Jiacheng Xie

Mr. Jiacheng Xie

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
JXJiacheng Xie
Jiacheng Xie
HSHua-Chieh Shao
Hua-Chieh Shao
YLYunxiang Li
Yunxiang Li
YZYou Zhang
You Zhang
Objective. Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy. Reconstructing CBCTs from limited-angle acquisitions (LA-CBCT) is highly desired for improved imaging efficiency, dose reduction, and better mechanical clearance. LA-CBCT reconstruction, however, suffers from severe under-sampling artifacts, making it a highly ill-posed inverse problem. Diffusion models can generate data/images by reversing a data-noising process through learned data distributions; and can be incorporated as a denoiser/regularizer in LA-CBCT reconstruction. In this study, we developed a diffusion model-based framework, prior frequency-guided diffusion model (PFGDM), for robust and structure-preserving LA-CBCT reconstruction. Approach. PFGDM uses a conditioned diffusion model as a regularizer for LA-CBCT reconstruction, and the condition is based on high-frequency information extracted from patient-specific prior CT scans which provides a strong anatomical prior for LA-CBCT reconstruction. Specifically, we developed two variants of PFGDM (PFGDM-A and PFGDM-B) with different conditioning schemes. PFGDM-A applies the high-frequency CT information condition until a pre-optimized iteration step, and drops it afterwards to enable both similar and differing CT/CBCT anatomies to be reconstructed. PFGDM-B, on the other hand, continuously applies the prior CT information condition in every reconstruction step, while with a decaying mechanism, to gradually phase out the reconstruction guidance from the prior CT scans. The two variants of PFGDM were tested and compared with current available LA-CBCT reconstruction solutions, via metrics including peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). Main results. PFGDM outperformed all traditional and diffusion model-based methods. The mean(s.d.) PSNR/SSIM were 27.97(3.10)/0.949(0.027), 26.63(2.79)/0.937(0.029), and 23.81(2.25)/0.896(0.036) for PFGDM-A, and 28.20(1.28)/0.954(0.011), 26.68(1.04)/0.941(0.014), and 23.72(1.19)/0.894(0.034) for PFGDM-B, based on 120°, 90°, and 30° orthogonal-view scan angles respectively. In contrast, the PSNR/SSIM was 19.61(2.47)/0.807(0.048) for 30° for DiffusionMBIR, a diffusion-based method without prior CT conditioning. Significance. PFGDM reconstructs high-quality LA-CBCTs under very-limited gantry angles, allowing faster and more flexible CBCT scans with dose reductions.

25 July 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
JXJiacheng Xie
Jiacheng Xie
HSHua-Chieh Shao
Hua-Chieh Shao
YZYou Zhang
You Zhang
Objective. Time-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection without phase sorting/binning), is highly desired for regular/irregular motion characterization, patient setup, and motion-adapted radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a Gaussian representation-based framework (PMF-STGR) for fast and accurate dynamic CBCT reconstruction. Approach. PMF-STGR comprises three major components: a dense set of 3D Gaussians to reconstruct a reference-frame CBCT for the dynamic sequence; another 3D Gaussian set to capture three-level, coarse-to-fine motion-basis-components (MBCs) to model the intra-scan motion; and a CNN-based motion encoder to solve projection-specific temporal coefficients for the MBCs. Scaled by the temporal coefficients, the learned MBCs will combine into deformation vector fields (DVFs) to deform the reference CBCT into projection-specific, time-resolved CBCTs to capture the dynamic motion. Due to the strong representation power of 3D Gaussians, PMF-STGR can reconstruct dynamic CBCTs in a ‘one-shot’ training fashion from a standard 3D CBCT scan, without using any prior anatomical/motion model. Main results. We evaluated PMF-STGR using XCAT phantom simulations and real patient full/half-fan scans. Metrics, including the image relative error (RE), structural-similarity-index-measure (SSIM), tumor center-of-mass-error (COME), and landmark localization error (LE), were used to evaluate the accuracy of solved dynamic CBCTs and motion. PMF-STGR shows clear advantages over a state-of-the-art, implicit neural representation (INR)-based approach, PMF-STINR. Compared with PMF-STINR, PMF-STGR reduces reconstruction time by ~50% while reconstructing less blurred images with comparable/better motion accuracy. For XCAT, the mean(±s.d.) RE, SSIM, and COME were 0.128(0.009), 0.990(0.002), and 0.71mm(0.40mm) for PMF-STGR, compared with 0.149(0.016), 0.944(0.006), and 0.94mm(0.18mm) for PMF-STINR. For patients, the mean(±s.d.) landmark LE was 1.40mm(0.34mm) for PMF-STGR, and 1.54mm(0.35mm) for PMF-STINR. Significance. With improved efficiency/accuracy, PMF-STGR enhances the applicability of dynamic CBCT imaging for potential clinical translation.

