Eleftherios Koufakis

Dr. Eleftherios Koufakis


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2024 in Tourism and Hospitality
Verified
Journal Article
Open access
PDF file
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
DCDimosthenis Chochlakis
Dimosthenis Chochlakis
EKEleftherios Koufakis
Eleftherios Koufakis
VILELMINE CARAYANNIVILELMINE CARAYANNI
VILELMINE CARAYANNI
APAnna Psaroulaki
Anna Psaroulaki
The recreational waters of hotels are widely used by locals and travelers all around the world, and this impacts public health. In this regard, the WHO frequently offers recommendations—especially during the COVID-19 era—that operators and managers of public pools, hot tubs, or splash pads should continue to follow. This study aims to evaluate the microbiological results of COVID-19 sanitation protocols in recreational waters in hotels during the summer periods post-COVID-19 (2020–2022) and compare them with those pre-COVID-19 (2019). Of the samples tested during the pre-pandemic period, less than 1/5 were positive for total coliforms, common aerobic bacteria, and P. aeruginosa, while less than 3% of the samples tested were positive for E. coli. During the pandemic years, the percentages dropped by half for total coliforms, common aerobic bacteria, and E. coli, while only the percentage for P. aeruginosa remained the same. The relative risk (RR) for the presence of P. aeruginosa in recreational waters was greatly affected by chlorine levels, pH values, and water temperature. Our results elucidate the impact of sanitation protocols on the safety of recreational waters in hotels during public health crises. Moreover, the challenges operators face in maintaining long-term implementation of these protocols are highlighted, which in turn dictates the appropriate choice of preventive and applicable measures to ensure health and safety.

19 July 2025 in Water
Verified
Journal Article
Open access
PDF file
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
EKEleftherios Koufakis
Eleftherios Koufakis
Elias ChaidoutisElias Chaidoutis
Elias Chaidoutis
DCDimosthenis Chochlakis
Dimosthenis Chochlakis
APAnna Psaroulaki
Anna Psaroulaki
The colonization of Legionella spp. in engineered water systems constitutes a major public health threat. In this study, a six-year environmental surveillance (2020–2025) of Legionella colonization in five different types of facilities in Crete, Greece is presented, including hotels, passenger ships, primary healthcare facilities, public hospitals, and private clinics. A total of 1081 water samples were collected and analyzed, and the overall positivity was calculated using culture-based methods. Only 16.46% of the samples exceeded the regulatory limit (>103 CFU/L) in the total sample, with 44.59% overall Legionella positivity. Colonization by facility category showed the highest rates in primary healthcare facilities with 85.96%, followed by public hospitals (46.36%), passenger ships with 36.93%, hotels with 38.08%, and finally private clinics (21.42%). The association of environmental risk factors with Legionella positivity revealed a strong effect at hot water temperatures < 50 °C (RR = 2.05) and free chlorine residuals < 0.2 mg/L (RR = 2.22) (p < 0.0001). Serotyping analysis revealed the overall dominance of Serogroups 2–15 of L. pneumophila; nevertheless, Serogroup 1 was particularly prevalent in hospitals, passenger ships, and hotels. Based on these findings, the requirement for continuous environmental monitoring and risk management plans with preventive thermochemical controls tailored to each facility is highlighted. Finally, operational disruptions, such as those experienced during the COVID-19 pandemic, especially in primary care facilities and marine systems, require special attention.

20 October 2025 in Pathogens
Verified
Journal Article
Open access
PDF file
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
EKEleftherios Koufakis
Eleftherios Koufakis
VNVasileios Nakoulas
Vasileios Nakoulas
LKLeonidas Kourentis
Leonidas Kourentis
TMTheodoros Manouras
Theodoros Manouras
APAnna Psaroulaki
Anna Psaroulaki
Between April and May 2025, an outbreak of travel-associated Legionnaires’ disease (TALD) occurred, involving six cases at a hotel in Crete, Greece. Including two cases reported in 2023 and two additional cases from 2016 to 2017, ten cases were associated with this accommodation site. All TALD cases were reported by the European Legionnaires’ Disease Surveillance Network (ELDSNet). In compliance with the European Centre for Disease Prevention and Control (ECDC) surveillance and investigation protocols for hotels associated with the patient’s stay, local public health authorities conducted on-site inspections at the hotel by collecting water samples and performing risk assessments, while simultaneously recording the required epidemiological, environmental, and physicochemical data. A total of 181 statistically analyzed water samples showed positive rates for L. pneumophila of 12.71% (95% CI: 7.86–17.56) for (≥50 CFU/L) and 6.08% (95% CI: 2.60–9.56) for (≥1000 CFU/L). Risk assessments identified 18 stagnation points, systemic maintenance deficiencies, and high cumulative structural (30/52) and water (36/71) system risk scores. Low microbiological positivity of water samples does not necessarily equate to low risk, thus necessitating continuous risk assessment, implementation of Water Safety Plans (WSPs), and integrated monitoring by accommodation facilities to prevent LD cases.

