In this work, we employed an easy hydrothermal method to prepare CuO and ZnO, as well as the prepared composite nanostructured electrodes of CuO@ZnO for supercapacitor applications. The systematic electrochemical performance evaluation of the prepared materials was conducted by cyclic voltammetry (CV), galvanostatic charge–discharge (GCD), and electrochemical impedance spectroscopy (EIS). CuO@ZnO nanocomposite reflected the best charge storing behavior with a specific capacitance of 513 F/g, followed by pristine CuO (190 F/g) and ZnO (416 F/g). The composite also demonstrated 25.67 Wh/kg and 400 W/kg for energy density and power density, respectively, suggesting improved electrochemical performance. Besides, the areal and volumetric capacitances were 0.77 F/cm2 and 4.81 F/cm3, respectively, supported by the structural integrity and enhancement in electroactive materials utilization of the electrode material. Kinetic analysis showed that b values of the samples had mixed capacitive/diffusion-controlled charge storage, while higher diffusion coefficients and standard rate constants were apparent for ion transport or redox kinetics. EIS results showed a 2.14 Ω solution resistance, indicative of a decreased electrical resistivity. An asymmetric supercapacitor device fabricated by CuO@ZnO as the positive electrode and activated carbon (AC) as the negative electrode provided the specific capacitance of 48.57 F/g, energy density of 15.17 Wh/kg, and power density of 535 W/kg. After 10,000 cycles, the capacitance of the device was 76%, indicating good long-term stability.
In this study, the large deformation of a backside-supported snap-fit was analyzed. The backside snap-fit pair consisted of mating part and base part. The mating part was a simple cantilever, and the base part had an opening with a supporting bar. The reaction force of the supporting bar was found to be an important parameter for the assembly and separation of the snap-fit. During our analysis, the supporting bar experienced a large deformation with nonlinear elasticity or plastic damage. Finite element analysis was performed. Stress concentration was observed at the root of the supporting bar and at the bent edge of the base part. Three types of specimens were designed and fabricated for experimental verification. The first specimen was a reference design that was fabricated according to the same design concept as the actual product. The second specimen was designed to reduce the stress concentration. The third specimen had an enriched design to increase the supporting force. The reaction force corresponding to the applied displacement was measured using a testing machine. The load exhibited a highly nonlinear behavior and reached a maximum peak value without causing any apparent damage, after which it decreased with plastic damage. Through numerical and experimental analyses, it was found out that the design of the backside-supported snap-fit could be improved by reducing the stress concentration and increasing the stiffness of the supporting bar.