7 June 2025 in Knowledge-Based Systems
Verified
Journal Article
Closed access
YLYunxiang Li
Yunxiang Li
XKXianghao Kong
Xianghao Kong
JXJiacheng Xie
Jiacheng Xie
GSGreg Ver Steeg
Greg Ver Steeg
YZYou Zhang
You Zhang

25 May 2026 in Cancers
Verified
Journal Article
Open access
PDF file
HWHe C. Wang
He C. Wang
YZYao Zhao
Yao Zhao
XCXinru Chen
Xinru Chen
BMBrigid McDonald
Brigid McDonald
YLYunxiang Li
Yunxiang Li
MLMu-Han Lin
Mu-Han Lin
Advanced imaging is the cornerstone of modern radiation oncology, contributing to each phase of patient care, from diagnosis and treatment planning to delivery and follow-up. It has evolved from providing purely geometric guidance to enabling biological and dynamic precision, capturing detailed spatial and functional information about tumors and surrounding tissues. This progress has also generated vast amounts of complex data that remain largely underexplored. AI-based methods have shown promises to unlock the potential of these data, ensuring quality and standardization while extracting previously inaccessible insights. AI-driven tools can enhance accuracy, efficiency, and personalization of radiation oncology through precision diagnosis, automated segmentation, adaptive treatment planning, real-time image guidance, and predictive response assessment. In this review, we conducted a systematic bibliometric analysis of relevant literature published in the last decade and explored current advancements in AI and radiomics applications across radiation oncology. We also addressed ongoing challenges, such as data heterogeneity, model interpretability, and clinical implementation, and discussed future directions for integrating AI-powered imaging solutions into routine practice to advance precision cancer care.

22 June 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
JXJiacheng Xie
Jiacheng Xie
HSHua-Chieh Shao
Hua-Chieh Shao
YLYunxiang Li
Yunxiang Li
SYShunyu Yan
Shunyu Yan
CSChenyang Shen
Chenyang Shen
YZYou Zhang
You Zhang
Objective. Deformable liver motion tracking using a single x-ray projection enables real-time motion monitoring and treatment intervention. We introduce a conditional point cloud diffusion (PCD) model-based framework for accurate and robust liver motion tracking from arbitrarily angled single x-ray projections. Approach. We propose a conditional PCD model for liver motion tracking (PCD-Liver), which estimates volumetric liver motion by solving deformable vector fields (DVFs) of a prior liver surface point cloud, based on a single x-ray image. It is a patient-specific model of two main components: a rigid alignment model to estimate the liver’s overall shifts, and a conditional PCD model that further corrects for the liver surface’s deformation. Conditioned on the motion-encoded features extracted from a single x-ray projection by a geometry-informed feature pooling layer, the diffusion model iteratively solves detailed liver surface DVFs in a projection angle-agnostic fashion. The liver surface motion solved by PCD-Liver is subsequently fed as the boundary condition into a U-Net-based biomechanical model to infer the liver’s internal motion to localize liver tumors. A dataset of 10 liver cancer patients was used for evaluation. We used the root mean square error (RMSE) and 95-percentile Hausdorff distance (HD95) metrics to examine the liver point cloud motion estimation accuracy, and the center-of-mass error (COME) to quantify the liver tumor localization error. Main Results. The mean (±s.d.) RMSE, HD95, and COME of the prior liver or tumor before motion estimation were 8.82 mm (±3.58 mm), 10.84 mm (±4.55 mm), and 9.72 mm (±4.34 mm), respectively. After PCD-Liver’s motion estimation, the corresponding values were 3.63 mm (±1.88 mm), 4.29 mm (±1.75 mm), and 3.46 mm (±2.15 mm). Under highly noisy conditions, PCD-Liver maintained stable performance. Significance. This study presents an accurate and robust framework for liver deformable motion estimation and tumor localization for image-guided radiotherapy.

19 January 2026 in Machine Learning: Health
Verified
Journal Article
Open access
SYShunyu Yan
Shunyu Yan
JXJiacheng Xie
Jiacheng Xie
NCNa Chen
Na Chen
DNDan Nguyen
Dan Nguyen
FSFan-Chi Su
Fan-Chi Su
CSChenyang Shen
Chenyang Shen
Accurate delineation of treatment targets and organs at risk (OARs) is essential to the success of radiotherapy (RT). Although artificial intelligence (AI)–based segmentation methods have successfully automated the delineation process, a reliable and efficient quality assurance (QA) mechanism is still missing, particularly in the time-critical setting of online adaptive RT (oART). This study aims to address this unmet clinical need by introducing an AI-driven multi-organ contour QA framework with uncertainty quantification. Using MR-guided oART for prostate cancer as the testbed, we developed an automatic multi-structure QA framework by employing a carefully designed contour quality estimation (ConQuE) model. Built on a ResNet34 backbone, ConQuE processes binary segmentation masks with corresponding MR images to classify contours as ‘acceptable’ or ‘revision required’ in a slice-by-slice manner. To ensure scalability, we proposed a unified framework for multi-organ QA by embedding structure-specific code into the fully connected layers. To quantify classification uncertainty, Monte Carlo (MC) dropout was employed, enabling confidence assessment of model predictions for informative decision-making in oART. ConQuE was trained to assess the segmentation quality of prostate and six OARs, including rectum, bladder, urethra, penile bulb, cauda equina, and femoral heads. Training was performed using 249 cases for training, 31 for validation, and another 31 cases were saved for testing. With 30 MC dropout passes, ConQuE can complete QA for one image slice in ∼13.1 ms. Overall, ConQuE achieved accuracy of 93.9% on all structures with structure-specific performance consistently above 90%, demonstrating its strong capability in identifying revision required contours. Moreover, incorrect predictions were strongly correlated with high uncertainty scores, underscoring the effectiveness in improving QA reliability. The proposed AI-based framework holds the potential to automate contour QA with quantified uncertainty. It is well-suited for oART with heavy time constraints given its high accuracy, efficiency, and reliability.