We propose an ischemic stroke detection system with a computer-aided diagnostic ability using a four-step unsupervised feature perception enhancement method. In the first step, known as preprocessing, we use a cubic curve contrast enhancement method to enhance image contrast. In the second step, we use a series of methods to extract the brain tissue image area identified during preprocessing. To detect abnormal regions in the brain images, we propose using an unsupervised region growing algorithm to segment the brain tissue area. The brain is centered on a horizontal line and the white matter of the brain’s inner ring is split into eight regions. In the third step, we use a coinciding regional location method to find the hybrid area of locations where a stroke may have occurred in each cerebral hemisphere. Finally, we make corrections and mark the stroke area with red color. In the experiment, we tested the system on 90 computed tomography (CT) images from 26 patients, and, with the assistance of two radiologists, we proved that our proposed system has computer-aided diagnostic capabilities. Our results show an increased stroke diagnosis sensitivity of 83% in comparison to 31% when radiologists use conventional diagnostic images.
Wearable assistant devices play an important role in daily life for people with disabilities. Those who have hearing impairments may face dangers while walking or driving on the road. The major danger is their inability to hear warning sounds from cars or ambulances. Thus, the aim of this study is to develop a wearable assistant device with edge computing, allowing the hearing impaired to recognize the warning sounds from vehicles on the road. An EfficientNet-based, fuzzy rank-based ensemble model was proposed to classify seven audio sounds, and it was embedded in an Arduino Nano 33 BLE Sense development board. The audio files were obtained from the CREMA-D dataset and the Large-Scale Audio dataset of emergency vehicle sirens on the road, with a total number of 8756 files. The seven audio sounds included four vocalizations and three sirens. The audio signal was converted into a spectrogram by using the short-time Fourier transform for feature extraction. When one of the three sirens was detected, the wearable assistant device presented alarms by vibrating and displaying messages on the OLED panel. The performances of the EfficientNet-based, fuzzy rank-based ensemble model in offline computing achieved an accuracy of 97.1%, precision of 97.79%, sensitivity of 96.8%, and specificity of 97.04%. In edge computing, the results comprised an accuracy of 95.2%, precision of 93.2%, sensitivity of 95.3%, and specificity of 95.1%. Thus, the proposed wearable assistant device has the potential benefit of helping the hearing impaired to avoid traffic accidents.
Breast cancer has the highest incidence among women in Taiwan, which is mainly screened by mammography. When the doctor observes the mammogram and initially judges that the patient has malignant microcalcification (MC) clusters, the patient must undergo needle localization surgical biopsy. However, needle localization surgical biopsy makes the patient painful, and the color of breast tissue and MCs are all white, which makes it difficult for doctors to judge where MCs are clustered immediately. Thus, we use VGG16 to find out breast MC clusters from the image. Moreover, we use Mask RCNN to find MCs from the clusters to remove the noise from the background. Finally, we use Inception V3 to identify the benign and malignant of MC clusters. The accuracy of the cluster classification, MCs labeling and benign and malignant analysis are 93%, 95% and 91%. Furthermore, the precision, specificity and sensitivity of our proposed methods are about 87%, 89% and 90%, respectively. It proved that our system can effectively assist doctors in diagnosing and reduce the burden on patients and medical personnel.
Currently, in terms of reducing the infection risk of the COVID-19 virus spreading all over the world, the development of touchless blood pressure (BP) measurement has potential benefits. The pulse transit time (PTT) has a high relation with BP, which can be measured by electrocardiogram (ECG) and photoplethysmogram (PPG). The ballistocardiogram (BCG) reflects the mechanical vibration (or displacement) caused by the heart contraction/relaxation (or heart beating), which can be measured from multiple degrees of the body. The goal of this study is to develop a cuffless and touchless BP-measurement method based on a commercial weight scale combined with a PPG sensor when measuring body weight. The proposed method was that the PTTBCG-PPGT was extracted from the BCG signal measured by a weight scale, and the PPG signal was measured from the PPG probe placed at the toe. Four PTT models were used to estimate BP. The reference method was the PTTECG-PPGF extracted from the ECG signal and PPG signal measured from the PPG probe placed at the finger. The standard BP was measured by an electronic blood pressure monitor. Twenty subjects were recruited in this study. By the proposed method, the root-mean-square error (ERMS) of estimated systolic blood pressure (SBP) and diastolic blood pressure (DBP) are 6.7 ± 1.60 mmHg and 4.8 ± 1.47 mmHg, respectively. The correlation coefficients, r2, of the proposed model for the SBP and DBP are 0.606 ± 0.142 and 0.284 ± 0.166, respectively. The results show that the proposed method can serve for cuffless and touchless BP measurement.
1 April 2012 in Journal of Discrete Mathematical Sciences and Cryptography
This paper aims to Investigate properties of homomorphisms which preserve some languages. We study the characteristic of maximal codes, maximal hypercodes, maximal prefix codes, primitive words, noncounting languages and left-noncounting languages.
Electronic health (eHealth) is a strategy to improve the physical and mental condition of a human, collecting daily physiological data and information from digital apparatuses. Body weight and blood pressure (BP) are the most popular and important physiological data. The goal of this study is to develop a minimal contact BP measurement method based on a commercial body weight-fat scale, capturing biometrics when users stand on it. The pulse transit time (PTT) is extracted from the ballistocardiogram (BCG) and impedance plethysmogram (IPG), measured by four strain gauges and four footpads of a commercial body weight-fat scale. Cuffless BP measurement using the electrocardiogram (ECG) and photoplethysmogram (PPG) serves as the reference method. The BP measured by a commercial BP monitor is considered the ground truth. Twenty subjects participated in this study. By the proposed model, the root-mean-square errors and correlation coefficients (r2s) of estimated systolic blood pressure and diastolic blood pressure are 7.3 ± 2.1 mmHg and 4.5 ± 1.8 mmHg, and 0.570 ± 0.205 and 0.284 ± 0.166, respectively. This accuracy level achieves the C grade of the corresponding IEEE standard. Thus, the proposed method has the potential benefit for eHealth monitoring in daily application.