Miguel Lume

Dr. Miguel Lume


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2023 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
CCCatarina Castro
Catarina Castro
JMJoao Heitor Marques
Joao Heitor Marques
NSNisa Silva
Nisa Silva
AAAna Carolina Abreu
Ana Carolina Abreu
MFMaria João Furtado
Maria João Furtado
MLMiguel Lume
Miguel Lume
Purpose: To evaluate the agreement between conventional fundus photography (CFP) and multicolor fundus imaging (MFI) for the detection of lesions of diabetic retinopathy (DR) and retinal vein occlusion (RVO). Methods: Cross-sectional analysis of eyes with DR or RVO who underwent CFP and MFI. All images were independently analyzed by two observers (O1 and O2), and the evaluated lesions were classified as “present” or “absent”. Then, a paired comparison between both exams of the same eye was performed, to assess which made it easier to detect the lesions. Results: Considering DR, the agreement was substantial for cotton wool spots and photocoagulation scars for both observers (O1: κ=0.75 and κ=0.67; O2: κ=0.71 and κ=0.64, respectively) and for hard exudates for O1 (κ=0.80). These lesions were detected more frequently on MFI. Regarding RVO, the agreement was considered substantial for venous sheathing by O1 (κ=0.64) and moderate for optociliary shunts by O2 (κ=0.60). Optociliary shunts were detected more frequently in CPF by both observers and venous sheathing on MFI by O1. For microaneurysms, retinal hemorrhages, retinal neovascularization, and proliferative membranes, in DR, and retinal hemorrhages, venous engorgement, and retinal neovascularization in RVO, the agreement was almost perfect (κ> 0.82). In the paired analysis, both observers considered that, in DR, microaneurysms and retinal hemorrhages were easier to detect on CFP and that retinal neovascularization, cotton wool spots, and photocoagulation scars were easier to identify on MFI. Regarding RVO, optocilliary shunts were easier to identify on CFP and venous engorgement on MFI. Conclusion: The agreement of MFI and CFP was substantial to almost perfect for most lesions. MFI seems better to detect cotton wool spots and photocoagulations scars in DR and venous sheathing in RVO. Optocilliary shunts seem easier to detect on CFP.

1 January 2016 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
CVCarolina Vale
Carolina Vale
CMCarlos Menezes
Carlos Menezes
JFJ. Firmino-Machado
J. Firmino-Machado
PRPedro Rodrigues
Pedro Rodrigues
PTPaula Tenedório
Paula Tenedório
MLMiguel Lume
Miguel Lume
Purpose: The purpose of this study was to evaluate the visual and refractive outcomes and rotational stability of the new aspheric Precizon® toric intraocular lens (IOL) for the correction of corneal astigmatism in cataract surgery. Setting: Department of Ophthalmology, Hospital Geral de Santo António – Centro Hospitalar do Porto, EPE and Hospital de Pedro Hispano, Matosinhos, Portugal. Design: This was a prospective clinical study. Patients and methods: A total of 40 eyes of 27 patients with corneal astigmatism greater than 1.0 diopter (D) underwent cataract surgery with implantation of Precizon® toric IOL. IOL power calculation was performed using optical coherence biometry (IOLMaster®). Outcomes of uncorrected (UDVA) and best-spectacle corrected distance visual acuities (BCDVA), refraction, and IOL rotation were analyzed at the 1st week, 1st, 3rd, and 6th month’s evaluations. Results: The median postoperative UDVA was better than preoperative best-spectacle corrected distance visual acuity (0.02 [0.06] logMAR vs 0.19 [0.20] logMAR, P<0.001). At 6 months, postoperative UDVA was 0.1 logMAR or better in 95% of the eyes. At last follow-up, the mean spherical equivalent was reduced from -3.35±3.10 D to -0.02±0.30 D (P<0.001) with 97.5% of the eyes within ±0.50 D of emmetropia. The mean preoperative keratometric cylinder was 2.34±0.95 D and the mean postoperative refractive cylinder was 0.24±0.27 D (P<0.001). The mean IOL rotation was 2.43°±1.55°. None of the IOLs required realignment. Conclusion: Precizon® toric IOL revealed very good rotational stability and performance regarding predictability, efficacy, and safety in the correction of preexisting regular corneal astigmatism associated with cataract surgery.

8 March 2023 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
AFAndré Ferreira
André Ferreira
RARita Serrano Anjos
Rita Serrano Anjos
RJRafael José-Vieira
Rafael José-Vieira
MAMiguel Afonso
Miguel Afonso
AAAna Carolina Abreu
Ana Carolina Abreu
MLMiguel Lume
Miguel Lume

