Ion Pencea

Dr. Ion Pencea

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Applied Surface Science
Verified
Journal Article
Closed access
AMA.A. Matei
A.A. Matei
IPIon Pencea
Ion Pencea
Mihai BranzeiMihai Branzei
Mihai Branzei
DTD.E. Trancă
D.E. Trancă
GŢG. Ţepeş
G. Ţepeş
GSGeorge Stanciu
George Stanciu

1 April 2018 in Applied Surface Science
Verified
Journal Article
Closed access
AMAndreea Maidaniuc
Andreea Maidaniuc
FMFlorin Miculescu
Florin Miculescu
SVStefan Ioan Voicu
Stefan Ioan Voicu
CACorina Andronescu
Corina Andronescu
MMMarian Miculescu
Marian Miculescu
LCLucian Toma Ciocan
Lucian Toma Ciocan

17 August 2015 in Journal of Adhesion Science and Technology
Verified
Journal Article
Closed access
AMA.A. Matei
A.A. Matei
IPIon Pencea
Ion Pencea
GSGeorge Stanciu
George Stanciu
RHRadu Hristu
Radu Hristu
Antoniac IulianAntoniac Iulian
Antoniac Iulian
GSGeorge Stanciu
George Stanciu
A new composite matrix was developed for a cutting tool based on tungsten carbide ligated with cobalt (WC-Co) using sintering technique. The admixtures of niobium carbide, tantalum carbide, and titanium carbide with the WC-Co matrix aim to inhibit the grain growth of WC and to promote covalent bonding at the interface. The modified WC-Co tools were coated with titanium nitride and titanium carbonitride layers by CAE-PVD technique. To substantiate the performances of the new coating-substrate systems, we have performed X-ray diffraction, atomic force microscopy, and scratch test measurements to estimate: phase content, average crystallite size, average texture coefficient, residual stress level, coating thickness, average roughness, square mean root, fractal dimension, cohesive adhesion, and adhesive adhesion. The results enable the in-depth understanding of the coating growth mechanisms and provide an objective evaluation of the coatings adhesion to the new cutting tools matrix. The results provide evidence to support the potential of TiN and TiCN coatings to enhance the working performances of the composite WC-Co cutting tools and to differentiate their properties. TiCN coating is shown to be superior to TiN coating in terms of adhesion and thus represents a better alternative for coating the modified WC-Co composite matrix.

7 January 2023 in Crystals
Verified
Journal Article
Open access
PDF file
AMAlecs Matei
Alecs Matei
RTRamona Nicoleta Turcu
Ramona Nicoleta Turcu
IPIon Pencea
Ion Pencea
EHEugen Herghelegiu
Eugen Herghelegiu
MPMircea Ionuţ Petrescu
Mircea Ionuţ Petrescu
FNFlorentina Niculescu
Florentina Niculescu
The main objective of this work was to assess and compare the structure and mechanical properties of the TiN and TiAlN coatings deposited on a new WC-Co tool using the cathodic arc evaporation vacuum deposition (CAE-PVD) technique. The cutting tool was sintered at high temperature and high pressure using a powder tungsten carbide matrix ligated with cobalt (WC-Co). Powdered grain growth inhibitors (TiC, TaC, and NbC) were admixed into the matrix to enhance its strength and to facilitate the adhesion of the Ti base coatings. Detailed scanning electron microscopy with energy-dispersive spectrometry (SEM-EDS) and X-ray diffraction (XRD) analyses were performed, aiming to substantiate the effectiveness of the inhibitor additions. XRD data were thoroughly exploited to estimate the phase contents, average crystallite sizes (D), coating thicknesses (t), texture coefficients (Thkl), and residual stress levels (σ). Atomic force microscopy (AFM) was used to calculate the average roughness (Ra) and the root mean square (Rq). The microhardness (µHV) was measured using the Vickers method. The TiAlN characteristics (D = 55 nm, t = 3.6 μm, T200 = 1.55, µHV = 3187; σ = −2.8 GPa, Ra = 209 nm, Rq = 268 nm) compared to TiN ones (D = 66 nm, t = 4.3 μm, T111 = 1.52, µHV = 2174; σ = +2.2 GPa, Ra = 246 nm, Rq = 309 nm) substantiate the better adequacy of the TiAlN coating for the WC-Co substrate. The structural features and data on the TiN and TiAlN coatings, the tool type, the different stress kinds exerted into these coatings, and the way of discrimination of the coating adequacy are the novelties addressed in the paper.

