30 December 2020 in Digital Diagnostics
ГАГомболевский Виктор Александрович
Гомболевский Виктор Александрович
+4
With the ongoing COVID-19 pandemic decreasing availability of polymerase chain reaction with reverse transcription and the snowballing growth of medical imaging, especially the number of chest computed tomography (CT) scans being performed, methods to augment and automate the image analysis, increasing productivity and minimizing human error are of particular importance. The creation of high-quality datasets is essential for the development and validation of artificial intelligence algorithms. Such technologies have sufficient accuracy in diagnosing COVID-19 in medical imaging. The presented large-scale dataset contains anonymized human CT scans with COVID-19 features as well as normal studies. Some studies were tagged by radiologists using binary pixel masks of regions of interest (e.g., characteristic areas of consolidation and ground-glass opacities). CT data were acquired between March 1, 2020, and April 25, 2020, and provided by municipal hospitals in Moscow, Russia. The presented dataset is licensed under Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported (CC BY-NC-ND 3.0).
1 January 2022 in Russian Journal of Preventive Medicine
Неоднократно описана практическая ценность компьютерной томографии (КТ) органов грудной клетки для диагностики пациентов с подозрением на коронавирусную инфекцию (COVID-19). В условиях высокой загруженности во время пандемии врачи-рентгенологи испытывают нехватку времени для интерпретации результатов исследований. Использование технологий искусственного интеллекта (ИИ) может повлиять на длительность формирования протокола описания КТ-исследований. ЦЕЛЬ ИССЛЕДОВАНИЯ Оценить влияние алгоритма ИИ на скорость описания результатов КТ органов грудной клетки при подозрении на COVID-19 в стационарном звене городского здравоохранения. МАТЕРИАЛ И МЕТОДЫ Проведено ретроспективное исследование, протокол зарегистрирован в ClinicalTrials.gov (NCT04489992). Исследование выполнено на основе данных пациентов, прошедших КТ органов грудной клетки в период с 08.04.20 по 01.12.20 в 105 медицинских организациях стационарного звена городского здравоохранения. КТ органов грудной клетки проводили по стандартным протоколам сканирования. Врачи-рентгенологи анализировали исследования с помощью ИИ-сервиса «Гамма Мультивокс Ковирус» и без него. Формирование протоколов медицинских заключений проведено в Едином радиологическом информационном сервисе в составе Единой медицинской информационно-аналитической системы Москвы. РЕЗУЛЬТАТЫ Без применения ИИ проанализированы 3133 КТ-исследований с признаками COVID-19-ассоциированной пневмонии (1-я группа), с использованием ИИ — 63 379 (2-я группа). Медианная длительность описаний в 1-й и 2-й группах составила 103,0 и 46,0 мин соответственно. Анализ длительности интерпретации врачом-рентгенологом результатов КТ органов грудной клетки до и после внедрения ИИ выявил статистически значимые различия (p<0,0001). Средняя длительность описания КТ органов грудной клетки при использовании ИИ уменьшилась на 29,4%. ЗАКЛЮЧЕНИЕ Внедрение технологии ИИ, направленной на диагностику изменений в легких при COVID-19 по данным КТ органов грудной клетки, в практическую работу отделений лучевой диагностики стационарного звена городского здравоохранения сокращает время подготовки протокола описания врачами-рентгенологами.
12 July 2023 in Digital Diagnostics
Competencies in statistical data processing are becoming increasingly important for modern scientists. The apparent advantages of open-source software for statistical analysis are its accessibility and adaptability. The programming language and the corresponding software R, available as a minimalistic console interface or a complete development environment RStudio/Posit, have the widest possibilities among free solutions. We present a practical guide for comparing two groups using the software R. This study compares the effective doses of standard computed tomography with low-dose computed tomography for COVID-19 patients. The practical guide summarizes theoretical approaches to medical data processing and recommendations for correctly formulating research tasks and selecting optimal statistical analysis methods. The main goal of the practical guide is to introduce the reader to the Posit interface and the basic functionality of the R language by using a practical example of treating a real medical problem. The presented material can be useful as an introduction to statistical analysis using the programming language R.
14 July 2022 in Digital Diagnostics
ГАГомболевский Виктор Александрович
Гомболевский Виктор Александрович
+1
BACKGROUND: The increased frequency of chest computed tomography utilization in the fight against COVID-19 has made usage of low-dose computed tomography necessary to reduce the radiation dose while preserving diagnostic quality. However, in the published literature, there were no data on the effect of body mass index on low-dose computed tomography accuracy in patients with COVID-19. AIM: To assess the effect of patient body mass index on the level of agreement between radiologists interpreting standard-dose computed tomography and low-dose computed tomography in COVID-19-associated pneumonia using visual semiquantitative CT 04 scale. MATERIALS AND METHODS: In this retrospective multicenter study, each participant underwent two consecutive chest scans at a single visit using standard-dose and low-dose protocols. Standard-dose and low-dose computed tomography with pulmonary and soft tissue kernels were interpreted using a visual semiquantitative CT 04 grading system. Data for each protocol were grouped by body mass index value (threshold value for pathology was equal to 25 kg/m2). Agreement was calculated based on binary and weighted classifications. One-way ANOVA analysis of variance was used to assess the presence of statistically significant differences in the mean for the groups. RESULTS: Two hundred thirty patients met the established inclusion criteria for the study. The experts processed 4 studies for each patient: standard-dose and low-dose computed tomography with pulmonary and soft tissue kernels. The proportion of normal-weight patients was 31% (71 subjects), and the samples median body mass index was 27.5 (18.3; 48.3) kg/m2. There were no statistically significant differences in intergroup pairwise comparisons for both the binary and weighted classifications (p values were 0.09 and 0.12, respectively). The group of overweight patients was further subdivided according to the degrees of obesity; however, the results were invariant to this division (no statistically significant differences: for the most different body mass index groups normal and 3rd degree obesity p-value 0.17). CONCLUSION: Body mass index does not affect chest standard-dose and low-dose computed tomography interpretation in COVID-19 using the visual semiquantitative CT 04 grading system.