Proton exchange membrane fuel cells are a clean energy technology with wide application in transportation and stationary energy systems. Due to the problem of voltage degradation under long-term dynamic loads, predicting their performance degradation trend is of great significance for extending the life of proton exchange membrane fuel cells and improving system reliability. This study adopts a data-driven approach to construct a degradation prediction model. In view of the problem of many input parameters and complex distribution of degradation features, a neural network model based on a multi-head attention mechanism and class token is first proposed to analyze the impact of different operating parameters on the output voltage prediction. The importance of each input variable is quantified by the attention weight matrix to assist feature screening. Subsequently, a prediction model is constructed based on Transformer to characterize the voltage degradation trend of fuel cells under dynamic conditions. The experimental results show that the root mean square error and mean absolute error of the model in the test phase are 0.008954 and 0.006590, showing strong prediction performance. Based on the importance evaluation provided by the first model, 11 key parameters were selected as inputs. After this input simplification, the model still maintained a prediction accuracy comparable to that of the full-feature model. This result verifies the effectiveness of the feature screening strategy and demonstrates its contribution to improved generalization and robustness.
29 July 2025 in International Journal of Hydrogen Energy
To address the difficulty of simultaneously achieving effective heat dissipation and adequate humidification in open-cathode air-cooled proton exchange membrane fuel cells (PEMFCs) under medium and high power operation, this study proposes a hydrothermal management strategy based on coordinated ultrasonic atomization humidification and fan speed regulation. A three-dimensional single-cell multiphysics model is developed and validated using a 300 W experimental platform. The effects of atomization frequency and water temperature on stack performance and internal hydrothermal distribution are systematically investigated. Results show that ultrasonic atomization provides inlet precooling, latent heat absorption, and active region humidification, thereby improving hydrothermal uniformity within the stack. Under the optimal condition of 100 kHz and 55 °C, the peak stack power increases by 21.0% to 319.00 W, while voltage consistency and surface temperature uniformity are also improved. Analysis based on the Stokes number and Dalton’s law of partial pressures indicates that the optimum results from a balance between suppressing droplet agglomeration and inertial deposition, and limiting oxygen dilution caused by excessive water vapor. The proposed strategy provides a compact and practical approach for improving the stability, uniformity, and efficiency of air-cooled PEMFCs.
Onboard PEM fuel cells operate under dynamic duty cycles where monitoring signals deeply alias load-induced transients with intrinsic degradation. Conventional single metrics cannot separate operational fluctuations from genuine aging, while multi-dimensional indicators introduce cross-physical-field coupling redundancy and lack causal-temporal evidence. To address these challenges, this paper proposes a physics-informed “decoupling-interpretation-prediction” framework. Health state is explicitly represented by two complementary indicators: performance attenuation (PA) and consistency deterioration (CD). A core feature triad, validated by partial correlation analysis (average 0.76, p<0.01), captures principal health information; Gaussian process regression establishes condition-dependent healthy baselines (R²: 0.87–0.99). K-Means clustering (silhouette score: 0.736) identifies four operating modes. XGBoost-SHAP attribution reveals mode-specific degradation pathways: idle variable-load conditions exhibit a dual acceleration effect from high-potential corrosion and dynamic water-thermal imbalance, with 56.88% of operating points in a “high PA but acceptable CD” risk zone, whereas high-load conditions keep all early failure risks below 0.45%. Under low-load conditions, current-density fluctuation shows a negative SHAP contribution to CD, suggesting a beneficial “micro-fluctuation pump” effect within a bounded window. Granger causality tests confirm that PA and CD temporally precede key polarization-curve parameter deterioration (p<0.05), providing early-warning evidence. An attention-based multi-task LSTM validates PA/CD predictability with R² exceeding 0.97, while attention visualization reveals distinct temporal dependency patterns between the two indicators. The framework transforms health management from passive response to mode-adaptive active regulation, offering a systematic pathway for interpretable PEMFC health management under dynamic conditions.
1 January 2022 in Wireless Communications and Mobile Computing
With the rapid development of the Internet of Things, sparse code multiple access (SCMA), which aims to promote spectrum efficiency and support massive connectivity in the future beyond fifth‐ and sixth‐generation massive machine‐type communication (mMTC) scenarios, has been widely investigated. To improve the bit error rate (BER) performance of the SCMA system in the uplink Rayleigh fading channel, we propose a novel deep learning‐based SCMA codec scheme. The proposed scheme consists of an equalization network‐aided decoder network and a denoising autoencoder‐ (DAE‐) based encoder network. At the decoder, an equalization network and a multiuser detection network constitute the decoder network. The equalization network, composed of two deep neural network (DNN) units, compensates for the phase shift of the signal through the fading channel, which improves the antifading capability of the system. At the encoder, a complete DAE is constructed, which introduces an extra noise layer at the input of the encoder that yields a robust encoder output representation, improving the antinoise capability of the system. We use an end‐to‐end training method to train the SCMA codec and optimize the parameters and structural model of the neural network. Simulation results show that our proposed scheme can reduce the detection time and improve the BER performance of the system in the uplink Rayleigh fading channel.