27 February 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
SCShi Chen
Shi Chen
NTNengling Tai
Nengling Tai
CFChunju Fan
Chunju Fan
JLJian Liu
Jian Liu
SHShubin Hong
Shubin Hong
Crowbar circuit is a preferred solution to maintaining wind generators connected to the grid during a disturbance. However, the activation of crowbar protection will lead to an obvious difference between the positive sequence impedance of wind generators and the negative sequence one. This study analyses the influence of this unique fault characteristic of doubly‐fed induction generators (DFIGs) on the three zones of distance relays. When the transmission line emanates from a DFIG‐based wind farm, there exists a high probability that the conventional protective zones of distance relays fail to operate. Hence, an adaptive branch coefficient is proposed to calculate the zone 2 setting according to the fault type and equivalent sequence impedances of wind generators. The proposed adaptive setting principle realises a better coverage of zone 2 and enhances the reliability and sensitivity of the relays. Simulation results verify the improvement of the protective zone of distance relays.

4 June 2018 in Energies
Verified
Journal Article
Open access
PDF file
CLCheng Lv
Cheng Lv
XZXiaodong Zheng
Xiaodong Zheng
Nengling TaiNengling Tai
Nengling Tai
SCShi Chen
Shi Chen
With the promotion of distributed energy and direct current (DC) loads, the DC microgrid is able to provide a higher power quality and improve the grid efficiency. Various technical issues in DC microgrids are still to be addressed, particularly a proper protection scheme for fault detection and isolation in DC microgrids utilizing voltage source converters (VSCs). In this paper, the pole-to-pole DC fault transient behavior of the VSC-based microgrids is firstly analyzed with four successive stages, and then the exact requirements for protections are presented. Furthermore, a novel single-ended protection scheme based on local transient signals is proposed, which needs no data transmission or synchronization between two ends, ensuring the speed. A four-terminal DC microgrid model was built in PSCAD/EMTDC. Numerous simulations have demonstrated the validity of the proposed scheme.

14 July 2025 in Energies
Verified
Journal Article
Open access
PDF file
JLJinjiao LIN
Jinjiao LIN
JDJingyan Du
Jingyan Du
SCShi Chen
Shi Chen
XWXinying Wang
Xinying Wang
HLHaodong Long
Haodong Long
Chuyang WangChuyang Wang
Chuyang Wang
Phase-shifting transformers play a crucial role in power grid stability and efficiency. They adjust phase differences between loads, improve transmission efficiency, and balance loads during large-scale power transmission and grid integration. However, traditional mechanical phase-shifting transformers use fixed-tap designs with limited taps, preventing continuous and precise adjustments. This discrete adjustment method affects control accuracy and optimal tap position selection for proper power flow. This paper proposes a hybrid open-loop and closed-loop control strategy. This strategy maintains the phase-shifting transformer at its optimal tap position, enhancing system regulation precision and control effectiveness.

12 October 2026 in Energies
Verified
Journal Article
Open access
PDF file
Xuefeng GeXuefeng Ge
Xuefeng Ge
QZQi Zhou
Qi Zhou
XFXin Fang
Xin Fang
SCShi Chen
Shi Chen
To address the delayed dynamic response and susceptibility to overcurrent surges of the triple-active-bridge (TAB)-based modular multilevel DC-link T-type converter power electronic transformer (MMDTC-PET) under load step transients, this paper proposes a composite model predictive control (MPC) strategy to enhance the system’s disturbance rejection capability. The proposed strategy adopts a hierarchical control architecture comprising a proportional-integral (PI) outer power loop and an MPC inner loop. To tackle the heavy computational burden caused by multi-port coupling, dimensionality reduction is performed by equating the phase-shift ratios of the two primary-side ports of the TAB, which effectively mitigates the computational cost. Furthermore, a dynamic overcurrent hard-constraint penalty term and a control-effort smoothing term are incorporated into the multi-objective cost function. This not only achieves steady-state error-free tracking of the output voltage but also enhances physical operational safety under complex conditions at the algorithmic level. Comparative simulation results under various operating conditions demonstrate that, compared with the traditional PI-based phase-shift control, the proposed strategy exhibits a faster dynamic response under load step conditions. Moreover, it suppresses transient power overshoots and overcurrent impacts during input voltage sags and recoveries, thereby significantly improving the transient disturbance rejection capability and operational robustness of the system.