Indro Pranoto

Dr. Indro Pranoto

Gadjah Mada University, Yogyakarta, Indonesia
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in Applied Thermal Engineering
Verified
Journal Article
Closed access
IPIndro Pranoto
Indro Pranoto
KLK.C. Leong
K.C. Leong

1 September 2012 in Applied Thermal Engineering
Verified
Journal Article
Closed access
IPIndro Pranoto
Indro Pranoto
KLK.C. Leong
K.C. Leong
LJL.W. Jin
L.W. Jin

1 October 2011 in Applied Thermal Engineering
Verified
Journal Article
Closed access
LJL.W. Jin
L.W. Jin
KLK.C. Leong
K.C. Leong
IPIndro Pranoto
Indro Pranoto

2 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
IPIndro Pranoto
Indro Pranoto
MRMuhammad Aulia Rahman
Muhammad Aulia Rahman
PMPradhana A. P. Mahardhika
Pradhana A. P. Mahardhika
In this paper, an experimental study investigating the effect of the geometrical shape of the circular and rectangular pin fins on the heat transfer performance and the boiling phenomenon is presented. A pool boiling experiment in the HFE-7100 dielectric working fluid under atmospheric pressure was conducted. Boiling curves and boiling heat transfer coefficients of different test cases were plotted to evaluate the heat transfer performance as well as the captured images of the boiling phenomenon on the test samples. Two quantities, flow resistance and wetted perimeter, were calculated to understand the behaviour of the boiling physics due to variation of fin geometrical shape and, hence, their effect on the heat transfer performance. It was found that the cooling performance of the rectangular pin fins was higher than that of the circular pin fins, despite having a slightly higher flow resistance of 4% and 7%, respectively. This is believed to be the result of the longer wetted perimeter up to 27%, whereby the nucleation site has a higher probability of generating more bubbles in the same boiling surface area. For the tested modified boiling surface with 196 and 144 pin fins, the average heat transfer performances were found to have differences of up to 3.54 and 1.58 times larger, respectively.

8 July 2022 in Fluids
Verified
Journal Article
Open access
PDF file
IPIndro Pranoto
Indro Pranoto
MRMuhammad Aulia Rahman
Muhammad Aulia Rahman
JWJoko Waluyo
Joko Waluyo
Pool boiling surface modification by pin fin array has demonstrated a practical but effective cooling enhancement. Whilst the main challenge is to determine the best configuration of the pin fin dimensions and positioning, it is known that the result varies among the working conditions. To obtain a more general formulation, it is utterly vital to obtain a deep understanding of the pool boiling mechanism during the phase-change process. This study aimed to analyze the role of pin fin array configuration on the pool boiling phenomenon by generating visualization and non-dimensional analysis. The results illustrated three different regimes occurring during the boiling process: natural convection, isolated bubble, and merged bubble. For all regimes, the average heat transfer performance was enhanced as the fin gap rose to 17% and 63% for circular and rectangular pin fins, respectively. Furthermore, Grashof (Gr) and Bond (Bo) numbers were calculated to quantitatively describe the effect on the bubble dynamics. From these approaches, it was found that the insulated bubble regime provides a better means of cooling by around 60% due to the better bubble dynamics.

1 June 2011 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
LJL. W. Jin
L. W. Jin
KLK. C. Leong
K. C. Leong
IPIndro Pranoto
Indro Pranoto
HLH. Y. Li
H. Y. Li
JCJ. C. Chai
J. C. Chai
This paper presents an experimental study of heat transfer in a pool boiling evaporator with porous insert. Porous graphite foams were structured into cubic block and straight fin shapes and tested with FC-72 and HFE-7000 coolants with the objective of maximizing the heat transfer in a pool boiling configuration. A two-phase thermosyphon facility was developed to investigate the system’s performance using graphite foams of block and fin structures. The effects of foam configuration, working fluid type, and coolant filling volume on pool boiling heat transfer were analyzed. The results showed that the coolant filling volume has negligible effect on cooling performance. On the other hand, the thermosyphon performance is significantly affected by the coolant properties and the configuration of the porous graphite foam. A comparison of the Bond numbers obtained for FC-72 and HFE-7000 indicates that the bubbles have to overcome higher surface tension forces before departing the foam surface in HFE-7000. Meanwhile, the effect of the foam configuration on the boiling heat transfer performance implies that a properly designed geometry of the porous graphite foam will lead to significant enhancement of the evaporation process in a thermosyphon system.