The pathophysiology of the severe course of COVID-19 is multifactorial and not entirely elucidated. However, it is well known that the hyperinflammatory response and cytokine storm are paramount events leading to further complications. In this paper, we investigated the vascular response in the pathophysiology of severe COVID-19 and aimed to identify novel biomarkers predictive of ICU admission. The study group consisted of 210 patients diagnosed with COVID-19 (age range: 18–93; mean ± SD: 57.78 ± 14.16), while the control group consisted of 80 healthy individuals. We assessed the plasma concentrations of various vascular factors using the Luminex technique. Then, we isolated RNA from blood mononuclear cells and performed a bioinformatics analysis investigating various processes related to vascular response, inflammation and angiogenesis. Our results confirmed that severe COVID-19 is associated with vWF/ADAMTS 13 imbalance. High plasma concentrations of VEGFR and low DPP-IV may be potential predictors of ICU admission. SARS-CoV-2 infection impairs angiogenesis, hinders the generation of nitric oxide, and thus impedes vasodilation. The hypercoagulable state develops mainly in the early stages of the disease, which may contribute to the well-established complications of COVID-19.
Background and Objectives: The goal was to evaluate the association of dynamic retinal vessel analysis (DVA) with echocardiographic parameters assessing systolic and diastolic function of the left ventricle in hypertension (HT) patients with preserved left ventricle ejection fraction. Materials and Methods: This observational retrospective study recruited 36 patients with HT and 28 healthy controls. Retinal vessel diameter and reactions to flicker light were examined. Each patient was examined with echocardiography to assess left ventricular systolic and diastolic function. Results: Multivariate analysis revealed that hypertension was an independent factor associated with lower flicker-induced arterial vasodilatation (β = −0.31, p = 0.029). In the HT group, there was a significant positive association between left ventricular ejection fraction and flicker-induced arterial vasodilation (Rs = +0.31, p = 0.007). Additionally, end-diastolic left ventricular diameter negatively correlated with both arterial (Rs = −0.26, p = 0.02) and venous (Rs = −0.27, p = 0.02) flicker responses. Additionally, the echocardiographic characteristics of the left atrium (LA) remodeling in the course of HT, including the area of the LA and its antero-posterior dimension, were both negatively correlated with the arterial flicker response (Rs = −0.34, p = 0.003; Rs = −0.33, p = 0.004, respectively). From tissue Doppler parameters, the left ventricular filling index E/e’ negatively correlated with AVR (arteriovenous ratio) values (Rs = −0.36, p = 0.002). Conclusions: We revealed that systolic and diastolic function of the left ventricle in hypertensive patients is associated with retinal microvascular function.
Background: Endovascular aortic aneurysm repair (EVAR) is considered the gold standard for the treatment of abdominal aortic aneurysms. However, the performance of stent-grafts used during this procedure may be affected by their structural design, particularly in anatomically challenging, tortuous iliac arteries. This study aimed to evaluate the hemodynamic performance of different stent-graft limb designs in an in vitro EVAR simulation using compliant three-dimensional (3D)-printed iliac artery models with controlled angulations. Methods: Four commercially available stent-grafts (Anaconda®, Endurant II®, Treo®, Zenith Spiral-Z®) representing different stent-strut configurations (including O-ring, Z-stent, and spiral designs) were deployed in compliant 3D-printed vascular phantoms simulating severe iliac angulations of 75°, 90°, and 105°. The models were incorporated into a pulsatile flow circuit, and pressure and flow velocity were measured proximally and distally to the angulated segment. Results: Across all tested angulations, the O-ring-based design demonstrated the most favorable hemodynamic performance. In particular, the Anaconda stent-graft showed the smallest pressure loss and the lowest increase in distal flow velocity, especially in the 90° and 105° models. These findings suggest that O-ring-supported structures provide greater flexibility and conformability in severely angulated iliac segments. Conclusions: In this controlled in vitro setting, stent-grafts with O-ring strut morphology better preserved flow conditions than other tested configurations in tortuous anatomy. These results suggest that stent-graft structural design may influence device behavior in challenging iliac anatomy under controlled in vitro conditions. These findings should be considered hypothesis-generating bench data and do not represent direct evidence for clinical device selection.