Xianfeng Yang

Dr. Xianfeng Yang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
KZKaijia Zhang
Kaijia Zhang
LLLan Li
Lan Li
LYLongfei Yang
Longfei Yang
JSJianping Shi
Jianping Shi
LZLiya Zhu
Liya Zhu
QJQing Jiang
Qing Jiang
The objective of this study is to investigate the biomechanics on the knee components caused by degenerative and radial meniscal tears and resultant meniscectomy. A detailed finite element model of the knee joint with bones, cartilages, menisci and main ligaments was constructed from a combination of computed tomography and magnetic resonance images. Degenerative and radial tears of both menisci and resultant medial meniscectomy were used and two different kinds of simulations, the vertical and the anterior load, mimicking the static stance and slight flexion simulations, were applied on the model. The compressive and shear stress and meniscus extrusion were evaluated and compared. Generally, both degenerative and radial tears lead to increased peak compressive and shear stress of both cartilages and menisci and large meniscus extrusion, and the medial meniscal tear induced larger value of stress and extrusion than the lateral meniscal tear. The peak stress and meniscus extrusion further elevated after the medial meniscus meniscectomy. Distribution of stress was shifted from the intact hemi joint to the injured hemi joint with either medial or lateral meniscal tear. Our finite element model provides a realistic three-dimensional knee model to investigate the effects of degenerative and radial meniscal tears and resultant meniscectomy on the stress distribution of the knee. The stress was increased in meniscal tears and increased significantly when meniscectomy was performed. Increased meniscus extrusion may explain the mechanism for higher stress on the components of the knee. Meniscal tears are the most common damage associated to the menisci, and meniscectomy is often performed to relieve the pain and instability of the knee. The results of our study indicated increased stress on cartilages and menisci, which may lead to early onset of osteoarthritis. This may guide surgeons to preserve more of the meniscus when performing meniscectomy.

25 July 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
KZKaijia Zhang
Kaijia Zhang
LLLan Li
Lan Li
LYLongfei Yang
Longfei Yang
JSJianping Shi
Jianping Shi
Liya ZhuLiya Zhu
Liya Zhu
QJQing Jiang
Qing Jiang
Meniscal horns are important structures of meniscus, and longitudinal tears of these places could significantly change the load distribution among the knee joint. Few studies concerned the stress concentrated on bones, which may induce the osteonecrosis of subchondral bone. The goal of this study was to construct a finite element (FE) model with high fidelity of the knee joint and evaluate the biomechanical changes of load distribution of components after longitudinal tears of the horns of meniscus. Computed tomography and magnetic resonance images were used to develop the FE model, and two different kinds of simulations, the vertical and the anterior load, mimicking the static stance and slight flexion simulations, were applied after longitudinal tears of the horns of meniscus. Significantly elevated peak compressive and shear stress was observed on the menisci, cartilages, and subchondral bones, and enlarged meniscus extrusion was noticed. Between all the four types of longitudinal tears investigated in this study, longitudinal tears at the posterior horn of the medial meniscus were found to be the most significant. These findings showed that longitudinal tears of the meniscal horns lead to increased magnitude and changed distribution of stress and indicated the important role of posterior horn of medial meniscus. This may contribute to the mechanism between meniscal tears and spontaneous subchondral bone osteonecrosis.

26 June 2022 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
JLJie Li
Jie Li
KQKun Qian
Kun Qian
JLJinyong Liu
Jinyong Liu
ZHZhijun Huang
Zhijun Huang
YZYuchen Zhang
Yuchen Zhang
QJQing Jiang
Qing Jiang
Meniscus tear is a common problem in sports trauma, and its imaging diagnosis mainly relies on MRI. To improve the diagnostic accuracy and efficiency, a deep learning model was employed in this study and the identification efficiency was evaluated. Standard knee MRI images from 924 individual patients were used to complete the training, validation and testing processes. Mask regional convolutional neural network (R–CNN) was used to build the deep learning network structure, and ResNet50 was adopted to develop the backbone network. The deep learning model was trained and validated with a dataset containing 504 and 220 patients, respectively. Internal testing was performed based on a dataset of 200 patients, and 180 patients from 8 hospitals were regarded as an external dataset for model validation. Additionally, 40 patients who were diagnosed by the arthroscopic surgery were enrolled as the final test dataset. After training and validation, the deep learning model effectively recognized healthy and injured menisci. Average precision for the three types of menisci (healthy, torn and degenerated menisci) ranged from 68% to 80%. Diagnostic accuracy for healthy, torn and degenerated menisci was 87.50%, 86.96%, and 84.78%, respectively. Validation results from external dataset demonstrated that the accuracy of diagnosing torn and intact meniscus tear through 3.0T MRI images was higher than 80%, while the accuracy verified by arthroscopic surgery was 87.50%. Mask R–CNN effectively identified and diagnosed meniscal injuries, especially for tears that occurred in different parts of the meniscus. The recognition ability was admirable, and the diagnostic accuracy could be further improved with increased training sample size. Therefore, this deep learning model showed great potential in diagnosing meniscus injuries. Deep learning model exerted unique effect in terms of reducing doctors’ workload and improving diagnostic accuracy. Injured and healthy menisci could be more accurately identified and classified based on training and learning datasets. This model could also distinguish torn from degenerated menisci, making it an effective tool for MRI-assisted diagnosis of meniscus injuries in clinical practice.

