Scott Nokleby

Prof. Scott Nokleby


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Control Engineering Practice
Verified
Journal Article
Open access
BDBrayden DeBoon
Brayden DeBoon
SNScott Nokleby
Scott Nokleby
CRCarlos Rossa
Carlos Rossa

26 January 2021 in Robotica
Verified
Journal Article
Closed access
PDF file
RBRoger Boudreau
Roger Boudreau
SNScott Nokleby
Scott Nokleby
MGMarise Gallant
Marise Gallant
SUMMARY This paper presents a methodology to obtain the wrench capabilities of a kinematically redundant planar parallel manipulator using a wrench polytope approach. A methodology proposed by others for non-redundant and actuation-redundant manipulators is adapted to a kinematically redundant manipulator. Four wrench capabilities are examined: a pure force analysis, the maximum force for a prescribed moment, the maximum reachable force, and the maximum moment with a prescribed force. The proposed methodology, which finds the exact explicit solution for three of the four wrench capabilities, does not use optimization and is very efficient.

1 December 2024 in Transactions of the Canadian Society for Mechanical Engineering
Verified
Journal Article
Closed access
CBChristopher Baird
Christopher Baird
SNScott Nokleby
Scott Nokleby
This paper presents the development of a proof-of-concept autonomous firefighting robot based on the Spot quadruped robot. Both the payload and software package for the autonomous detection, localization, and extinguishing of a small fire are discussed. A thermal camera is mounted to the front of Spot and a standard ABC fire extinguisher is mounted to the back. The thermal camera is used to autonomously detect fires and the fire extinguisher is used to put out a detected fire. The system was successfully tested at a local fire station in a controlled setting with actual fires. The results of this project have direct application in the area of autonomous first response in complex industrial environments and fire watch applications.

1 March 2022 in Mechanism and Machine Theory
Verified
Journal Article
Closed access
MAMarc Arsenault
Marc Arsenault
RBRoger Boudreau
Roger Boudreau
SNScott Nokleby
Scott Nokleby


11 November 2020 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
BDBrayden M DeBoon
Brayden M DeBoon
RFRyan C. A. Foley
Ryan C. A. Foley
SNScott Nokleby
Scott Nokleby
NDNicholas La Delfa
Nicholas La Delfa
CRCarlos Rossa
Carlos Rossa
The design of rehabilitation devices for patients experiencing musculoskeletal disorders (MSDs) requires a great deal of attention. This article aims to develop a comprehensive model of the upper-limb complex to guide the design of robotic rehabilitation devices that prioritize patient safety, while targeting effective rehabilitative treatment. A 9 degree-of-freedom kinematic model of the upper-limb complex is derived to assess the workspace of a constrained arm as an evaluation method of such devices. Through a novel differential inverse kinematic method accounting for constraints on all joints1820, the model determines the workspaces in which a patient is able to perform rehabilitative tasks and those regions where the patient needs assistance due to joint range limitations resulting from an MSD. Constraints are imposed on each joint by mapping the joint angles to saturation functions, whose joint-space derivative near the physical limitation angles approaches zero. The model Jacobian is reevaluated based on the nonlinearly mapped joint angles, providing a means of compensating for redundancy while guaranteeing feasible inverse kinematic solutions. The method is validated in three scenarios with different constraints on the elbow and palm orientations. By measuring the lengths of arm segments and the range of motion for each joint, the total workspace of a patient experiencing an upper-limb MSD can be compared to a preinjured state. This method determines the locations in which a rehabilitation device must provide assistance to facilitate movement within reachable space that is limited by any joint restrictions resulting from MSDs.