 30, and 45 wt %), seven PCE dosages (0.50–2.00 wt % of binder), and a fixed water-to-binder ratio of 0.35. Marsh funnel flow time was measured for all mixtures, whereas mini-slump measurements were available for 252 mixtures comprising nine PCE formulations. Ten regression algorithms were evaluated using 3 × 5-fold repeated cross-validation and nine non-algebraically redundant input variables. XGBoost achieved R2 = 0.946 ± 0.027 and RMSE = 8.40 s for flow time, and R2 = 0.778 ± 0.061 and RMSE = 0.471 cm for mini-slump. These random-resampling results describe interpolation among formulations represented in the training folds. When each PCE chemistry was withheld in turn, the mean R2 was 0.865 ± 0.198 for flow time and 0.034 ± 0.530 for mini-slump. Performance also decreased when the boundary fly ash levels were withheld. SHAP and permutation analyses identified PCE dose and fly ash replacement as the strongest predictors, while the formulation-level descriptors made smaller contributions. These findings represent associations learned from the present dataset and do not constitute direct evidence of adsorption or dispersion mechanisms. At a nominal 90% level, split-conformal intervals achieved empirical coverages of 85.5% for flow time—moderately below the nominal level, within finite-sample binomial fluctuation—and 90.2% for mini-slump on a random test partition; across fifty repeated train–calibration–test splits, the mean coverages were 89.4 ± 3.6% and 90.1 ± 5.8%. The flow-time model is suitable for preliminary screening within the investigated factor ranges, whereas the mini-slump model should be restricted to interpolation among the sampled formulations.

30 August 2026 in Materials
Verified
Journal Article
Open access
PDF file
AMAli Mardani
Ali Mardani
MHMohammad Hematibahar
Mohammad Hematibahar
SOSELIN OZTEBER
SELIN OZTEBER
QQQais Abdulrahman Ali Qais
Qais Abdulrahman Ali Qais
ANABBAS ABDULHUSSEIN ABD NOOR
ABBAS ABDULHUSSEIN ABD NOOR
AEAhmed Elsheikh
Ahmed Elsheikh
The structural application of 3D printed concrete (3DPC) is still constrained by the difficulty of qualifying a layered, process-dependent material using standards developed mainly for cast concrete and conventional masonry. This review examines 3DPC through masonry construction to clarify how interface-controlled behaviour should be interpreted, tested and standardised. The comparison is not based on material similarity, but on the shared structural role of joints, interfaces and assemblage-level load transfer. Most previous reviews mainly discuss printability, mixture design, material development or general mechanical performance. This review instead places the printed interface at the centre of structural qualification, using masonry only as a reference for interpreting joint-controlled load transfer. The review shows that compressive strength alone is insufficient for structural qualification, since printed elements may fail through interlayer debonding, direction-dependent cracking, filament instability, reinforcement discontinuity or connection weakness. Flexural, shear, cyclic and seismic responses are particularly sensitive to interlayer quality, loading orientation and print-path geometry. Existing concrete, mortar and masonry standards remain useful references, but require 3DPC-specific reporting and testing. Accordingly, a tiered qualification route is proposed, progressing from fresh-state characterisation to interface-dominated testing and structural-scale validation.