18 December 2024 in International Journal of Retina and Vitreous
Verified
Journal Article
Open access
PDF file
AFAndré Ferreira
André Ferreira
LVLuísa Viveiros
Luísa Viveiros
RFRaquel Faria
Raquel Faria
FBFrancisca Bragança
Francisca Bragança
AAAna Carolina Abreu
Ana Carolina Abreu
JAJose Paulo Andrade
Jose Paulo Andrade
Purpose: To assess the retinal microvasculature of Systemic Lupus Erythematosus (SLE) patients using Optical Coherence Tomography Angiography (OCTA). Methods: Twenty adult SLE patients without disease activity and no ocular manifestations were recruited and cross-sectionally assessed. A demographically similar cohort of healthy subjects was used for comparison. The main outcome is vascular density (VD). As secondary outcomes, foveal avascular zone (FAZ) parameters, total vessel length (TVL), vessel length density (VLD), vessel diameter and tortuosity, branchpoint density (BD) and fractal dimension (FD) were evaluated. Results: Forty eyes of 40 women (20 SLE patients and 20 healthy subjects) were enrolled with a mean ± SD age of 36.7 ± 9.9 years. In both the superficial and deep capillary plexuses, SLE patients presented significantly lower VD and TVL values, mean vessel diameter and FD (all p < 0.005). No significant differences were found in FAZ values. A negative correlation was found between age and FAZ parameters and between age and TVL, VLD and FD in the superficial capillary plexus (all p < 0.05). Conclusions: This study supports the evidence of subclinical retinal microvascular changes in adult SLE patients, providing a more comprehensive characterization of vascular changes. We found vessel diameter and length and FD are decreased in SLE. Trial registration: NCT05863689, 2023-10-19.

14 December 2022 in Ophthalmologica
Verified
Journal Article
Closed access
PDF file
JLJoão Leite
João Leite
CCCatarina Castro
Catarina Castro
AAAna Carolina Abreu
Ana Carolina Abreu
BPBernardete Pessoa
Bernardete Pessoa
MFMaria João Furtado
Maria João Furtado
PMPedro Menéres
Pedro Menéres
Introduction: Intravitreal injections (IVIs) are currently the most common intraocular surgical procedure worldwide. Some studies have reported a higher risk of intraoperative complications, namely, posterior capsular rupture (PCR), during cataract surgery. The aim of this retrospective and observational study, conducted at Department of Ophthalmology, Centro Hospitalar Universitário do Porto, was to assess the risk of PCR during cataract surgery in eyes previously treated with IVIs with anti-vascular endothelial growth factor (anti-VEGF) and/or corticosteroids. Methods: Eyes undergoing cataract surgery between June 2019 and May 2021 were included. Combined surgeries, such as glaucoma surgery and pars plana vitrectomy, were excluded. The occurrence of PCR during cataract surgery in treated and previously untreated eyes with IVI was analyzed. Results: A total of 5,813 cataract surgeries were analyzed; 4.1% of the cases had previously undergone IVI. The PCR rate in cataract surgery was 1.8%: 6.7% in eyes previously treated with IVI and 1.6% without previous IVI (OR = 4.5, 95% CI: 2.6–7.7, p < 0.001). The combined therapy (anti-VEGF with corticosteroids) presents a higher risk compared to the two therapies alone as monotherapy (OR = 11.6, 95% CI: 4.7–28.5, p < 0.001), as well as treated eyes treated with ≥10 IVI (OR = 2.1, 95% CI: 0.8–6.1, p = 0.144) and a time interval between the last IVI and cataract surgery was ≤6 months (OR = 1.9, 95% CI: 0.6–6.1, p = 0.296). Conclusion: These results demonstrate that eyes that require IV treatment prior to cataract surgery are at increased risk of CPA during cataract surgery, and careful assessment of the characteristics of the cataract and posterior capsule is critical.

1 December 2020 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
PBPedro Baptista
Pedro Baptista
SMSílvia Monteiro
Sílvia Monteiro
AAAna Carolina Abreu
Ana Carolina Abreu
JPJoão Poças
João Poças
DJDiana José
Diana José
MPMaria Do Céu Pinto
Maria Do Céu Pinto
Purpose: To analyze and compare the mid-term objective and subjective performance of two phakic intraocular lenses (PIOLs) – Visian® ICL™ V4c and Artiflex® and to correlate those results with anatomical parameters. Patients and Methods: Observational retrospective study including thirty patients (15 for each PIOL) randomly selected from those who underwent bilateral implantation of one of the PIOLs (60 eyes were analysed). Uncorrected and corrected distance visual acuities (UDVA and CDVA), anterior chamber structural parameters, and corneal endothelial cells density and morphology were evaluated. Quality of vision was assessed both subjectively with a questionnaire, and objectively using a double-pass technology optical quality analysis system. Results: At the end of follow-up the Artiflex® group showed better UDVA (0.95± 0.11 vs 0.99± 0.05, p=0.027) and higher proportion of eyes reaching at least 20/20 (28/30 vs 18/30, p=0.005). Excellent and similar objective scatter index (1.79± 0.9 vs 2.14± 1.6, p=0.306) and modular transfer function cutoff frequency (26.91± 9.2 vs 26.51± 11.9, p=0.784) results were achieved in the HD Analyzer® and the questionnaire showed comparable high Satisfaction (55.7± 3.5 vs 54.3± 5.4, p=0.386) and low Dysphotopsia Scores (3.1± 1.8 vs 2.1± 2.2, p=0.213). The ICL group showed inferior anterior chamber volume (p< 0.001), and angle (p< 0.001) and superior pupillary diameter (p=0.007). Minimum follow-up was 24 months. Conclusion: Both the Visian® ICLV4c™ and the Artiflex® showed excellent optical performance through the HD AnalyzerTM technology, translated in high patient satisfaction. Overall, both PIOLs showed similar safety, predictability, stability and effectiveness of for the reduction of high sphero-cylindrical refractive errors, despite better UDVA results with the Artiflex®.