Luc Pockele

Dr. Luc Pockele


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2017 in Energies
Verified
Journal Article
Open access
PDF file
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
GEGiuseppe Emmi
Giuseppe Emmi
SGSamantha Graci
Samantha Graci
MCMichele De Carli
Michele De Carli
MCMatteo Cultrera
Matteo Cultrera
Adriana BernardiAdriana Bernardi
Adriana Bernardi
The design phase of ground source heat pump systems is an extremely important one as many of the decisions made at that time can affect the system’s energy performance as well as installation and operating costs. The current study examined the interpretation of thermal response testing measurements used to evaluate the equivalent ground thermal conductivity and thus to design the system. All the measurements were taken at the same geological site located in Molinella, Bologna (Italy) where a variety of borehole heat exchangers (BHEs) had been installed and investigated within the project Cheap-GSHPs (Cheap and efficient application of reliable Ground Source Heat exchangers and Pumps) of the European Union’s Horizon 2020 research and innovation program. The measurements were initially analyzed in accordance with the common interpretation based on the first-order approximation of the solution for the infinite line source model and then by utilizing the complete solutions of both the infinite line and cylinder source models. An inverse numerical approach based on a detailed model that considers the current geometry of the BHE and the axial heat transfer as well as the effect of weather on the ground surface was also used. Study findings revealed that the best result was generally obtained using the inverse numerical interpretation.

17 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
DQDavide Quaggiotto
Davide Quaggiotto
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
GEGiuseppe Emmi
Giuseppe Emmi
MCMichele De Carli
Michele De Carli
LPLuc Pockele
Luc Pockele
Adriana BernardiAdriana Bernardi
Adriana Bernardi
In this study, the thermal behavior of the coaxial and double U borehole heat exchangers was investigated using numerical simulations in both the long- and short-term. As a reference for borehole heat exchanger specifications, the existing coaxial and double U probes of a geothermal heat pump installed within the Horizon 2020 research project named “Cheap GSHPs” were considered. Nine years of simulations revealed that when borehole heat exchangers are subjected to a balanced thermal load, and intermittent operating modes of the ground source heat pump system are set, the coaxial pipes’ configuration provides better thermal performance due to the higher thermal capacitance of the heat-carrier fluid and the lower borehole thermal resistance. The analysis was conducted considering two different types of ground with different thermal conductivity values. As result, the more conductive ground type highlights the higher yield of the coaxial probe.

28 April 2012 in Journal of Environmental Science and Engineering B
Verified
Journal Article
Open access
Adriana BernardiAdriana Bernardi
Adriana Bernardi
FBFrancesca Becherini
Francesca Becherini
LPLuc Pockele
Luc Pockele
SGSandro De Grandi
Sandro De Grandi

29 July 2026 in Clean Technologies
Verified
Journal Article
Open access
PDF file
SFStefania Fiameni
Stefania Fiameni
FVFrancesca Visentin
Francesca Visentin
ABAdriana Bernardi
Adriana Bernardi
NMNicola Mutinelli
Nicola Mutinelli
SBSimone Battiston
Simone Battiston
Maria  LosurdoMaria Losurdo
Maria Losurdo
Global decarbonization represents one of the defining challenges of the 21st century. Geothermal energy offers a robust alternative for reducing fossil fuel dependency for both residential and industrial heating and cooling. While shallow geothermal systems are versatile and high-performing, comprehensive Life Cycle Assessments (LCA) remain scarce in the literature. This study evaluates the environmental impact of the manufacturing and installation processes of next-generation coaxial probes featuring a galvanized steel outer tube and an internal polyethylene pipe. The LCA identifies material composition as the primary environmental driver: steel production accounts for 41% of the total impact, while the hot-dip galvanization process contributes 30%, significantly affecting the “climate change” and the “resource use” categories. A comparative LCA with conventional double U-tube installations shows similar overall environmental impacts. A sensitivity analysis on the coaxial probes was conducted to explore potential mitigation strategies aimed at reducing the associated environmental impacts, providing indications for sustainable eco-design. The LCA results demonstrate that optimizing the design, specifically by reducing the steel quantity in the coaxial outer tube and avoiding the zinc coating process, results in a 34% reduction in total environmental impact, confirming that LCA is a fundamental tool for supporting the environmental sustainability of developing technologies.