Wind turbines have become an important source of renewable energy in recent years, but recycling them is difficult due to their material properties. The paper indicates the possibility of using turbine blades to produce elements that can be filled with concrete and used as members of small geotechnical structures: retaining walls, point and well foundations, foundations for railings, fences, road signs, etc., as well as excavation linings and shoring walls. In these solutions, concrete-filled elements of turbine blades constitute a form (formwork) for concrete, protecting it against environmental influences, and can also cooperate with concrete in transferring loads.
28 November 2025 in Środowisko Mieszkaniowe/Housing Environment
This article examines the effectiveness of secondary thermal retrofitting in high-rise buildings constructed using large-panel technology and presents a model for evaluating the efficiency of facade modernisation and aesthetic enhancement methods, with particular emphasis on their energy performance. Three retrofit variants were analysed: increased glazing of balconies, aluminium-clad balcony facades, and a fully glazed facade. Calculations were performed using Audytor software by Sankom, based on an energy audit and in-situ measurements, taking into account the U -value [W/(m 2 ·K)], annual energy demand EHV [kWh/m 2 ·year], cost C [€/m 2 ], and carbon footprint eCO 2 [kgCO 2 /(m 2 ·year)]. The results show that Variant 2 (V2) achieves the greatest energy consumption reduction (32.1%), while Variant 1 (V1) provides the best insulation performance ( U = 0.149 W/m 2 K) and the highest BESM index (1.109). Despite its higher cost (155 €/m²), V2 significantly improves both the building’s energy efficiency and aesthetics. Optimising thermal retrofit methods is a key factor in adapting large-panel buildings to contemporary standards and enhancing residents’ quality of life.
This study investigated an unusual yet practically significant side effect of the thermal retrofit of educational buildings, namely the intensive cooling of internal walls containing uninsulated ventilation ducts. Malfunctioning gravity ventilation led to a reversal of airflow direction, resulting in the inflow of cold air through internal ducts and a deterioration of thermal comfort in the rooms. The cooled zones were identified during thermographic surveys carried out using a FLIR E8-XT camera. Numerical heat transfer analyses were performed in THERM 8.1 (LBNL), while the thermal performance of the building and its seasonal heating demand were calculated in Audytor OZC (Sankom). Three variants were compared: (1) standard design conditions, (2) scenario accounting for the cooling effect of internal walls due to reverse flow of ventilation air, and (3) mechanical ventilation with heat recovery (MVHR). Under the analysed actual operating conditions, the transmission heat loss increased from 27,479 W to 52,473 W, while the annual heating demand rose by 57.6% from 71.3 to 112.4 kWh/(m3∙year). The indoor air temperature decreased by approximately 3 ÷ 7 °C (depending of the space), while the surface temperature near the ducts fell to 5.1 ÷ 12.6 °C at an outdoor temperature of −13 °C. The implementation of MVHR (η = 75%), compared to current situation, reduced the overall heat loss coefficient by 63.9% from 3934.225 to 1417.825 W/K and the annual heating demand by 70.3% from 112.4 to 33.3 kWh/(m3∙year). The results confirm that uncontrolled airflow through internal ventilation ducts may lead to substantial heat losses and localised cooling zones in building elements, effectively acting as thermal bridges.