Björn Döring

Mr. Björn Döring


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2015 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Verified
Journal Article
Closed access
MSMarco Schwerdt
Marco Schwerdt
KSKersten Schmidt
Kersten Schmidt
NRNuria Ramón
Nuria Ramón
GAGabriel Castellanos Alfonzo
Gabriel Castellanos Alfonzo
BDBjörn Döring
Björn Döring
PPPau Prats-Iraola
Pau Prats-Iraola
In the frame of the COPERNICUS program, the main objective of the Sentinel-1 mission is to ensure the continuity of C-band SAR data for global earth monitoring. Sentinel-1A is the first of two C-band satellites launched in April 2014. In addition to the commissioning of Sentinel-1A executed by the European Space Agency (ESA), an independent verification of the system calibration has been performed by DLR under an ESA contract. For this purpose, the complete calibration chain was developed and established, starting with a calibration concept, a detailed in-orbit calibration plan and the software tools for analyzing and evaluating all the measurements up to the calibration targets serving as accurate reference. Based on an efficient calibration strategy, this paper describes the different activities performed by DLR and presents the results obtained during the commissioning phase (CP) of Sentinel-1A.

1 July 2011
Verified
Conference Paper
Closed access
MSMarco Schwerdt
Marco Schwerdt
JGJaime Hueso Gonzalez
Jaime Hueso Gonzalez
MBMarkus Bachmann
Markus Bachmann
DSDirk Schrank
Dirk Schrank
BDBjörn Döring
Björn Döring
JAJohn Mohan Walter Antony
John Mohan Walter Antony
In addition to the first satellite TSX already in-flight since 2007 [1], the second satellite TDX of the TanDEM-X system could be successfully launched in 2010 [2]. The primary object of the TanDEM-X mission is to generate a highly accurate digital elevation model (DEM) with never achieved accuracy on global scale. But in addition to this DEM acquisition based on a bistatic satellite constellation, nominal TerraSAR-X operation shall be available anymore, i.e. the bistatic TanDEM X mission and the monostotic TerraSAR-X mission have to be operated in parallel with both satellites. Consequently the second satellite TDX had to achieve the same accuracy and performance as those of the first satellite TSX. Based on a short overview of the different calibration procedures the pa per discusses the calibration results achieved for the whole TanDEM-X system, successfully in-flight since June 2010.

4 December 2013 in Remote Sensing
Verified
Journal Article
Open access
PDF file
BDBjörn Döring
Björn Döring
KSKersten Schmidt
Kersten Schmidt
MJMatthias Jirousek
Matthias Jirousek
DRDaniel Rudolf
Daniel Rudolf
JRJens Reimann
Jens Reimann
MSMarco Schwerdt
Marco Schwerdt
A synthetic aperture radar (SAR) system requires external absolute calibration so that radiometric measurements can be exploited in numerous scientific and commercial applications. Besides estimating a calibration factor, metrological standards also demand the derivation of a respective calibration uncertainty. This uncertainty is currently not systematically determined. Here for the first time it is proposed to use hierarchical modeling and Bayesian statistics as a consistent method for handling and analyzing the hierarchical data typically acquired during external calibration campaigns. Through the use of Markov chain Monte Carlo simulations, a joint posterior probability can be conveniently derived from measurement data despite the necessary grouping of data samples. The applicability of the method is demonstrated through a case study: The radar reflectivity of DLR’s new C-band Kalibri transponder is derived through a series of RADARSAT-2 acquisitions and a comparison with reference point targets (corner reflectors). The systematic derivation of calibration uncertainties is seen as an important step toward traceable radiometric calibration of synthetic aperture radars.

1 January 2014 in Progress In Electromagnetics Research B
Verified
Journal Article
Open access
PDF file
BDBjörn Döring
Björn Döring
JRJens Reimann
Jens Reimann
SRSebastian Raab
Sebastian Raab
MJMatthias Jirousek
Matthias Jirousek
DRDaniel Rudolf
Daniel Rudolf
MSMarco Schwerdt
Marco Schwerdt
Transponders (also known as polarimetric active radar calibrators or PARCs) are commonly used for radiometric calibration of synthetic aperture radars (SARs). Currently three methods for the determination of a transponder's frequency-dependent radar cross section (RCS) are used in practice. These require either to measure disassembled transponder components, or a separate radiometric measurement standard (like a flat, metallic plate or a corner reflector), leading to additional uncertainty contributions for the calibration result. In this paper, a novel method is introduced which neither requires disassembly nor an additional radiometric reference. Instead, the measurement results can be directly traced back to a realization of the meter, lowering total measurement uncertainties. The method is similar in approach to the well known three-antenna method, but is based on the radar equation instead of Friis transmission formula. The suitability of the method is demonstrated by a measurement campaign for DLR's three new Kalibri C-band transponders, completed by an uncertainty analysis. The method is not universally applicable for all transponder calibrations because (a) three devices are necessary (instead of only one for the known methods), and (b) the transponders must provide certain additional features. Nevertheless, these features have become standard in modern SAR calibration transponder designs. The novel, potentially more accurate three-transponder method is thus a viable alternative for transponder RCS calibration, ultimately contributing to synthetic aperture radars with a reduced radiometric measurement uncertainty.

1 July 2014
Verified
Conference Paper
Closed access
MSM. Schwerdt
M. Schwerdt
KSKersten Schmidt
Kersten Schmidt
NRN. Tous Ramon
N. Tous Ramon
GAG. Castellanos Alfonzo
G. Castellanos Alfonzo
BDBjörn Döring
Björn Döring
PPP. Prats
P. Prats
In the frame of the GMES program, the main objective of the Sentinel-1 mission is to ensure the continuity of SAR data acquisitions in C-band for global earth monitoring. Sentinel-1A is the first of two C-band satellites launched in April 2014. In addition to the commissioning of Sentienl-1A executed by ESA, an independent verification of the system calibration is executed for the first time by an external institution. For this purpose, the complete calibration chain was developed and established by DLR, starting with an efficient calibration concept, a detailed in-orbit calibration plan, the SW-tools for analyzing and evaluating all the measurements up to the calibration targets serving as accurate reference. Based on an efficient calibration strategy, this paper describes the different activities performed by DLR and presents first results obtained from real in-orbit data. As Sentinel-1A had not achieved the reference orbit at the time of uploading the full paper, a discussion of radiometric and geometric calibration results will be presented at the conference on July 2014.

1 January 2007
Verified
Conference Paper
Closed access
MSMarco Schwerdt
Marco Schwerdt
BBBenjamin Brautigam
Benjamin Brautigam
MBMarkus Bachmann
Markus Bachmann
BDBjörn Döring
Björn Döring
As TerraSAR-X, due for launch in 2007, will be an operational scientific mission with commercial potential, product quality is of crucial importance. The success or failure of the mission essentially depends on the calibration of the TerraSAR- X system ensuring the product quality and the correct in-orbit operation of the entire SAR system. The paper describes the in- orbit calibration procedure for TerraSAR-X and dedicated activities performed during the commissioning phase. First results could not be described because TerraSAR-X was not launched up to the time of uploading the full paper.