Naveed Ahmed Chishti

Dr. Naveed Ahmed Chishti

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2019 in Applied Optics
Verified
Journal Article
Closed access
PDF file
Naveed Ahmed ChishtiNaveed Ahmed Chishti
Naveed Ahmed Chishti
SBShazia Bashir
Shazia Bashir
AUAsad Ullah
Asad Ullah
MKMuhmmad Asad Khan
Muhmmad Asad Khan
The effect of magnetic field on laser-induced breakdown spectroscopy of aluminum (Al) plasma has been investigated. Al targets were exposed to Nd:YAG laser pulses at different irradiances ranging from 1  GWcm−2 to 2.7  GWcm−2, under argon (Ar) and neon (Ne) environments at various pressures ranging from 5 torr to 760 torr and at different time delays from 0.42 μs to 9.58 μs. All spectroscopy measurements were performed in the absence and presence of transverse magnetic field of strength 0.9 tesla. When laser irradiance is increased by keeping the pressure (10 torr) and time delay constant (1.25 μs), both excitation temperature (Te) and number density (ne) increase up to certain values. The same trend is observed for Te and ne when the ambient gas pressure of Ar and Ne is increased by keeping the irradiance (1.7  GWcm−2) and time delay constant. At higher irradiances and pressures, saturation is observed, which is attributed to the self-regulating regime of plasma. In the case of time delay, both electron temperature and number density decay exponentially, which is according to the adiabatic expansion model. It is revealed that emission intensity and electron temperature are higher in the presence of magnetic field as compared to the field-free case, which is attributed to magnetic confinement, as well as the joule heating effect. Plasma plume confinement is confirmed by analytical evaluation factor β. β is an analytical factor that is the ratio of plasma pressure to magnetic pressure, i.e., β=Plasma pressureMagnetic pressure. It confirms the validity of magnetic field confinement if β is less than 1. As the evaluated values of β are less than 1 for all cases, they confirm the validity of magnetic confinement.

1 May 2018 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
MAMian Ahsan Ali
Mian Ahsan Ali
SBShazia Bashir
Shazia Bashir
MAMahreen Akram
Mahreen Akram
KMKhaliq Mahmood
Khaliq Mahmood
FHFaizan- Ul- Haq
Faizan- Ul- Haq
SAShahbaz Ahmad
Shahbaz Ahmad

1 June 2018 in Laser and Particle Beams
Verified
Journal Article
Closed access
PDF file
AUAsad Ullah
Asad Ullah
SBShazia Bashir
Shazia Bashir
Naveed Ahmed ChishtiNaveed Ahmed Chishti
Naveed Ahmed Chishti
MKMuhmmad Asad Khan
Muhmmad Asad Khan
AHAsma Hayat
Asma Hayat
The effect of magnetic field on the plasma parameters and surface modification of Cu-alloy has been investigated. For this purpose, we have employed Nd: YAG laser at various irradiances ranging from 1.9 to 5 GW/cm2 to irradiate Cu-alloy under 5 torr pressure of argon, neon, and helium. The evaluated values of excitation temperature (Texc) and electron number density (ne) of Cu-alloy plasma explored by laser-induced breakdown spectroscopy technique are higher in the presence of 1.1 Tesla magnetic field as compared with field-free case. It is true at all irradiances as well as under all environmental conditions. It is also found that trends of both Texc and ne are increasing with increasing laser irradiance from 1.9 to 4.4 GW/cm2. For the highest used irradiance 5 GW/cm2, the decrease in both parameters is observed. The analytically calculated values of thermal beta, directional beta, confinement radius, and diffusion time for laser-irradiated Cu-alloy plasma confirm the validity of magnetic confinement. Scanning electron microscope analysis is utilized to study the surface modifications of laser-irradiated Cu samples and reveals the formation of islands, craters, cones, and droplets. The finer-scale surface structures are grown in case of magnetic. It is also revealed Texc and ne play a substantial part in the growth of surface structures on Cu-alloy.