18 June 2018 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
LLLan Li
Lan Li
LYLongfei Yang
Longfei Yang
FYFei Yu
Fei Yu
JSJianping Shi
Jianping Shi
Liya ZhuLiya Zhu
Liya Zhu
QJQing Jiang
Qing Jiang
To explore the therapeutic effect and the biomechanical mechanism of 3D printing individualized heel cup in treating of plantar heel pain. The clinical effect was evaluated by plantar pressure analysis and pain assessment in participants. Its biomechanical mechanism of protecting the plantar heel was explored using finite element simulation. The individualized heel cup could support and protect the osseous structure and soft tissue of plantar heel while walking and jogging, as well as significantly reduce the self-reported pain after being worn for 4 weeks. The nylon heel cup could alter the load concentration of the heel as well as decrease the load affected on plantar fascia and calcaneus bone. It also provided an obvious support for heel pad. To summarize, the 3D printed individualized heel cup can be used as an effective method for the treatment of plantar heel pain.

1 October 2018 in Annals of Translational Medicine
Verified
Journal Article
Closed access
PDF file
TXTianwei Xia
Tianwei Xia
FYFei Yu
Fei Yu
KZKaijia Zhang
Kaijia Zhang
ZWZongfang Wu
Zongfang Wu
DSDongquan Shi
Dongquan Shi
QJQing Jiang
Qing Jiang
Background: Intraarticular injection of the mesenchymal stem cells (MSCs) has shown to be successful for treating osteoarthritis (OA). Nevertheless, many studies have been focusing on autologous MSCs. The following study investigates the safety and effectiveness of intraarticular injection of allogenic MSCs in a pig OA model. Methods: Superparamagnetic iron oxide (SPIO) nanoparticles were labelled with bone marrow-derived mesenchymal stem cells (BM-MSCs) to allow cells tracking using magnetic resonance imaging (MRI). A pig OA model was established by bilateral medial meniscectomy. Next, SPIO-BM-MSCs were injected into the right knee, while the left knee was left untreated. MRI and radiography were used to assess the degree of OA and to evaluate the effectiveness of allogenic MSCs. Hematoxylin and eosin (H&E), safranin-o fast green staining, toluidine blue, and immunohistochemical staining were used to evaluate the therapeutic effect of the injections. Results: At concentration of ≤20 µg/mL, SPIO caused no toxicity to BM-MSCs. Four weeks after surgery, OA changes were observed on MRI scan. The SPIO labeled BM-MSCs were found moving towards the impaired part of the cartilage 8 to 24 h after injections. In addition, no significant differences between the right side (therapeutic side) and the left side (untreated side) were observed following histological and immunohistochemistry analysis. Conclusions: The suitable concentration of SPIO for labelling BMSCs was 20 µg/mL, while the allogenic MSCs could move towards and accumulate around the impaired cartilage. No significant difference was found between treatment and control group.

1 February 2021 in Annals of Palliative Medicine
Verified
Journal Article
Open access
PDF file
SWShujuan Wei
Shujuan Wei
LLLan Li
Lan Li
JSJianping Shi
Jianping Shi
HLHuixin Liang
Huixin Liang
XYXianfeng Yang
Xianfeng Yang
Self-compassion mediates the perfectionism and depression link on Chinese undergraduates Shujuan Wei, Lan Li, Jianping Shi, Huixin Liang, Xianfeng Yang