Lakhal Yassine

Mr. Lakhal Yassine

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2023 in Journal of Robotics and Control (JRC)
Verified
Journal Article
Open access
PDF file
FBFatima Zahra Baghli
Fatima Zahra Baghli
LYLakhal Yassine
Lakhal Yassine
YKYoussef Ait El Kadi
Youssef Ait El Kadi
In this article, a robot manipulator is controlled by the PID controller in a closed loop system with unit feedback. The difficulty of using the controller is parameter tuning, because the tuning parameters still use the trial and error method to find the PID parameter constants, namely Proportional Gain (Kp), Integral Gain (Ki) and Derivative Gain (Kd). In this case the Ant colony Optimization algorithm (ACO) is used to find the best gain parameters of the PID. The Ant algorithm is a method of combinatorial optimization, which utilizes the pattern of ants search for the shortest path from the nest to the place where the food is located, this concept is applied to tuning PID parameters by minimizing the objective function such that the robot manipulator has improved performance characteristics. This work uses the Matlab Simulink environment, First, after obtaining the system model, the ant colony algorithm is used to determine the proper coefficients 𝐾p, 𝐾i, and Kd in order to minimize the trajectory errors of the two joints of the robot manipulator. Then, the parameters will implement in the robot system. According to the results of the computer simulations, the proposed method (ACO-PID) gives a system that has a good performance compared with the classical PID.

1 January 2015 in Procedia Technology
Verified
Journal Article
Open access
FBFatima Zahra Baghli
Fatima Zahra Baghli
LBLarbi El Bakkali
Larbi El Bakkali
LYLakhal Yassine
Lakhal Yassine
The robot manipulator is a mechanical system multi-articulated, in which each articulation is driven individually by an electric actuator, it is the most robot used in industry, this system need an efficient control strategy, such as Fuzzy Logic law control, by means each articulation is controlled independently, this kind of control present a lot of inconvenient, such as error of each articulation, isn’t taken account into others.In this present work, we present a Multi-Input Multi-Output Fuzzy controller (MIMO) to ensure the articulation robot control strategy, the results obtained present satisfactory and shows clearly the efficiency of the present Fuzzy-MIMO controller

26 September 2025 in Solar Energy and Sustainable Development journal
Verified
Journal Article
Open access
PDF file
AOAchraf El Ouali
Achraf El Ouali
LYLakhal Yassine
Lakhal Yassine
MBMohamed Benchagra
Mohamed Benchagra
HCHamid Chojaa
Hamid Chojaa
MMMohamed Vall Ould Mohamed
Mohamed Vall Ould Mohamed
Mitigating nonlinearities and parameter fluctuations in high-rated wind energy systems is crucial for efficient energy conversion and grid integration. This paper presents a robust Integral Sliding Mode Control (ISMC) strategy for monitoring active and reactive power in a DFIG-based wind turbine. An artificial neural network based MPPT algorithm enhances speed control and addresses power fluctuations. The proposed ISMC ensures an optimal dynamic response to wind variations. Its performance is compared using a PI controller in Field-Oriented Control (FOC_PI) in MATLAB/Simulink on a wind system of 1.5 MW and tested under real-wind conditions. Simulation results confirm that ISMC outperforms FOC_PI in reference tracking, accuracy, dynamic behavior, and current distortion reduction.

4 April 2024
Verified
Book Chapter
Closed access
PDF file
LYLakhal Yassine
Lakhal Yassine
BZBaghli Fatima Zahra
Baghli Fatima Zahra
YKYoussef Ait El Kadi
Youssef Ait El Kadi
BMBenchagra Mohammed
Benchagra Mohammed

31 July 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MTMohamed Tahiri
Mohamed Tahiri
LYLakhal Yassine
Lakhal Yassine
SLSoulaiman Louah
Soulaiman Louah
AMAbdelaziz Mimet
Abdelaziz Mimet
The following is a detailed account of how the flexibility of a drive train affects maximum power point tracking (MPPT) for wind turbines. The study uses the National Renewable Energy Laboratory 5 MW reference turbine as a base model with Kaimal spectrum having felt waves creating turbulent winds. This study compares both rigid and flexible drive trains that undergo identical turbulence conditions (average wind speed 9.0 m/s and flight weather turbulence, 16% T.I.). The results show that the flexible unit provides an 8.95 percent area increase in mean power coefficient, (p < 0.001, Cohen’s d = 2.108) while the rigid unit produces a 4173 percent (p < 10−47, Cohen’s d = 31.8) sudden rise in power during catastrophic loss of control and produce a direct torque oscillation of over 153 MN·m RMS between the two configurations. The conclusion of this research establishes that PID Controllers that are manually tuned based on measurements taken with rigid drive trains cannot be used with flexible drivetrains. Therefore, it is necessary to either re-tune the PID Controller quickly after switching between form of drive train; and/or implement advanced control strategies to effectively manage these situations in the future. This study shows that rigid-model assumptions are fundamentally inadequate for contemporary turbine control design, which directly results in decreased energy yield. The findings necessitate a paradigm shift towards control strategies that specifically take structural dynamics into consideration in order to produce vibration-resilient MPPT for next-generation turbines.