Fauzun Fauzun

Dr. Fauzun Fauzun

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2023 in Fluids
Verified
Journal Article
Open access
PDF file
IPIndro Pranoto
Indro Pranoto
MRMuhammad Aulia Rahman
Muhammad Aulia Rahman
CWCahya Dhika Wicaksana
Cahya Dhika Wicaksana
AWAlan Eksi Wibisono
Alan Eksi Wibisono
FFFauzun Fauzun
Fauzun Fauzun
AWArif Widyatama
Arif Widyatama
The trend of miniaturisation in recent decades has led to the development of compact electronic devices. The reduction in the required dimension leads to the exponential rise in the heat flux dissipated from such a system. A proper thermal management system is necessary to keep the temperature of a computer chip’s junction within acceptable limits and maintain its performance. Flow boiling modification using straight fins in microchannels has proven to be an effective passive enhancement of the cooling system. The core interest of this research is figuring out the optimal configuration of the fin shapes and configurations. Hence, it is crucial to gain a comprehensive understanding of the flow boiling phenomenon to establish a more general approach. In this study, the boiling heat transfer performance of fin microchannels with various shapes and dimensions is investigated experimentally. The study has shown that the choice of fin geometry has a significant impact on the thermal performance of a heat transfer system. Specifically, the results indicate that a rectangular cross-section fin performs better than a trapezoidal one with the same fin gap. The rectangular cross-section fin exhibits the highest heat transfer coefficient of 5066.84 W/m2∙K, outperforming the trapezoidal fin in terms of heat transfer capability. As the hydraulic diameter reduces, the thermal boundary layer becomes denser, providing a more distributed saturated region. This leads to the increase in the heat transfer coefficient up to 22.5% and 17.1% for rectangular and trapezoidal fins, respectively. Additionally, the efficiency analysis shows that, albeit increasing the mass flux and reducing the gap increase the average cooling performance, but the pressure drop jumps up to 48%, reducing the efficiency of the heat removal system.

1 January 2023 in Journal of Applied Engineering Science
Verified
Journal Article
Open access
PDF file
FFFauzun Fauzun
Fauzun Fauzun
CYCahyo Wibi Yogiswara
Cahyo Wibi Yogiswara
HAHifni Mukhtar Ariyadi
Hifni Mukhtar Ariyadi
MTMuhammad Salim Taufiqurrahman
Muhammad Salim Taufiqurrahman
ARAldy Franstanata Ritonga
Aldy Franstanata Ritonga
FRFirdausa Retnaning Restu
Firdausa Retnaning Restu
The Indonesian smart hybrid light train is a train under development by the government and will operate in Makassar-Parepare, Indonesia track. The authors conducted a numerical study on CFD to investigate the air flow distribution inside the air conditioning ducting and the air velocity and air temperature distribution on Motor Engine and Compartment (MEC) car to achieve the passenger comfort criteria based on the regulation standard of Indonesia Minister of Transportation Number 69 of 2019. This study was conducted by simulating 5 variations of air barriers height inside the supply ducts. The input of air into the ducting has the parameters of mass flow rate, static temperature, static pressure, and density with the values of 1 kg/s, 20 °C, 1 atm, and 1.2 kg/m 3 , respectively. The simulation results show that variation E is the best design which generated the average air velocity and air temperature distribution in the executive passenger cabin with the values of 0.25 m/s and 21.91 °C, respectively. Meanwhile, the other 4 variations did not satisfy the standard. The results also show that the ducting geometry can accommodate the air temperature difference on the MEC car that does not exceed 1.5 °C and the air supply is sufficient from the air conditioner unit to the driver room.

