Elastic waves guided along surfaces dominate applications in geophysics, ultrasonic inspection, mechanical vibration, and surface acoustic wave devices; precise manipulation of surface Rayleigh waves and their coupling with polarised body waves presents a challenge that offers to unlock the flexibility in wave transport required for efficient energy harvesting and vibration mitigation devices. We design elastic metasurfaces, consisting of a graded array of rod resonators attached to an elastic substrate that, together with critical insight from Umklapp scattering in phonon-electron systems, allow us to leverage the transfer of crystal momentum; we mode-convert Rayleigh surface waves into bulk waves that form tunable beams. Experiments, theory and simulation verify that these tailored Umklapp mechanisms play a key role in coupling surface Rayleigh waves to reversed bulk shear and compressional waves independently, thereby creating passive self-phased arrays allowing for tunable redirection and wave focusing within the bulk medium.
In this work we employ additive manufacturing to print a circular array of micropillars on an aluminium slab turning its top surface into a graded index metasurface for surface acoustic waves (SAW). The graded metasurface reproduces a Luneburg lens capable of focusing plane SAWs to a point. The graded index profile is obtained by exploiting the dispersion properties of the metasurface arising from the well-known resonant coupling between the micropillars (0.5 mm diameter and variable length ∼3 mm) and the surface waves propagating in the substrate. From the analytical formulation of the metasurface's dispersion curves, a slow phase velocity mode is shown to arise from the hybridisation of the surface wave with the pillar resonance. This is used to compute the radial height profile corresponding to the refractive index given by Luneburg's equation. An initial validation of the lens design, achieved through ray theory, shows that ray trajectories have a strong frequency dependence, meaning that the lens will only work on a narrow band. An ultrasonic experiment at 500 kHz where plane SAWs are generated with a piezoelectric transducer and a laser scanner measures the out of plane displacement on the metasurface, validates the actual lens performance and the manufacturing technique. Finally, comparison between the ray analysis and experimental results offers insight into the behaviour of this type of metasurface especially in the proximity of the acoustic bandgaps and highlights the possibility for acoustic shielding.
Throughout our engineered environment, many materials exhibit a crystalline lattice structure. The orientation of such lattices is crucial in determining functional properties of these structures, including elasticity and magnetism. Hence, tools for determining orientation are highly sought after. Surface acoustic wave velocities in multiple directions can not only highlight the microstructure contrast, but also determine the crystallographic orientation by comparison to a pre-calculated velocity model. This approach has been widely used for the recovery of orientation in cubic materials, with accurate results. However, there is a demand to probe the microstructure in anisotropic crystals - such as hexagonal close packed titanium. Uniquely, hexagonal structure materials exhibit transverse isotropic linear elasticity. In this work, both experimental and simulation results are used to study the discrete effects of both experimental parameters and varying lattice anisotropy across the orientation space, on orientation determination accuracy. Results summarise the theoretical and practical limits of hexagonal orientation determination by linear SAW measurements. Experimental results from a polycrystalline titanium specimen, obtained by electron back scatter diffraction and spatially resolved acoustic spectroscopy show good agreement (errors of ϕ1=5.14° and Φ=6.99°). Experimental errors are in accordance with those suggested by simulation, according to the experimental parameters. Further experimental results demonstrate dramatically improved orientation results (Φ error <1°). Demonstrating the possibility of achieving results near the theoretical limit by strict control of the experimental parameters.
Additive manufacturing (AM) is a production technology where material is accumulated to create a structure, often through added shaped layers. The major advantage of additive manufacturing is in creating unique and complex parts for use in areas where conventional manufacturing reaches its limitations. However, the current class of AM systems produce parts that contain structural defects (e.g., cracks and pores) which is not compatible with certification in high value industries. The probable complexity of an AM design increases the difficulty of using many non-destructive evaluation (NDE) techniques to inspect AM parts—however, a unique opportunity exists to interrogate a part during production using a rapid surface based technique. Spatially resolved acoustic spectroscopy (SRAS) is a laser ultrasound inspection technique used to image material microstructure of metals and alloys. SRAS generates and detects `controlled’ surface acoustic waves (SAWs) using lasers, which makes it a non-contact and non-destructive technique. The technique is also sensitive to surface and subsurface voids. Work until now has been on imaging the texture information of selective laser melted (SLM) parts once prepared (i.e., polished with m)—the challenge for performing laser ultrasonics in-process is measuring waves on the rough surfaces present on as-deposited parts. This paper presents the results of a prototype SRAS system, developed using the rough surface ultrasound detector known as speckle knife edge detector (SKED)—texture images using this setup of an as-deposited Ti64 SLM sample, with a surface roughness of m, were obtained.
1 January 2018 in Smart and Sustainable Manufacturing Systems
Laser powder bed fusion (LPBF) is an additive manufacturing (AM) process that promises to herald a new age in manufacturing by removing many of the design and material-related constraints of traditional subtractive and formative manufacturing processes. However, the level and severity of defects observed in parts produced by the current class of LPBF systems will not be tolerated in safety-critical applications. Hence, there is a need to introduce information-rich process monitoring to assess part integrity simultaneously with fabrication so that opportune corrective action can be taken to minimize part defects. Spatially Resolved Acoustic Spectroscopy (SRAS) is a uniquely positioned nondestructive acoustic microscopy sensing approach that has been successfully used to probe the mechanical properties and assess the presence of defects in LPBF parts. However, the technique is sensitive to extraneous phenomena, such as surface reflectivity, which occur within the LPBF system and may occlude identification of surface breaking and subsurface defects. With a view to applying the SRAS technique for in-process monitoring in a production-scale LPBF environment and to overcome the foregoing challenge, this study proposes the use of a deep learning convolutional neural network that is termed Densely connected Convolutional Block Architecture for Multimodal Image Regression (DCB-MIR), which invokes SRAS-derived acoustic velocity maps of the part as input data and translates them to an output resembling an optical micrograph. Through this approach, we demonstrate that defects, such as porosity and surface imperfections in titanium alloy and nickel alloy specimens made using LPBF, which were not clearly discernable in the as-measured SRAS acoustic map and were obscured by artifacts in the optical image, are accurately identified. To quantify the accuracy of the approach, the cosine similarity between the predicted output images and target optical images was used as the objective function of DCB-MIR. The cosine similarity between the acquired SRAS signatures and the corresponding as-measured optical micrographs of samples typically ranged between –0.15 and 0.15. In contrast, when the optical micrograph-like images derived from DCB-MIR proposed in this work were compared with the optical signatures, the cosine similarity improved in the range of 0.25 to 0.60.