1 January 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
MKMuhmmad Asad Khan
Muhmmad Asad Khan
SBShazia Bashir
Shazia Bashir
Naveed Ahmed ChishtiNaveed Ahmed Chishti
Naveed Ahmed Chishti
EBEbenezer Bonyah
Ebenezer Bonyah
AUAsad Ullah
Asad Ullah
Zubair AhmadZubair Ahmad
Zubair Ahmad
Plasma parameters of magnetically confined Cobalt (Co) plasma have been evaluated by using laser-induced breakdown spectroscopy at various laser irradiances, under different ambient pressures of two environments such as Ar and Ne and at different time delays. The effect of laser irradiance on Co plasma is exposed in the presence and absence of a Transverse Magnetic field (TMF) while keeping environmental gas pressure constant, i.e., 10 Torr. For this purpose, Co pellets were exposed to Nd: YAG laser (1064 nm, 10 ns) at various laser irradiances ranging from 1 to 2.9 GW cm−2. To investigate the impact of background gas pressures, Co pellets were exposed to various pressure varying from 5 to 760 Torr of Ar and Ne. In the case of time delay variation, the Co plasma parameters Texc and ne decrease exponentially. A significantly pronounced effect of the presence of an external TMF of strength 0.9 T on time-integrated Co plasma parameters has been revealed. Plasma parameters Texc and ne are considerably increased in the presence of TMF in both ambient environments because of being constrained to a very small region due to which collisions will be enhanced. Implementation of the 0.9 T TMF on a laser-induced plasma of Co is responsible for the confinement of plasma. The surface morphology of laser-irradiated Co samples was also discussed to confirm the effect of TMF. Fine and uniform structures are observed in samples treated in the presence of TMF by using the SEM technique.

26 February 2024 in Physical Review A
Verified
Journal Article
Closed access
PDF file
SGStefania Gravina
Stefania Gravina
Naveed Ahmed ChishtiNaveed Ahmed Chishti
Naveed Ahmed Chishti
ACAntonio Castrillo
Antonio Castrillo
LGLivio Gianfrani
Livio Gianfrani
ASAlessia Sorgi
Alessia Sorgi
Gianluca GalzeranoGianluca Galzerano
Gianluca Galzerano
Doppler-broadening gas thermometry is extended to the deep-ultraviolet domain using a comb-locked laser frequency chain, expressly developed for precision spectroscopy of mercury vapors at the wavelength of 253.7 nm, in coincidence with the (6s2)S01→(6s6p)P13 intercombination line. The system is based on a double-stage second-harmonic generation process of an external-cavity diode laser at 1014.8 nm, which is frequency locked to a self-referenced optical-frequency-comb synthesizer by means of an efficient nonlinear frequency-mixing scheme. An absolute frequency axis in the UV region is produced by scanning the comb repetition rate, with the entire frequency chain following the reference comb tooth. The complete characterization of the phase noise of the comb-locked near-infrared laser demonstrates line-emission narrowing down to the limit imposed by the coherence of the comb teeth. After a proper processing of the phase noise, the Gaussian and Lorentzian components of the width of the UV radiation are determined. This is useful to estimate the instrumental perturbation to the probed mercury line for the aims of thermodynamic temperature metrology. In this regard, the preliminary spectroscopic results are quite promising, despite the difficulties arising from the short wavelength of operation.

24 May 2024 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SGStefania Gravina
Stefania Gravina
Naveed Ahmed ChishtiNaveed Ahmed Chishti
Naveed Ahmed Chishti
SBSimona Di Bernardo
Simona Di Bernardo
EFEugenio Fasci
Eugenio Fasci
ACAntonio Castrillo
Antonio Castrillo
LGLivio Gianfrani
Livio Gianfrani
We report on precision spectroscopy of the 6s2 S01→6s6p P13 intercombination line of mercury in the deep ultraviolet, by means of a frequency-comb referenced, wavelength-modulated, saturated absorption technique. This method allowed us to perform sub-Doppler investigations with an absolute frequency axis at 254 nm, while ensuring a relatively high signal-to-noise ratio. The absolute line center frequencies of the Hg200 and Hg202 bosonic isotopes were measured with a global uncertainty of 8 and 15 kHz (namely, 6.8×10−12 and 1.3×10−11, in relative terms), respectively, the statistical and systematic components being significantly reduced as compared to past determinations. This remarkable result was achieved also thanks to an in-depth study of the ac Stark effect. Furthermore, we found the most accurate Hg200−Hg202 isotope shift ever obtained before, namely, 5 295 57 0±15stat±8syst  kHz.