Ibrahim Alsofyani

Prof. Ibrahim Alsofyani

Electrical and Computer Engineering, Ajou University, Suwon, Gyeonggi, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SLSze Sing Lee
Sze Sing Lee
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
Ibrahim AlsofyaniIbrahim Alsofyani
Ibrahim Alsofyani
Yeongsu BakYeongsu Bak
Yeongsu Bak
JWJing Fang Wong
Jing Fang Wong
The integration of switched-capacitor techniques into multilevel inverters (MLIs) with a dc source string contributes to the boosting of voltage gain, renders it particularly attractive in reducing the number of input dc sources in the series string. However, the recent two-stage MLI topologies suffer from high voltage stress across the backend H-bridge. Addressing this concern, an improved topology, namely the one-switched-capacitor integrated MLI (1SCI-MLI) is proposed in this paper. An extended topology of 1SC-MLI is also established by appropriate incorporation of another switched-capacitor circuit. The two proposed topologies are endowed with voltage boosting capability. They also feature low switch count and low number of dc sources. More importantly, they resolve the high voltage stress problem in the existing counterparts. Their corresponding operational analysis and comparisons with recent MLI topologies are discussed. Simulation and experimental results from a laboratory prototype are presented to validate the effectiveness of the proposed topologies.

22 April 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Ibrahim AlsofyaniIbrahim Alsofyani
Ibrahim Alsofyani
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
Three-level neutral-point-clamped (3L-NPC) voltage source inverters are widely used in many low- and medium-power applications. However, the 3L-NPC inverter has an inheritance issue of the neutral-point (NP) voltage unbalancing due to the deviation of dc-link capacitor voltages causing distortions for the output waveform quality. Generally, discontinuous pulsewidth modulation (DPWM) is used to diminish the stress on power transistors and prolong their lifespan, however; it is not capable of solving the issue of NP voltage unbalancing. Therefore, this article proposes a simple voltage balancing control based on DPWM with a hysteresis NP voltage band. The balancing control method is only activated once the capacitance voltage error exceeds the hysteresis band by generating a momentary offset on the opposite direction of the DPWM offset. In this way, both top and bottom capacitance voltages will converge within a predefined error band. Various hysteresis error bands are investigated by analyzing the power losses, total harmonic distortions, and common mode voltage. The advantages of this proposed method are its simplicity and ease of control while maintaining the features of DPWM. The effectiveness of the proposed method is validated using simulation and experimental results.

13 November 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Ibrahim AlsofyaniIbrahim Alsofyani
Ibrahim Alsofyani
NINik Rumzi Nik Idris
Nik Rumzi Nik Idris
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
The magnitude of hysteresis torque band has a considerable effect on the performance of two-level Direct Torque Control (DTC) of induction machines. The conventional DTC fails at low speed due to the poor flux regulation. In this paper, two dynamic hysteresis torque band (DHTB) strategies for the conventional DTC are proposed to solve this problem by dynamically altering the amplitude of hysteresis torque band based on a flux error range. In this way, the simplicity of DTC algorithm is retained since it only requires a minor modification on its structure. The paper also presents further analysis on flux degradation, particularly the droop in between the flux sectors. In addition, the switching frequency effect of reverse voltage vectors for both DHTB schemes is investigated on the performance of the speed-sensorless DTC drive. The effectiveness of the proposed schemes is confirmed by simulation and experimental validation. Results show a significant enhancement in the flux regulation and dynamic torque response from zero motor speed.

15 December 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Ibrahim AlsofyaniIbrahim Alsofyani
Ibrahim Alsofyani
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
Discrete space vector modulation (DSVM) is employed to synthesize large number of voltage vectors (VVs) to improve the steady-state performance of predictive torque control (PTC). However, enumerating all the VVs in the prediction process increases the computation load of the motor drive. To address this issue, this article proposes a unidirectional VV preselection (UVVP) method for optimizing the performance of DSVM-based PTC of ac motors. The proposed UVVP method divides both voltage space vector diagram (VSVD) and flux space trajectory into twelve 30° based sectors to reduce the impact of candidate VVs with negative effects. At each flux position, the UVVP strategy can restrict the nearest candidate VVs in the 30° based VSVD region within the circular flux trajectory. This is achieved by using the speed direction to avoid the candidate VVs, which are in the same flux sector for reverse flux rotation, hence resulting in significant flux and torque ripple reduction. The main benefit of the proposed method is its simplicity since it only requires the flux sector and speed information as well as it can generate the VV enumerations online while ensuring the reduction of computation burden.

18 December 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Ibrahim AlsofyaniIbrahim Alsofyani
Ibrahim Alsofyani
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
Constant frequency torque controller-based direct torque control (CFTC-DTC) is emerging as a powerful control strategy for a high-performance control of alternating-current motor drives. Compared to DTC, the CFTC-DTC has less torque and flux ripples with a fixed switching frequency. Nevertheless, it has a limitation of the torque-loop bandwidth, as it uses the sampling frequency from a digital signal processor to generate a triangular-based carrier. The switching frequency of the control system is determined by the carrier frequency of the CFTC. The frequency limitation of CFTC leads to sector-flux droop, which causes a distortion in the motor phase current and aggravation in the speed waveform at low speed regions. In this paper, we propose a modification of the frequency carriers of the CFTC-DTC of induction motors to increase the switching frequency and torque loop bandwidth by replacing the triangular-carrier-based waveform with a ramp-carrier-based waveform. The proposed method is verified by simulation and experimental results showing its excellent performances in steady- and transient-state operations.

1 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Ibrahim AlsofyaniIbrahim Alsofyani
Ibrahim Alsofyani
Yeongsu BakYeongsu Bak
Yeongsu Bak
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
In this paper, two simple control methods are proposed for improving direct torque control with a constant frequency torque controller (CFTC-DTC) in induction machines. The CFTC-DTC was initially introduced to reduce torque ripple and achieve constant switching frequency in inverters. However, when compared to the original direct torque control, the CFTC-DTC algorithm suffers from slow torque dynamic response owing to the selection of zero-voltage vectors during torque transient. In addition, when the motor operates at low speed, flux droop occurs at sector transitions, which leads to undesirable current distortions. The problem of flux droop occurs because of short-duty voltage cycles and small radial voltage components at low speeds. This paper has two main contributions: to eliminate zero-voltage vectors during torque dynamics in order to establish a fast torque response in the transient state, and to minimize the flux droop at the sector transitions by applying another triangular carrier and modifying the torque output in order to increase the duty voltage cycles at low motor speeds. A detailed analysis of the problems and proposed methods is presented. Experimental results are provided to validate the effectiveness of both proposed methods.