This article describes the technical principles and clinical applications of dual-energy computed tomography (DECT) in the context of cardiothoracic imaging with a focus on current developments and techniques. Since the introduction of DECT, different vendors developed distinct hard and software approaches for generating multi-energy datasets and multiple DECT applications that were developed and clinically investigated for different fields of interest. Benefits for various clinical settings, such as oncology, trauma and emergency radiology, as well as musculoskeletal and cardiovascular imaging, were recently reported in the literature. State-of-the-art applications, such as virtual monoenergetic imaging (VMI), material decomposition, perfused blood volume imaging, virtual non-contrast imaging (VNC), plaque removal, and virtual non-calcium (VNCa) imaging, can significantly improve cardiothoracic CT image workflows and have a high potential for improvement of diagnostic accuracy and patient safety.
Background: To evaluate if coronary CT angiography (CCTA) monoenergetic reconstructions, obtained with a dual-layer spectral detector computed tomography (DLCT) system, offer improved image quality compared with 120 kVp conventional images without affecting the quantitative assessment of coronary stenoses. Methods: Fifty CCTA datasets (30 men; mean age: 61.6 ± 12.3 years) acquired with a DLCT system were reconstructed using virtual monoenergetic images (VMI) from 40 to 100 keV with 10 keV increment and compared with conventional images. An analysis of objective image quality was performed, evaluating the signal- and contrast-to-noise ratio. For the subjective assessment, two readers used a 5-point Likert scoring system to evaluate sharpness, noise, demarcation of coronary plaques, vascular contrast, and an overall score. Furthermore, coronary stenoses were analyzed for each vessel to describe the diagnostic agreement between monoenergetic images and conventional images. Results: The objective image analysis showed that all reconstructions from 70 keV to 40 keV show higher SNR (from 61.33 ± 12.46 to 154.22 ± 42.91, respectively) and CNR (from 51.45 ± 11.19 to 135.63 ± 39.38, respectively) compared with conventional images (all p < 0.001). The 40 keV monoenergetic images obtained the best average score for sharpness, vascular contrast, and for the overall impression (all with p < 0.001). The detection and grading of stenoses of the coronary arteries with conventional and monoenergetic images at 70 keV and 40 keV showed an overall excellent interobserver agreement (k= 0.81 [0.72–0.91]). Conclusions: The 40 keV virtual monoenergetic images obtained with a DLCT system allow the objective and subjective image quality of coronary CT angiography to be improved.
Purpose: To investigate the diagnostic performance of noise-optimized virtual monoenergetic images (VMI+) in dual-energy CT (DECT) of portal vein thrombosis (PVT) compared to standard reconstructions. Method: This retrospective, single-center study included 107 patients (68 men; mean age, 60.1 ± 10.7 years) with malignant or cirrhotic liver disease and suspected PVT who had undergone contrast-enhanced portal-phase DECT of the abdomen. Linearly blended (M_0.6) and virtual monoenergetic images were calculated using both standard VMI and noise-optimized VMI+ algorithms in 20 keV increments from 40 to 100 keV. Quantitative measurements were performed in the portal vein for objective contrast-to-noise ratio (CNR) calculation. The image series showing the greatest CNR were further assessed for subjective image quality and diagnostic accuracy of PVT detection by two blinded radiologists. Results: PVT was present in 38 subjects. VMI+ reconstructions at 40 keV revealed the best objective image quality (CNR, 9.6 ± 4.3) compared to all other image reconstructions (p < 0.01). In the standard VMI series, CNR peaked at 60 keV (CNR, 4.7 ± 2.1). Qualitative image parameters showed the highest image quality rating scores for the 60 keV VMI+ series (median, 4) (p ≤ 0.03). The greatest diagnostic accuracy for the diagnosis of PVT was found for the 40 keV VMI+ series (sensitivity, 96%; specificity, 96%) compared to M_0.6 images (sensitivity, 87%; specificity, 92%), 60 keV VMI (sensitivity, 87%; specificity, 97%), and 60 keV VMI+ reconstructions (sensitivity, 92%; specificity, 97%) (p ≤ 0.01). Conclusions: Low-keV VMI+ reconstructions resulted in significantly improved diagnostic performance for the detection of PVT compared to other DECT reconstruction algorithms.
Objectives: The purpose of this study was to evaluate the diagnostic accuracy of third-generation dual-source dual-energy CT (DECT) color-coded collagen reconstructions for the assessment of the cruciate ligaments compared to standard grayscale image reconstruction. Methods: Patients who underwent third-generation dual-source DECT followed by either 3-T MRI or arthroscopy of the knee joint within 14 days between January 2016 and December 2021 were included in this retrospective study. Five radiologists independently evaluated conventional grayscale DECT for the presence of injury to the cruciate ligaments; after 4 weeks, readers re-evaluated the examinations using grayscale images and color-coded collagen reconstructions. A reference standard for MRI was provided by a consensus reading of two experienced readers and arthroscopy. Sensitivity and specificity were the primary metrics of diagnostic performance. Results: Eighty-five patients (mean age, 44 years ± 16; 50 male) with injury to the ACL or PCL (n = 31) were ultimately included. Color-coded collagen reconstructions significantly increased overall sensitivity (94/105 [90%] vs. 67/105 [64%]), specificity (248/320 [78%] vs. 215/320 [67%]), PPV (94/166 [57%] vs. 67/162 [39%]), NPV (248/259 [96%] vs. 215/253 [85%]), and accuracy (342/425 [81%] vs. 282/425 [66%]) for the detection of injury to the anterior cruciate ligament (all parameters, p < .001). For injury to the posterior cruciate ligament, diagnostic accuracy increased for complete tears (p < .001). Color-coded collagen reconstructions achieved superior diagnostic confidence, image quality, and noise scores compared to grayscale CT (all parameters, p < .001) and showed good agreement with MRI examinations. Conclusions: DECT-derived color-coded collagen reconstructions yield substantially higher diagnostic accuracy and confidence for assessing the integrity of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. Key Points: • Color-coded collagen reconstructions derived from dual-energy CT yield substantially higher diagnostic accuracy and confidence for the assessment of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. • Color-coded collagen reconstructions demonstrate good agreement with MRI for the assessment cruciate ligament injury. • Dual-energy CT may serve as a readily available screening approach for patients with acute trauma to the knee when injury to the cruciate ligaments is suspected.