26 February 2026 in Microorganisms
Verified
Journal Article
Open access
PDF file
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
EKEleftherios Koufakis
Eleftherios Koufakis
NRNikolaos Raptakis
Nikolaos Raptakis
GPGeorge Pitsoulis
George Pitsoulis
AKApostolos Kamekis
Apostolos Kamekis
Areti LagiouAreti Lagiou
Areti Lagiou
Travel-associated Legionnaires’ disease (TALD) events can generate public concern when environmental surveillance findings are communicated without an adequate explanation of the results. This study examined how surveillance data on Legionella spp. were framed and amplified during a TALD-related investigation in Crete, Greece, from June to July 2025. A mixed infodemiology and environmental surveillance approach was applied, including the analysis of 95 online media items across nine languages, Google Trends search-interest data, and hotel water-system surveillance data from epidemiologically linked facilities. Sampling conducted in a limited number of hotels associated with TALD cases indicated that approximately 50% of the water samples exceeded the laboratory reporting limit of ≥50 CFU/L for Legionella spp., a numerically correct but context-specific finding. Numerical misframing occurred in 83.7%, 41.7%, and 18.2% of Greek, German, and English language items, respectively, with significant differences across language markets (χ2 (8) = 43.75, p < 0.0001; Cramér’s V = 0.679). Public search-interest signals were transient and geographically limited. Environmental surveillance showed no increase in Legionella pneumophila risk, with similar proportions of samples ≥50 CFU/L in the pre-/peri-infodemic (January–July 2025) and post-infodemic (August–November 2025) periods (23.11% [95% CI: 18.21–28.87] vs. 24.45% [19.34–30.41]) and similar exceedance of ≥1000 CFU/L (13.45% [9.69–18.36] vs. 14.41% [10.45–19.55]). Overall, the loss of contextual interpretation of surveillance results and conflation of laboratory reporting limits with regulatory thresholds were associated with inconsistent public risk perception, without evidence of increased environmental hazard.

17 September 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
EKEleftherios Koufakis
Eleftherios Koufakis
VNVasileios Nakoulas
Vasileios Nakoulas
LKLeonidas Kourentis
Leonidas Kourentis
TMTheodoros Manouras
Theodoros Manouras
APAnna Psaroulaki
Anna Psaroulaki
Between April and May 2025, an outbreak of travel-associated Legionnaires’ disease (TALD) occurred, involving six cases at a hotel in Crete, Greece. Including two cases reported in 2023 and two additional cases from 2016 to 2017, 10 cases were associated with this accommodation site. All TALD cases were reported by the European Legionnaires’ Disease Surveillance Network (ELDSNet). In accordance with the surveillance and investigation protocols of the European Centre for Disease Prevention and Control (ECDC), local public health authorities immediately upon notification of the cases conducted on-site inspections at the hotel via the collection of water samples and conducting risk assessments, while simultaneously recording the required epidemiological, environmental, and physicochemical data. A total of 181 statistically analyzed water samples showed positive rates for Legionella spp. 13.81% (95% CI: 9.14–19.71) (≥50 CFU/L) and 7.73% (95% CI: 4.29–12.64) (≥1000 CFU/L). Risk assessments identified 18 stagnation points, systemic maintenance deficiencies, and high cumulative structural (30/52) and water (36/71) system risk scores. Low microbiological positivity of water samples does not necessarily equate to low risk, thus necessitating continuous risk assessment, implementation of Water Safety Plans, and integrated monitoring by accommodation facilities to prevent Legionnaires’ disease cases.

2 June 2026 in Microorganisms
Verified
Journal Article
Open access
PDF file
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
EKEleftherios Koufakis
Eleftherios Koufakis
DCDimosthenis Chochlakis
Dimosthenis Chochlakis
APAnna Psaroulaki
Anna Psaroulaki
In Europe, travel-associated Legionnaires’ disease (TALD) cases require timely environmental investigations to support risk assessment, rapid control measures, and prompt reporting of investigation findings to the European Legionnaires’ Disease Surveillance Network (ELDSNet). This study evaluated TALD-related environmental investigations conducted during 2025 and early 2026 in Crete, Greece, following notifications through ELDSNet. Overall, 30 notifications corresponded to 24 unique confirmed TALD cases with illness onset in 2025 and 24 implicated hotels, with some cases involving stays in multiple hotels and Regional Units and clusters identified in some implicated hotels. The investigation framework combined microbiological, physicochemical, and operational data, focusing on delays from symptom onset, notification, sampling, and laboratory reporting. Overall, 516 environmental samples were collected, of which 503 yielded valid analytical results. Among the 503 samples analyzed, Legionella spp. were detected at ≥50 colony-forming units per liter (CFU/L) in 127 samples (25.25%). This included 123 samples positive for L. pneumophila (24.45%), of which 31 were serogroup 1 (6.16%). Concentrations exceeding the 1000 CFU/L threshold were recorded in 53 samples (10.54%). Operational indicators varied, with median values of 31.0 days for reporting delay (RD), 14.5 days from notification to first sampling (TTF), 47.5 days from symptom onset to first sampling (TDS), and 67.0 days from symptom onset to first laboratory result (OELR). The findings underscore the necessity to document response delays, enhance inspector capacity and cross-regional coordination, and integrate microbiological results with operational indicators. This integration is crucial for facilitating earlier environmental risk assessments, expediting reporting, and implementing more effective TALD public health interventions.