Scattered radiation in diagnostic radiology is a source of radiation exposure to medical staff. It mostly originates from patient interaction during X-ray exposure. Its intensity is determined by technical conditions, including kilovoltage (kVp), phantom thickness, and field size. This research endeavors to quantify scatter radiation with an ionization chamber-based survey meter for different conditions of kVp and phantom thickness to assess its effect in a digital radiographic room. A GE Definium XR-8000 digital X-ray machine served as the source of radiation. Scattered radiation at a standard distance and angle was measured with the help of the Fluke 451P ionization chamber-based survey meter. Both a basic water phantom and a general radiographic polymethyl methacrylate phantom were employed with varying thicknesses (5–25 cm and 10–40 mm, respectively). Scattered radiation was measured across different tube voltages (50–125 kVp), while mAs and source-to-image distance were kept constant. Scattered radiation was proportional to both tube voltage and phantom thickness. In 25-cm water phantom thickness, scatter went from 0.38 mR at 50 kVp to 2.05 mR at 125 kVp. A rise in water phantom thickness from 5 to 25 cm at 80 kVp revealed a rise in scatter from 1.67 to 1.9 mR. The radiographic phantom exhibited a similar trend. Present values were higher as compared with values in literature, because the mAs setting was higher for this investigation. This study shows increased scatter with higher kVp and phantom thickness, emphasizing optimized parameters and ALARA (As Low As Reasonably Achievable) for radiation safety.
10 October 2025 in Indian Journal of Radiology and Imaging
Radiation protection is at a crossroads in the era of digital imaging. Although radiographic modalities have made tremendous leaps in diagnostic sensitivity, they have, in turn, added new challenges in guaranteeing proper protection against radiation. Inconsistencies in exposure protocols, lack of health worker awareness, and differing utilization of dose optimization aids still undermine the dictums of justification and ALARA (As Low As Reasonably Achievable). This commentary calls upon the radiology and medical imaging community to embrace a concerted approach to radiation safety, based on international standards and informed by strong education, technology, and policy infrastructures. Such concerted practice has the potential to harmonize safety culture across health care systems and enable imaging professionals to reduce patient and occupational exposure without diminishing diagnostic effectiveness.
Neurocysticercosis (NCC), a parasitic infection of the central nervous system caused by Taenia solium larvae, is a leading cause of acquired epilepsy in endemic regions. This case describes a 40-year-old male who presented with chronic headache, dizziness, and a recent seizure episode. He had no prior history of systemic illness, tuberculosis, or neurological disorders. Magnetic Resonance Imaging (MRI) of the brain revealed multiple ring-enhancing lesions with an eccentric scolex in the cerebral and cerebellar hemispheres, accompanied by surrounding edema, confirming the diagnosis of neurocysticercosis. Additional lesions in extraocular, facial, and tongue muscles were consistent with myocysticercosis, an uncommon but clinically significant manifestation that may mimic inflammatory or neoplastic processes.Spinal imaging demonstrated degenerative changes, including diffuse cervical disc bulges at multiple levels (C3–C7) and lumbar disc pathology at L4–L5, causing anterior thecal sac indentation but without cord compression or myelomalacia. While the spinal findings were incidental, they were clinically relevant as contributors to chronic pain and potential neurological deficits.The coexistence of disseminated neurocysticercosis with muscular involvement and early degenerative spinal disease highlights the importance of comprehensive evaluation in patients presenting with seizures and persistent headache. Treatment included albendazole-based antiparasitic therapy, corticosteroids to reduce perilesional edema, antiepileptic medications, and conservative management for disc disease.This case underscores the role of MRI in identifying pathognomonic features of cysticercosis, emphasizes the need for systemic evaluation, and demonstrates the significance of recognizing coexisting pathologies for tailored multidisciplinary management.
23 July 2026 in Indian Journal of Radiology and Imaging
Nuclear medicine shows function, not structure. A radioactive tracer is given to the patient and the scanner maps where it goes, and hybrid machines add CT or MRI so that the uptake can be placed on the anatomy. The images are built from a limited number of detected photons, so they are noisy and blurred, and every step from reconstruction to measurement involves correction and estimation. These are tasks to which artificial intelligence is well suited. This chapter follows the examination from injection to report. It explains image reconstruction, attenuation correction and the role of the CT or MRI component, the use of deep learning to lower the dose or shorten the scan, and the measurement of uptake with its main source of error, the partial-volume effect. Applications are reviewed in oncology, cardiology, neurology and bone imaging, followed by radionuclide therapy and dosimetry. Simulations computed for the chapter on artificial phantoms illustrate the main ideas, and the final sections deal with pitfalls and the part played by the technologist.