Maria Romaguera

Ms. Maria Romaguera

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2025 in Journal of Drug Delivery Science and Technology
Verified
Journal Article
Open access
MFMaria João Faria
Maria João Faria
MRMaria Romaguera
Maria Romaguera
HGHugo Manuel Castro Gonçalves
Hugo Manuel Castro Gonçalves
Artur RibeiroArtur Ribeiro
Artur Ribeiro
CRClarisse Ribeiro
Clarisse Ribeiro
Marlene LúcioMarlene Lúcio
Marlene Lúcio

23 January 2026 in Journal of Optometry
Verified
Journal Article
Open access
MRMaria Romaguera
Maria Romaguera
GVGonzalo Valdes-Soria
Gonzalo Valdes-Soria
LSLaura Ximena Sierra-Buitrago
Laura Ximena Sierra-Buitrago
CCCarlos Carpena-Torres
Carlos Carpena-Torres
juan gonzalo carracedo rodriguezjuan gonzalo carracedo rodriguez
juan gonzalo carracedo rodriguez
To evaluate the in vitro measurement of central thickness (CT) in soft contact lenses using two commercial optical coherence tomography (OCT) systems by analyzing their repeatability and agreement. A randomized, controlled, investigator-masked trial was conducted using 120 soft contact lenses made from eight different materials. Three examiners measured the CT of the soft contact lenses using two commercial OCT systems with a spherical support marked for correct lens centration. One system was a swept-source OCT, and the other a spectral-domain OCT. Intra- and inter-examiner repeatability were assessed. Comparisons between the OCT systems and the electronic thickness gauge, considered the gold standard, were analyzed. Agreement between the two OCT systems was evaluated using Bland-Altman plots. Both OCT systems showed a 95% confidence interval for intra-examiner repeatability of <10.0 µm for most materials. Inter-examiner repeatability was worse than intra-examiner repeatability, exceeding 10.0 µm in some materials. The mean differences between the OCT devices and the electronic thickness gauge were <10 µm. Swept-source OCT provided slightly lower CT values than spectral-domain OCT, although most differences were within ± 10 µm. Both OCT systems demonstrate good repeatability and strong agreement with the electronic thickness gauge for measuring the central thickness of soft contact lenses, and can be used interchangeably. These findings support their use as a viable alternative in lens development, manufacturing, and quality control.

25 June 2026 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MRMaria Romaguera
Maria Romaguera
Maria Vivero-LopezMaria Vivero-Lopez
Maria Vivero-Lopez
AIAffiong Iyire
Affiong Iyire
RGRaquel Gil-Cazorla
Raquel Gil-Cazorla
FAFrancisco Arnalich-Montiel
Francisco Arnalich-Montiel
juan gonzalo carracedo rodriguezjuan gonzalo carracedo rodriguez
juan gonzalo carracedo rodriguez
Background/Objectives: Corneal epithelial defects and ulcers remain a significant clinical challenge, often leading to vision impairment and requiring prolonged treatment. In this context, topical insulin has recently gained attention in ophthalmic research. However, conventional eye drops suffer from short residence time and poor bioavailability. To overcome these limitations, the present study evaluates, for the first time in vitro, multiple commercially available soft contact lenses as sustained insulin delivery platforms, analyzing how protein loading influences the essential physicochemical and optical properties of these materials. Methods: The physicochemical properties of eight different commercially available soft contact lens materials, including light transmittance, wettability, and central thickness, were examined before and after insulin loading via a soaking method. Loading efficiency and in vitro release profiles were assessed over time. Corneal cytotoxicity and permeability were evaluated using a human epithelial cell-based model (HCE-2). Results: Among the eight commercial materials screened, Nesofilcon A, Stenfilcon A, and Delefilcon A were selected due to their superior physicochemical performance after insulin loading. At initial concentrations of 1750 and 875 μg/mL, drug loading efficiency reached maximum values of up to 69.3% and 63.1%, with cumulative release values reaching up to 32.4% and 55.1% after 24 h, respectively. Permeability studies confirmed effective insulin diffusion across the HCE-2 cell layer, while cell viability assays indicated no significant cytotoxicity at the lower loading concentration. Conclusions: Insulin-loaded commercial soft contact lenses represent a promising drug–device combination product for the management of persistent epithelial defects and refractory corneal ulcers. These in vitro findings suggest that this approach may enhance drug performance by prolonging residence time and improving corneal bioavailability, while maintaining essential lens properties. However, further in vivo and clinical studies are required to confirm these potential benefits and establish therapeutic efficacy for the management of persistent epithelial defects.