1 January 2025 in Journal of Applied Engineering Science
Verified
Journal Article
Open access
PDF file
FFFauzun Fauzun
Fauzun Fauzun
FMFaizal Arif Mohamad
Faizal Arif Mohamad
KAKevin Ostaputra Achmad
Kevin Ostaputra Achmad
AIArsyadani Tsalisul Ilham
Arsyadani Tsalisul Ilham
WCWibi Yogiswara Cahyo
Wibi Yogiswara Cahyo
Kereta Cepat Merah Putih (KCMP) was a high-speed train developed by the Indonesian government to enhance intercity travel. A key focus of this development was the HVAC system within the passenger cabin, essential for ensuring passenger comfort. This study investigated the impact of air barrier placement and air flow direction angles (45°, 90°, and 135°) on airspeed and temperature distribution in the cabin. Using CFD simulations with ANSYS Fluent, six variations were tested to determine the optimal configuration. The results identified variation model 3, which employed an air barrier at the top of the ducting system and omitted the use of blocking angles for the air flow direction of the supply diffuser, as the most effective in achieving optimal airspeed and temperature distribution. Following the simulation, experimental measurements were conducted on a scaled-down model of variation 3. Measurements were taken at six sample planes in the supply duct and five in the supply duct diffuser, applying the duct traversing method (ISO 3966) with 25 measurement points per sample plane. The experimental results were then compared with the simulation data to ensure consistency in volumetric flow rate, flow velocity, and air pressure drop parameters. Additionally, comparisons were made with similar trains, measuring air velocity and temperature distribution within their passenger cabins. The findings confirmed that the performance of variation model 3 in the CFD simulation aligned with the scaled-down experimental results, demonstrating consistency in both tests and comparisons.

24 July 2026 in Eng
Verified
Journal Article
Open access
PDF file
FFFauzun Fauzun
Fauzun Fauzun
MHMuhammad Arkan Febian Hermada
Muhammad Arkan Febian Hermada
FAFakhreza Areli
Fakhreza Areli
AIArsyadani Tsalisul Ilham
Arsyadani Tsalisul Ilham
FSFariz Galang Nusantara Putra Setiawan
Fariz Galang Nusantara Putra Setiawan
CYCahyo Wibi Yogiswara
Cahyo Wibi Yogiswara
Unlike many previous high-speed train Heating, Ventilation, and Air Conditioning (HVAC) studies that combined numerical and experimental analyses within the cabin, this study evaluates the supply duct independently, offering a more targeted assessment of internal duct airflow and thermal performance. The research comprised two numerical stages and an experimental validation. The first stage evaluated four ducting geometry variations and identified the ducting system arrangement of 20 supply diffusers with a 45° air grille blocking angle as optimal for the Kereta Cepat Merah Putih (KCMP) case, keeping air velocity within the thermal comfort range for all simulated passengers. This geometry was then manufactured as a full-scale prototype and assessed in a second numerical stage against experimental measurements. The air velocity yielded a mean absolute deviation (MAD) of 0.57 m/s and a relative mean deviation (RMD) of 34.22%, while the air temperature showed an MAD of 2.13 °C and an RMD of 8.16% at duct planes, and 0.80 °C and 3.06% at duct outlets. These results demonstrate that the proposed approach of testing the supply duct independently of the cabin is able to capture the general internal duct airflow trends, even though, particularly for the temperature parameters, a large temperature discrepancy occurs at downstream locations traced to three factors: uncontrolled ambient thermal conditions in a large-scale indoor facility, simplified thermal boundary conditions in the simulation, and additional uncertainty from the non-standardised temperature measurement method. Nonetheless, it offers a promising preliminary reference for HVAC system development, prior to integrated carbody testing, although further method refinements are still required to strengthen the reliability of this approach.

1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
FFFauzun Fauzun
Fauzun Fauzun
DGDhimas Thufeil Ghifari
Dhimas Thufeil Ghifari
Cold storage is one of the important post-harvest treatments for horticultural commodities. One of the cold storage methods that are commonly used is air-forced cooling. Reducing the temperature of the commodity and the surrounding air can inhibit the damage caused by the growth of fungi, as well as the respiration rate of the product itself. The geometry, layout of shelves, evaporators and fans affect the distribution of temperature and airflow inside the cold storage. The study begins with a three-dimensional cold storage geometry and then simplified with CAD software, which is then carried out by meshing the geometry and define the geometry domain with ANSYS Fluent. The simulation uses CFD, which the results are analyzed to know the temperature distribution and airflow inside the cold storage. The numerical simulation begins with the design simulation and then compared with the reference literature. Furthermore, the geometry models are varied using a single deflector and corner baffle, which has a radius of 0.75 m and 0.9 m. The simulation results are compared to see the effect to cooling performance of cold storage. The simulation results show that single deflector variations cause the cooling time of commodity faster, while the corner baffle variations do not have a significant effect to the cooling time. Radius variations with larger dimensions can accelerate the process of temperature uniformity inside cold storage compared to smaller dimensions. Radius variations with larger dimensions can accelerate the process of temperature uniformity in cold storage compared to smaller dimensions.