19 January 2023 in Journal of Environmental Management
Verified
Journal Article
Open access
IPIon Pencea
Ion Pencea
RTRamona Nicoleta Turcu
Ramona Nicoleta Turcu
APAlina Cristina Popescu-Argeș
Alina Cristina Popescu-Argeș
ATAndrei Lucian Timiș
Andrei Lucian Timiș
APAdrian Priceputu
Adrian Priceputu
FNFlorentina Niculescu
Florentina Niculescu
The scope of this study consists of setting up of an integrated cost-effective sampling & laboratory analyses procedure which delineates sampling, sub-sampling and analytical uncertainties in case of fine-grained extractive waste deposits. This procedure is designed to support the decision makers towards fine-grained waste deposits upcycling and land reclamation. This procedure consists of a balanced replicated sampling design (BRSD) coupled with a three split levels ANOVA data processing. The paper provides the readership with the mathematical backgrounds of the three split level ANOVA analysis (3L-ANOVA) and an Excel algorithm for its implementation. Also, the paper presents an example of implementation of the developed methods in the case of a Romanian iron ore tailings (IOT) old pond. The findings of the paper consist of: a) argues, based on OM, SEM-EDS, XRFS and XRD observations, that classical TOS is ineffective for fine-grained waste deposits; b) BRSD in conjunction with 3L-ANOVA analysis is the only approach fit for reliable characterization of the fine-grained stockpiles; c) sampling uncertainty is the critical factor of the uncertainty budget of the analyte concentration; d) Lilliefors approach is adequate for the hypothesis testing where or not the measurand is normal distributed; e) The outcomes of the BRDSD&3L-ANOVA investigations carried on Teliuc tailings, estimated at circa 5.5* 106 m3, consist mainly of mineral quantification at lot level i.e. quartz ∼54% (±7%), hematite ∼15% (±3%), calcite ∼11% (±3%), MgO 3% (±1%), Al2O3 9% (±2%). The concentrations of some CRMs like Ti, V, Ba, Y, W were found at ACE limits and their associated relative expanded uncertainties overpass 50%. Thus, the expanded uncertainties clearly depict the reliability of acquired data for the decision makers regarding waste valorization. f) The IOT into Teliuc can be upcycled as minerals for cement and ceramic industries as well as for geopolymer manufacture. Also, IOT can be downcycles as filler in road construction and mine closure. Finally, the Teliuc yard can be rehabilitated with zero-waste left behind. The data exactness provided by this procedure can be increased to any desirable level through increasing the number of collected items, but the cost of sampling and analyses increases proportionally. In such circumstances, the posted approach can be tailored at the stakeholder request as to safely underpin the decision to turn finegrained by-products into valuable secondary resources, facilitating a greater circularity of the mining industry.

14 May 2012 in Solid State Phenomena
Verified
Journal Article
Closed access
PDF file
Florin MiculescuFlorin Miculescu
Florin Miculescu
LCLucian Toma Ciocan
Lucian Toma Ciocan
MMMarian Miculescu
Marian Miculescu
AEAdrian Ernuteanu
Adrian Ernuteanu
Antoniac IulianAntoniac Iulian
Antoniac Iulian
IPIon Pencea
Ion Pencea
High concentrations of metals in the natural environment associated with industrial activity and increased migration of metals may cause an increase in the concentration of metals in living organisms, especially in the bone tissue, which reflects their total concentration in the body. Physiological basis for this assessment is based on the fact that the skeleton serves as a major reservoir for ingested heavy metals integrating them into bone matrix during calcification and where they remain until the bone is remodeled or resorbed. Investigations on the bone can be focused on three structural levels: mezostructural, micro, and nanostructural. In this study, we used X-ray fluorescence (XRF) to measure the residual amount of heavy elements in bone particles, obtained by a widely used method. The bones used to perform the experiments were collected from local hospitals, following certain surgical coxofemural prosthesis operations (according to agreed procedures on patient privacy and medical ethics).Studies carried out on samples taken from humans have shown that the variability in bone chemical composition is depending on subject living area, which is essential for understanding the contribution of these factors on bone mass and constitution. Comparing values obtained with concentrations of metals in bones reported by other authors allowed us to conclude that EDPXRF method can be used to assess tissue concentrations of natural elements and the results provide a basis for evaluating metal loading of the human body.