ASA.K. Srivastava
A.K. Srivastava
AKAbhishek Kumar
Abhishek Kumar
Scattered radiation in diagnostic radiology is a source of radiation exposure to medical staff. It mostly originates from patient interaction during X-ray exposure. Its intensity is determined by technical conditions, including kilovoltage (kVp), phantom thickness, and field size. This research endeavors to quantify scatter radiation with an ionization chamber-based survey meter for different conditions of kVp and phantom thickness to assess its effect in a digital radiographic room. A GE Definium XR-8000 digital X-ray machine served as the source of radiation. Scattered radiation at a standard distance and angle was measured with the help of the Fluke 451P ionization chamber-based survey meter. Both a basic water phantom and a general radiographic polymethyl methacrylate phantom were employed with varying thicknesses (5–25 cm and 10–40 mm, respectively). Scattered radiation was measured across different tube voltages (50–125 kVp), while mAs and source-to-image distance were kept constant. Scattered radiation was proportional to both tube voltage and phantom thickness. In 25-cm water phantom thickness, scatter went from 0.38 mR at 50 kVp to 2.05 mR at 125 kVp. A rise in water phantom thickness from 5 to 25 cm at 80 kVp revealed a rise in scatter from 1.67 to 1.9 mR. The radiographic phantom exhibited a similar trend. Present values were higher as compared with values in literature, because the mAs setting was higher for this investigation. This study shows increased scatter with higher kVp and phantom thickness, emphasizing optimized parameters and ALARA (As Low As Reasonably Achievable) for radiation safety.

24 February 2026 in Indian Journal of Radiology and Imaging
Verified
Journal Article
Open access
PDF file
AKAbhishek Kumar
Abhishek Kumar
SBShuchi Bhatt
Shuchi Bhatt
AMAtul Mishra
Atul Mishra
ASA.K. Srivastava
A.K. Srivastava
X-ray examinations are integral to medical diagnostics but pose risks from ionizing radiation. Adhering to the ALARA (as low as reasonably achievable) principle in diagnostic radiography is essential. This study evaluates the accuracy and reliability of entrance skin dose (ESD) values displayed on digital radiographic X-ray machine by comparing them with estimated ESD values during common radiographic examinations. ESD was estimated for 250 radiographs of 150 patients (90 females, 60 males) undergoing five common radiographic views: lumbosacral (LS) spine anterior–posterior (AP)/lateral (LAT), pelvis AP, and abdomen supine/erect. Using the formula, estimated ESD values were calculated and compared with displayed ESD values from the console of the digital X-ray machine. The mean estimated and displayed ESD values were: LS spine AP (1.31 mGy, 0.92 mGy), LS spine LAT (2.12 mGy, 1.63 mGy), pelvis AP (0.69 mGy, 0.62 mGy), abdomen supine (0.67 mGy, 0.65 mGy), and abdomen erect (1.44 mGy, 1.06 mGy). Statistical analysis revealed a significant correlation between estimated and displayed ESD values across all views (p <0.001). The intraclass correlation coefficient ranged from 62.60 to 84.30%, indicating moderate to strong agreement. These findings were compared with studies from Canada, India, and the UK. Displayed ESD values showed significant deviation from the independently estimated ESD values, indicating that console-generated estimates provide only an approximate indication of patient exposure. Therefore, they should not be considered a precise substitute for direct dosimetric measurements. Reliable ESD values displayed on radiographic equipment facilitate effective radiation protection measures. Incorporating regular ESD monitoring into clinical practice can enhance patient safety and adherence to radiation safety protocols in diagnostic radiology.

11 September 2026 in Indian Journal of Radiology and Imaging
Verified
Journal Article
Open access
SVSatyam Verma
Satyam Verma
RSRohit Sharma
Rohit Sharma
AMAtul Mishra
Atul Mishra
AYArun Kumar Yadav
Arun Kumar Yadav
AKAbhishek Kumar
Abhishek Kumar
ASAjai Kumar Srivastava
Ajai Kumar Srivastava
To evaluate and compare conventional radiation dose metrics (computed tomography dose index volume [CTDIvol] and dose length product [DLP]) with size-specific dose estimates (SSDEs) in adult patients undergoing non-contrast computed tomography (NCCT) abdomen examinations. This study aimed to evaluate radiation dose metrics in adult NCCT abdomen examinations with particular emphasis on SSDE and to compare the findings with international diagnostic reference levels. A retrospective analysis of 130 adult patients was performed. CTDIvol and DLP were recorded from scanner-generated dose reports, and effective dose was calculated using standard abdominal conversion coefficients. SSDE was derived using patient anteroposterior and lateral body dimensions based on American Association of Physicists in Medicine TG-204 recommendations. The mean CTDIvol and DLP were 8.59 ± 2.13 mGy and 405.2 ± 121.46 mGy·cm, respectively, with a calculated effective dose of 6.08 ± 1.82 mSv. The mean SSDE was 13.53 ± 3.03 mGy, significantly higher than CTDIvol (p < 0.01). All dose indices were below the American College of Radiology and International Atomic Energy Agency reference levels. The study demonstrates that reliance on CTDIvol significantly underestimates the absorbed radiation dose in adult NCCT abdomen examinations. Incorporating SSDE provides a more accurate, patient-specific estimation of actual radiation dose.