Stéphane Bedwani

Dr. Stéphane Bedwani

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2008 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SBStéphane Bedwani
Stéphane Bedwani
DWDaniel Wegner
Daniel Wegner
Michael F. CrommieMichael F. Crommie
Michael F. Crommie
ARAlain Rochefort
Alain Rochefort
The interaction of the strong electron-acceptor tetracyanoethylene with the Cu(100) surface is studied with scanning tunneling microscopy experiments and first-principles density functional theory calculations. We compare two different adsorption models with the experimental results and show that the molecular self-assembly is caused by a strong structural modification of the Cu(100) surface rather than the formation of a coordination network by diffusing Cu adatoms. Surface atoms become highly buckled, and the chemisorption of tetracyanoethylene is accompanied by a partial charge transfer.

28 September 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
ALAndréanne Lapointe
Andréanne Lapointe
HBHouda Bahig
Houda Bahig
DBDanis Blais
Danis Blais
HBHugo Bouchard
Hugo Bouchard
ÉFÉdith Filion
Édith Filion
SBStéphane Bedwani
Stéphane Bedwani

2 September 2021 in Viruses
Verified
Journal Article
Open access
PDF file
Simon Grandjean LapierreSimon Grandjean Lapierre
Simon Grandjean Lapierre
SBStéphane Bedwani
Stéphane Bedwani
FDFrançois DeBlois
François DeBlois
AFAudray Fortin
Audray Fortin
NZNatalia Zamorano
Natalia Zamorano
NGNathalie Grandvaux
Nathalie Grandvaux
3D-printed alternatives to standard flocked swabs were rapidly developed to provide a response to the unprecedented and sudden need for an exponentially growing amount of diagnostic tools to fight the COVID-19 pandemic. In light of the anticipated shortage, a hospital-based 3D-printing platform was implemented in our institution for the production of swabs for nasopharyngeal and oropharyngeal sampling based on the freely available, open-source design provided to the community by University of South Florida’s Health Radiology and Northwell Health System teams as a replacement for locally used commercial swabs. Validation of our 3D-printed swabs was performed with a head-to-head diagnostic accuracy study of the 3D-printed “Northwell model” with the cobas PCR Media® swab sample kit. We observed an excellent concordance (total agreement 96.8%, Kappa 0.936) in results obtained with the 3D-printed and flocked swabs, indicating that the in-house 3D-printed swab could be used reliably in the context of a shortage of flocked swabs. To our knowledge, this is the first study to report on autonomous hospital-based production and clinical validation of 3D-printed swabs.

12 March 2020 in Cureus
Verified
Journal Article
Open access
PDF file
DMDominique Mathieu
Dominique Mathieu
SBStéphane Bedwani
Stéphane Bedwani
JMJulia Mascolo-Fortin
Julia Mascolo-Fortin
NCNicolas Côté
Nicolas Côté
ABAndrée-Anne Bernard
Andrée-Anne Bernard
TVToni Vu
Toni Vu
To compare cardiac doses of different whole-breast optimization schemes including free-breathing (FB) tangential radiotherapy (TRT), deep-inspiration breath-hold (DIBH) TRT, and FB helical tomotherapy (HT). Early-stage left-sided breast cancer patients who underwent breast-conserving surgery followed by adjuvant radiotherapy were included in the study. Planning images included FB and DIBH CT scans acquired in the same supine treatment position with both arms abducted. A hypofractionated regimen of 42.5 Gy in 16 fractions was used. Clinical target volume delineation was aided through the use of a radio-opaque wire. A 7-mm margin was used in generating the planning target volumes. TRT plans were generated both in FB and DIBH. For the FB tomotherapy technique, a first plan (Tomo 1) was optimized limiting the maximum contralateral breast dose to 3.1 Gy. A second tomotherapy plan (Tomo 2) focused on the reduction of the mean heart dose without controlling the contralateral breast dose. All plans were optimized to obtain an equivalent planning target volume (PTV) coverage of ≥95% of the prescribed dose while minimizing the dose to organs at risk. Twenty-three patients treated between October 2012 and March 2016 were included in this retrospective study. Eleven patients (48%) had at least one major cardiovascular risk factors including one patient (4%) with a history of myocardial infarction. Six patients (26%) had been exposed to cardiotoxic chemotherapy agents. The average mean dose to the heart was 3.1 Gy with FB TRT, 1.1 with DIBH TRT, 2.4 Gy for Tomo 1, and 1.5 Gy for Tomo 2. The mean dose to the left anterior descending artery was 27.0 Gy, 8.0 Gy, 13.7 Gy and 6.6 Gy for FB TRT, DIBH TRT, Tomo 1 and Tomo 2 plans respectively. Different cardiac-sparing optimization schemes are possible when treating left breast cancer. Although DIBH offers clear mean heart dose reductions, tomotherapy can be an interesting alternative treatment modality to spare the heart and coronary vessels, notably in patients who cannot comply with DIBH.

29 September 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
SBStéphane Bedwani
Stéphane Bedwani
DBDanis Blais
Danis Blais
DRDavid Roberge
David Roberge
FDFrançois DeBlois
François DeBlois
Purpose: The geometry of an immobilization device such as a headrest can cause undesired computed tomography (CT) artifacts that may affect both volume definition and dosimetry in radiotherapy of the brain. The purpose of this work was to reduce CT artifacts caused by a standard hard plastic hollow radiotherapy headrest. This was to be achieved through design and prototyping of a custom‐made head support.Methods: A series of CT scans were acquired of both a water phantom and an anthropomorphic head phantom which were resting on custom‐made three‐dimensional (3D) printed supports. All custom‐made supports were made of polylactic acid (PLA) plastic filament and printed by fused deposition modeling (FDM) 3D printing technology. Initial designs were studied with a water phantom using a simplified support with straight and curved shapes both at the edges and as infill patterns. Imaging of a 3D printed clinical prototype was then compared to our standard headrest using an anthropomorphic head phantom.Results: The presence of dark streaks inside both phantoms was seen on the CT images for headrests involving supports with straight shapes at the edges or as infill patterns. Such artifacts were ascribed to the exponential edge‐gradient effect (EEGE). No such artifact was observed when the support was designed with a combination of curved edges and infill patterns.Conclusion: When developing immobilization accessories for use in CT scanners, more attention could be paid to artifact attenuating design elements. This work illustrates the usefulness of 3D printing in prototyping radiotherapy accessories and solving concrete clinical problems.

1 March 2018 in Brachytherapy
Verified
Journal Article
Closed access
DTDaniel Taussky
Daniel Taussky
SBStéphane Bedwani
Stéphane Bedwani
NMNissan Meissner
Nissan Meissner
JBJean-Paul Bahary
Jean-Paul Bahary
CLCarole Lambert
Carole Lambert
GDGuila Delouya
Guila Delouya