Background: The Rapid Upper Limb Assessment (RULA) is used for the risk assessment of workplace-related activities. Thus far, the paper and pen method (RULA-PP) has been predominantly used for this purpose. In the present study, this method was compared with an RULA evaluation based on kinematic data using inertial measurement units (RULA-IMU). The aim of this study was, on the one hand, to work out the differences between these two measurement methods and, on the other, to make recommendations for the future use of the respective method on the basis of the available findings. Methods: For this purpose, 130 (dentists + dental assistants, paired as teams) subjects from the dental profession were photographed in an initial situation of dental treatment and simultaneously recorded with the IMU system (Xsens). In order to compare both methods statistically, the median value of the difference of both methods, the weighted Cohen’s Kappa, and the agreement chart (mosaic plot) were applied. Results: In Arm and Wrist Analysis—area A—here were differences in risk scores; here, the median difference was 1, and the agreement in the weighted Cohen’s kappa test also remained between 0.07 and 0.16 (no agreement to poor agreement). In area B—Neck, Trunk, and Leg Analysis—the median difference was 0, with at least one poor agreement in the Cohen’s Kappa test of 0.23–0.39. The final score has a median of 0 and a Cohen’s Kappa value of 0.21–0.28. In the mosaic plot, it can be seen that RULA-IMU had a higher discriminatory power overall and more often reached a value of 7 than RULA-PP. Conclusion: The results indicate a systematic difference between the methods. Thus, in the RULA risk assessment, RULA-IMU is mostly one assessment point above RULA-PP. Therefore, future study results of RULA by RULA-IMU can be compared with literature results obtained by RULA-PP to further improve the risk assessment of musculoskeletal diseases.
Purpose: To evaluate the diagnostic performance of a dual-energy computed tomography (DECT)-based material decomposition algorithm for iodine quantification and fat fraction analysis to detect lymph node metastases in breast cancer patients. Materials and Methods: 30 female patients (mean age, 63.12 ± 14.2 years) diagnosed with breast cancer who underwent pre-operative chest DECT were included. To establish a reference standard, the study correlated histologic repots after lymphadenectomy or confirming metastasis in previous/follow-up examinations. Iodine concentration and fat fraction were determined through region-of-interest measurements on venous DECT iodine maps. Receiver operating characteristic curve analysis was conducted to identify the optimal threshold for differentiating between metastatic and non-metastatic lymph nodes. Results: A total of 168 lymph nodes were evaluated, divided into axillary (metastatic: 46, normal: 101) and intramammary (metastatic: 10, normal: 11). DECT-based fat fraction values exhibited significant differences between metastatic (9.56 ± 6.20%) and non-metastatic lymph nodes (41.52 ± 19.97%) (p < 0.0001). Absolute iodine concentrations showed no significant differences (2.25 ± 0.97 mg/mL vs. 2.08 ± 0.97 mg/mL) (p = 0.7999). The optimal fat fraction threshold for diagnosing metastatic lymph nodes was determined to be 17.75%, offering a sensitivity of 98% and a specificity of 94%. Conclusions: DECT fat fraction analysis emerges as a promising method for identifying metastatic lymph nodes, overcoming the morpho-volumetric limitations of conventional CT regarding lymph node assessment. This innovative approach holds potential for improving pre-operative lymph node evaluation in breast cancer patients, offering enhanced diagnostic accuracy.
1 October 2021 in International Journal of Infectious Diseases
Objectives To prospectively evaluate lung ultrasound in comparison with radiography and computed tomography (CT) for detecting HIV-related lung diseases. Methods Ultrasound examinations in HIV-positive patients were evaluated by three raters; available conventional imaging was evaluated by another rater. Results were compared with each other and the definite diagnosis. Interrater reliability was calculated for each finding. Results Eighty HIV-positive patients received lung ultrasound examinations; 74 received conventional imaging. The overall sensitivity was 97.5% for CT, 90.7% for ultrasound and 78.1% for radiography. The most common diagnoses were Pneumocystis jirovecii pneumonia (21 cases) and bacterial pneumonia (17 cases). The most frequent and sensitive ultrasonographic findings were interstitial abnormalities indicated by B-lines, independent of the aetiology. Interrater reliability was high for interstitial abnormalities (ICC=0.82). The interrater reliability for consolidations and effusion increased during the study (r=0.88 and r=0.37, respectively). Conclusions Ultrasound is a fast, reliable and sensitive point-of-care tool, particularly in detecting interstitial lung disease, which is common in HIV-associated illness. It does not effectively discriminate between different aetiologies. A longer learning period might be required to reliably identify consolidations and effusions.
Summary: Background: Whether current real-world treatment of critical limb ischemia with lower extremity bypass (LEB) or infrainguinal endovascular intervention (IEI) meets the Society for Vascular Surgery objective performance goals (OPG) was investigated. Materials and methods: Literature search in PubMed, studies from 2010 to March 2021. A total of 35,981 endovascular interventions were reported in 82 publications and 26,707 open procedures in 49 publications. Results: Perioperative major adverse limb events was 8% (OPG) versus 9% for IEI and 10% for LEB (no significant differences). Perioperative major adverse cardiovascular events was significantly better with IEI (4%; p < .001) and LEB (6%; p = .018) than the OPG (8%). After 1 year, amputation-free survival (AFS) was 76.5% (OPG), compared to 71% with IEI (p = .932) and 77% with LEB (p = .006) and patient survival was 85.7% (OPG) compared to 84% (LEB; p = .006) and 78% (IEI; p = .102). 5-year survival was 51% with LEB and 45% with IEI (p = .320), and AFS was 44% with LEB and 46% with IEI (p = .802). 5-year OPGs were not reported. Conclusions: In the studies analysed, the results after IEI and LEB largely corresponded to the OPGs. 5-year outcomes after LEB and IEI did not differ significantly.
Background:Magnetic resonance imaging (MRI) provides higher diagnostic sensitivity than computed tomography (CT) for detecting subtle brain pathology in critically ill patients. However, MRI is resource-intensive and associated with risks during intrahospital transport. Whether MRI performed after an inconclusive CT meaningfully influences clinical management in intensive care unit (ICU) patients remains uncertain. This study evaluated the clinical impact of additional brain MRI and explored whether simple clinical variables could identify patients most likely to benefit. Methods:We conducted a retrospective single-center cohort study of adult ICU patients undergoing brain MRI after an inconclusive CT between 2007 and 2022. The primary outcome was clinical benefit, defined as an MRI-driven change in diagnosis, therapy, level of care, or prognosis. Secondary analyses compared CT accuracy between general radiologists and neuroradiologists and assessed a decision-tree model for predicting MRI benefit. Results:A total of 347 patients were included. MRI was classified as clinically beneficial in 42.9% of cases, although changes in therapy and level of care occurred in only 16.4% and 6.6% of patients, respectively. The decision-tree model achieved a sensitivity of 80% but showed limited overall performance (accuracy 55%, precision 49%, F1-score 61%). Neuroradiologists demonstrated higher CT diagnostic accuracy than general radiologists (56.8% vs 42.7%; p<0.001). Only one transport-related complication occurred. Conclusions:Although MRI frequently detects additional abnormalities after inconclusive CT, its impact on immediate clinical management in ICU patients is limited. Simple predictive modelling was insufficient to guide patient selection. Portable MRI systems may represent a safer and more resource-efficient alternative