Benson Yang

Dr. Benson Yang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Medical Physics
Verified
Journal Article
Closed access
PDF file
BYBenson Yang
Benson Yang
FTFred Tam
Fred Tam
BDBenjamin Davidson
Benjamin Davidson
PWPei‐Shan Wei
Pei‐Shan Wei
CHClement Hamani
Clement Hamani
SGSimon J. Graham
Simon J. Graham

18 June 2019 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
BYBenson Yang
Benson Yang
PWPei-Shan Wei
Pei-Shan Wei
CMClare E. McElcheran
Clare E. McElcheran
FTFred Tam
Fred Tam
SGSimon J. Graham
Simon J. Graham

8 June 2022 in IEEE Letters on Electromagnetic Compatibility Practice and Applications
Verified
Journal Article
Closed access
BYBenson Yang
Benson Yang
Chih-Hung ChenChih-Hung Chen
Chih-Hung Chen
SGSimon J. Graham
Simon J. Graham
Parallel radiofrequency transmission (pTx) continues to demonstrate promise in addressing magnetic resonance imaging (MRI) challenges at higher magnetic-field strengths, particularly regarding the safety of patients with implanted deep brain stimulation (DBS) devices. Radiofrequency (RF) shimming optimization methods have shown the potential of pTx to minimize DBS implant safety concerns relating to induced RF heating at 3T. This letter continues the assessment of 4-channel pTx technology and its associated “safe mode” for the DBS application. Safe mode sensitivity to patient setup mispositioning and movement is important and was studied in proof-of-concept. Phantom mispositioning can impact the electromagnetic near-field distribution and potentially affect the RF heating effects along an implanted DBS device. However, thermal simulations studying DBS patient head movements were performed and indicated minimal safety risks. These results were further validated by an MRI phantom mispositioning experiment encompassing the head motion studied in simulation. Temperature increases remained below +1°C for all tested scenarios in simulation and experiment. However, a severe pitch rotation in the experiment led to a +0.8°C increase, indicating that significant patient movement may still shift implanted DBS leads into higher risk zones. In conclusion, this letter further supports the potential of 4-channel pTx to address DBS patient safety.

19 July 2023 in Medical Physics
Verified
Journal Article
Closed access
BYBenson Yang
Benson Yang
CCChih‐Hung Chen
Chih‐Hung Chen
SGSimon J. Graham
Simon J. Graham

17 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
MAMaryam Arianpouya
Maryam Arianpouya
BYBenson Yang
Benson Yang
PTPeter Truong
Peter Truong
SGSimon J Graham
Simon J Graham
Electric dipole antennas can be designed in a variety of geometries and applied across a wide range of configurations. Appropriately designed dipole antennas can provide deep tissue penetration and low radiofrequency (RF) power deposition in magnetic resonance imaging (MRI), making them attractive for applications requiring safe and effective RF transmission in deep regions. On clinical 3 T MRI systems, however, conventional dipoles are too large in size for practical imaging of the head. Inspired by telecommunications designs, the present work adapts meandered dipoles (where the conductor is folded to shorten the antenna) with the resonance frequency controlled through trace geometry. Additionally, multi-channel configurations are considered to improve RF power transmission. A straight dipole was progressively transformed into meandered geometries and characterized using benchtop measurements and electromagnetic simulations. Analyses evaluated frequency response, near-field behavior, power-flow directionality, and distributions of local tissue heating and transmitted RF magnetic field in multi-channel arrays. A four-channel parallel-transmit (pTx) prototype was also used to show the feasibility of dipole-based head imaging at 3 T. The present work demonstrates a practical implementation of compact, low-heating dipole arrays for head MRI, with potential for extension to ultra-high-field or multinuclear imaging.

7 April 2026 in Stereotactic and Functional Neurosurgery
Verified
Journal Article
Open access
PDF file
Clement ChowClement Chow
Clement Chow
CSCAN SARICA
CAN SARICA
BYBenson Yang
Benson Yang
BSBrendan Santyr
Brendan Santyr
RLRiccardo Ludovichetti
Riccardo Ludovichetti
MHMojgan Hodaie
Mojgan Hodaie
Introduction: Peripheral nerve field stimulation (PNFS) for facial pain delivers subcutaneous electrical stimulation to reduce pain. Blood oxygenation level-dependent (BOLD) functional MRI (fMRI) can be used to characterize central effects of neuromodulation techniques such as deep brain stimulation and spinal cord stimulation (SCS). However, the safety and utility of MRI in patients with PNFS have not been established, limiting both clinical MRI use and the application of fMRI in this population. This study evaluated the MRI safety and feasibility of imaging an active SCS implant used for PNFS in patients with facial pain; and defined sequence parameters for concurrent BOLD fMRI acquisition. Methods: An anthropomorphic 3D-printed phantom filled with tissue-mimicking gel and fitted with an SCS implant replicating a patient with PNFS was used for in vitro safety testing. Two phantom experiments evaluated the relationship between (i) head-averaged specific absorption rate (SAR), (ii) time-averaged positive radiofrequency magnetic field component (B1rms+) and maximal temperature rises at critical locations (i.e., distal lead electrodes, cranial coiling, and implantable pulse generator) across clinical and research-based structural and fMRI sequences. For validation, a PNFS patient was scanned using localizer, T1-weighted magnetization-prepared rapid gradient echo, T2-weighted sampling perfection with application-optimized contrasts using different flip angle evolutions, and BOLD fMRI sequences informed by phantom experiments. Results: FMRI during active PNFS is safe under specific conditions, with temperature increases remaining below the 2°C threshold at all monitored locations. Heating had a stronger relationship with head SAR (higher adjusted coefficient of determination [R2] value) than B1rms+, particularly at distal lead electrodes. These in vitro findings informed selection of safe fMRI protocols for in vivo scanning. A patient (n = 1) underwent MRI with no device- or patient-related adverse events. Successful fMRI acquisition was achieved, demonstrating engagement of pain-related regions in the patient. Conclusion: Phantom testing confirmed the safety and feasibility of MRI with an active SCS device configured for facial PNFS. These findings, specific to the tested conditions, underscore the need for context-specific safety evaluations to enable safe MRI in such implantable medical devices.