Atul Mishra

Atul Mishra

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Journal of Cancer Research and Therapeutics
Verified
Journal Article
Open access
AMAtul Mishra
Atul Mishra
RPRamji Pathak
Ramji Pathak
KMKailash Kumar Mittal
Kailash Kumar Mittal
ASAnoop Kumar Srivastava
Anoop Kumar Srivastava
MDMaurya Surendrakumar Dayashankar
Maurya Surendrakumar Dayashankar
SSSudesh Kumar Singh
Sudesh Kumar Singh
Aim: In this study, efficacy of collapsed cone algorithm-generated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) were evaluated for treatment of thoracic esophageal cancer. Materials and Methods: Ten previously treated patients with VMAT were considered for evaluation. The planning parameters were evaluated in terms of max dose, mean dose, Homogeneity Index, Conformity Index for planning target volume, and organ at risk doses. Total monitor unit, treatment time, and gamma passing index were also reported. Results: The target dose coverage of the VMAT and IMRT plans achieved the clinical dosimetric criteria for all ten patients in the evaluation. Under the condition of equivalent target dose distribution, the VMAT plan’s Conformity Index, monitor unit, treatment time, and gamma passing index rate were superior than in the IMRT plan, and the result was statistically significant. Conclusion: Collapsed cone algorithm-based VMAT can have a more effective and better approach for esophageal cancer than IMRT

1 January 2025 in Journal of Cancer Research and Therapeutics
Verified
Journal Article
Open access
ASAnoop Kumar Srivastava
Anoop Kumar Srivastava
AMAtul Mishra
Atul Mishra
SMSumanta Manna
Sumanta Manna
NYNeha Yadav
Neha Yadav
KMKailash Kumar Mittal
Kailash Kumar Mittal
SMSurendra Prasad Mishra
Surendra Prasad Mishra
Objective: The primary aim of radiation therapy planning is to achieve optimal tumor control probability (TCP) while minimizing the risk of normal tissue complications (NTCPs). Traditionally, the dose–volume histogram has been a reliable tool for evaluating volumetric dose distribution in treatment plans. This study aims to assess the radiobiological efficacy of volumetric modulated arc therapy (VMAT), step-and-shoot intensity-modulated radiation therapy (ss-IMRT), and dynamic IMRT (d-IMRT) in the treatment of thoracic tumors. Materials and Methods: This study involved 13 patients diagnosed with squamous cell carcinoma of the thorax. Thirteen patients with squamous cell carcinoma of the thoracic site were included in this study. For each patient, three treatment plans (VMAT, ss-IMRT, and d-IMRT) were created, and the corresponding radiobiological parameters, such as equivalent uniform dose (EUD), TCP, and NTCP, were computed using Niemierko and LKB model for all 39 treatment plans using BIOSUITE software. Results: The estimated average TCPs for ss-IMRT, d-IMRT, and VMAT are 61.51%, 62.86%, and 63.09%, respectively. Moreover, the average NTCPs observed for the organ at risk, lung, for ss-IMRT, d-IMRT, and VMAT were 3.27%, 1.96%, and 1.29%, respectively. In terms of the spinal cord, the average NTCPs for ss-IMRT, d-IMRT, and VMAT were 0.07%, 0.0%, and 0.0%, respectively. For the heart, the average NTCPs for ss-IMRT, d-IMRT, and VMAT were 0.10%, 0.12%, and 0.13%, respectively. Conclusions: The findings of this study suggest that VMAT might give equivalent TCP with less NTCP when compared to IMRT. The development of treatment planning techniques based on radiobiological factors aided in the prudent selection of physical parameters to attain high TCP and low NTCP.

1 January 2023 in Journal of Biomedical Physics and Engineering
Verified
Journal Article
Open access
PDF file
AMAtul Mishra
Atul Mishra
RPRamji Pathak
Ramji Pathak
TVTeerth Raj Verma
Teerth Raj Verma
ASAnoop Kumar Srivastava
Anoop Kumar Srivastava
SMSurendra Prasad Mishra
Surendra Prasad Mishra
SSSudesh Kumar Singh
Sudesh Kumar Singh
Background: In Radiotherapy, computation of dose is important since in a small field with heterogeneity, dose is usually computed with discrepancies.Objective: The present study was aimed to evaluate the dosimetry of treatment planning algorithms in lung equivalent heterogeneous medium for Volumetric Modulated Arc Therapy (VMAT) with step and shoot Intensity-Modulated Radiation Therapy (ss-IMRT), and dynamic Intensity-Modulated Radiation Therapy (d-IMRT).Material and Methods: In this experimental study, Computerized Imaging Reference System (CIRS) phantom was used with an inhomogeneous Racemosa wood cylinder for two types of tumors, namely, Left Lung Central Tumor (LCT) and Left Lung Peripheral Tumor (LPT) in the CIRS left lung cavity. The computed tomography (CT) datasets were employed with the generation of VMAT, d-IMRT and ss-IMRT plans for the LCT and LPT irradiated with 6 MV photon beams. In this study, the accuracy and efficacy of two algorithms: Monte Carlo (MC) and the Pencil Beam (PB), from the Monaco treatment planning system (TPS), were tested by using Gafchromic EBT3 films and CIRS thorax phantom.Results: Regardless of treatment techniques, both algorithms exhibited higher divergence in LPT than LCT. In both LCT and LPT, the highest deviation was near the tumor-lung junction. However, the deviation was higher in the PB algorithm than MC algorithm, with a minimally acceptable variation of -0.8%. Conclusion: The MC algorithm shows more consistency for EBT3 measured dose in lung equivalent heterogeneous medium. However, accurate dose predictions are complicated due to electronic disequilibrium within and at the interface of inhomogeneity. These constraints may cause variations from the anticipated outcomes of the treatments.

