Doppler-broadening gas thermometry is extended to the deep-ultraviolet domain using a comb-locked laser frequency chain, expressly developed for precision spectroscopy of mercury vapors at the wavelength of 253.7 nm, in coincidence with the intercombination line. The system is based on a double-stage second-harmonic generation process of an external-cavity diode laser at 1014.8 nm, which is frequency locked to a self-referenced optical-frequency-comb synthesizer by means of an efficient nonlinear frequency-mixing scheme. An absolute frequency axis in the UV region is produced by scanning the comb repetition rate, with the entire frequency chain following the reference comb tooth. The complete characterization of the phase noise of the comb-locked near-infrared laser demonstrates line-emission narrowing down to the limit imposed by the coherence of the comb teeth. After a proper processing of the phase noise, the Gaussian and Lorentzian components of the width of the UV radiation are determined. This is useful to estimate the instrumental perturbation to the probed mercury line for the aims of thermodynamic temperature metrology. In this regard, the preliminary spectroscopic results are quite promising, despite the difficulties arising from the short wavelength of operation.
25 August 2023 in Physical Chemistry Chemical Physics
The absolute frequency of several C2H2 rovibrational transitions, carefully selected by the theory of spectroscopic network, has been measured with an accuracy of 15 kHz. Based on the MARVEL procedure, para- and ortho-energy levels were determined.
We report on the development, characterization, and test of a comb-locked cavity ring-down spectrometer (CL-CRDS) operating in the spectral region around 1.39 µm. The system is based on the use of a hemispherical optical resonator with a finesse as high as ∼507000, which gives an empty-cavity ring-down time of about 285 µs. An Allan-Werle analysis on repeated acquisitions of the ring-down time at a fixed laser frequency suggests a minimum detectable absorption coefficient of 2×10−12cm−1 for the optimum integration time of 45 s. This limit can be exceeded by adopting the strategy of long-term spectral averaging. Taking advantage of the frequency stability guaranteed by the optical frequency comb, the CL-CRDS spectra were averaged over more than two days, thus removing efficiently the effect of mechanical, acoustic, and thermal noises. As a result, we could achieve a minimum detectable absorption coefficient as low as 3.7×10−13cm−1, which corresponds to a limit of detection for H2O in N2 of nine parts per trillion and a H2O partial pressure of 2×10−8 Pa (or 2×10−10 mbar). The potentialities of our approach are demonstrated by recording the absorption features of HD16O and HD18O in flows of ultra-high-purity N2 and ambient air, respectively.
Doppler-free saturated-absorption Lamb dips are observed for weak vibration-rotation transitions of C2H2 between 7167 and 7217 cm−1, using a frequency-comb assisted cavity ring-down spectrometer based on the use of a pair of phase-locked diode lasers. We measured the absolute center frequency of sixteen lines belonging to the 2 band, targeting ortho and para states of the molecule. Line pairs of the P and Q branches were selected so as to form a ‘V’-scheme, sharing the lower energy level. Such a choice made it possible to determine the rotational energy separations of the excited vibrational state for J-values from 11 to 20. Line-center frequencies are determined with an overall uncertainty between 3 and 13 kHz. This is over three orders of magnitude more accurate than previous experimental studies in the spectral region around the wavelength of 1.4 μm. The retrieved energy separations provide a stringent test of the so-called MARVEL method recently applied to acetylene.
Quantitative UV laser absorption spectroscopy is implemented to measure the strength of the intercombination transition of Hg atoms near the wavelength of 253.7 nm and to retrieve the lifetime of the excited state. Tunable, single-mode, coherent radiation in the deep UV is produced through a double-stage second-harmonic generation process, starting from the output radiation of an external-cavity diode laser at 1014.8 nm. This latter is referenced to an optical frequency comb synthesizer. The measurement strategy exploits the relationship between the strength of an optical transition and the spontaneous emission Einstein coefficient. The complete uncertainty budget leads to an overall relative uncertainty of 0.6%, with a statistical contribution of 0.28 ns, which is the lowest ever obtained for the lifetime. The new value, amounting to , compares well with most of the past determinations within two times the quoted uncertainties. Despite this, it does not agree with the weighted average of the 12 prior values, thus suggesting that a critical reassessment of the uncertainty of some of the past measurements is probably necessary.
We report on precision spectroscopy of the intercombination line of mercury in the deep ultraviolet, by means of a frequency-comb referenced, wavelength-modulated, saturated absorption technique. This method allowed us to perform sub-Doppler investigations with an absolute frequency axis at 254 nm, while ensuring a relatively high signal-to-noise ratio. The absolute line center frequencies of the and bosonic isotopes were measured with a global uncertainty of 8 and 15 kHz (namely, and , in relative terms), respectively, the statistical and systematic components being significantly reduced as compared to past determinations. This remarkable result was achieved also thanks to an in-depth study of the ac Stark effect. Furthermore, we found the most accurate isotope shift ever obtained before, namely, .