1 January 2025 in Journal of Medical Physics
Verified
Journal Article
Open access
PSPratibha Singh
Pratibha Singh
MSManoj Kumar Singh
Manoj Kumar Singh
AMAtul Mishra
Atul Mishra
Aim: This study aims to compare the dosimetric efficacy of RapidArc (RA) and intensity-modulated radiation therapy (IMRT) in the treatment of head-and-neck cancer, focusing on treatment efficiency and organ at risk (OAR) dose. Materials and Methods: A cohort of 10 patients with head-and-neck cancer was recreated for RA, which was earlier treated with IMRT techniques. Dosimetric parameters evaluated or planning target volume (PTV) included monitor units (MUs), beam on time (BoT), gamma passing rate (GP), and various normal tissue dose indices such as V95, V90, V50, V25, and gradient indices (gradient index [GI], low GI [LGI], high GI). In addition, doses of OARs, including the spinal cord, brainstem, cochleae, esophagus, lips, larynx, and parotid glands, were compared. Results: RA demonstrated significant improvements in treatment efficiency, requiring fewer MU and shorter BoT, while maintaining comparable GP to IMRT. RA achieved a lower LGI, indicating better sparing of normal tissues from intermediate doses. Most other dosimetric parameters, including those for the spinal cord, parotid glands, and PRV spinal cord, demonstrated significant differences, with the RA technique showing superior performance. Conclusion: This study highlights the dosimetric superiority of RA over IMRT, with significantly fewer MU, reduced BoT, and comparable GPs. RA achieved slightly higher mean PTV doses with similar homogeneity and conformity while delivering lower doses to critical OARs, such as the spinal cord, PRV spinal cord, and parotid glands, making it clinically advantageous.

20 February 2025 in ecancermedicalscience
Verified
Journal Article
Open access
AMAtul Mishra
Atul Mishra
SMSumanta Manna
Sumanta Manna
KMKailash Kumar Mittal
Kailash Kumar Mittal
SSSharad Singh
Sharad Singh
NYNeha Yadav
Neha Yadav
Evaluation of radiation treatment plan quality in head and neck cancer: a comparative analysis of RapidArc technique with flattening filter and flattening fil

14 February 2026 in Indian Journal of Radiology and Imaging
Verified
Journal Article
Open access
SYSantosh Kumar Yadav
Santosh Kumar Yadav
RSRohit Sharma
Rohit Sharma
AMAtul Mishra
Atul Mishra
ASA.K. Srivastava
A.K. Srivastava
AKAbhishek Kumar
Abhishek Kumar
Scattered radiation in diagnostic radiology is a source of radiation exposure to medical staff. It mostly originates from patient interaction during X-ray exposure. Its intensity is determined by technical conditions, including kilovoltage (kVp), phantom thickness, and field size. This research endeavors to quantify scatter radiation with an ionization chamber-based survey meter for different conditions of kVp and phantom thickness to assess its effect in a digital radiographic room. A GE Definium XR-8000 digital X-ray machine served as the source of radiation. Scattered radiation at a standard distance and angle was measured with the help of the Fluke 451P ionization chamber-based survey meter. Both a basic water phantom and a general radiographic polymethyl methacrylate phantom were employed with varying thicknesses (5–25 cm and 10–40 mm, respectively). Scattered radiation was measured across different tube voltages (50–125 kVp), while mAs and source-to-image distance were kept constant. Scattered radiation was proportional to both tube voltage and phantom thickness. In 25-cm water phantom thickness, scatter went from 0.38 mR at 50 kVp to 2.05 mR at 125 kVp. A rise in water phantom thickness from 5 to 25 cm at 80 kVp revealed a rise in scatter from 1.67 to 1.9 mR. The radiographic phantom exhibited a similar trend. Present values were higher as compared with values in literature, because the mAs setting was higher for this investigation. This study shows increased scatter with higher kVp and phantom thickness, emphasizing optimized parameters and ALARA (As Low As Reasonably Achievable) for radiation safety.